Laboratory demonstration of a prozone-like effect in HRP2-detecting malaria rapid diagnostic tests: implications for clinical management

BACKGROUND: Malaria rapid diagnostic tests (RDTs) are now widely used for prompt on-site diagnosis in remote endemic areas where reliable microscopy is absent. Aberrant results, whereby negative test results occur at high parasite densities, have been variously reported for over a decade and have le...

Descripción completa

Detalles Bibliográficos
Autores principales: Luchavez, Jennifer, Baker, Joanne, Alcantara, Sheila, Belizario, Vicente, Cheng, Qin, McCarthy, James S, Bell, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214175/
https://www.ncbi.nlm.nih.gov/pubmed/21957869
http://dx.doi.org/10.1186/1475-2875-10-286
_version_ 1782216215698079744
author Luchavez, Jennifer
Baker, Joanne
Alcantara, Sheila
Belizario, Vicente
Cheng, Qin
McCarthy, James S
Bell, David
author_facet Luchavez, Jennifer
Baker, Joanne
Alcantara, Sheila
Belizario, Vicente
Cheng, Qin
McCarthy, James S
Bell, David
author_sort Luchavez, Jennifer
collection PubMed
description BACKGROUND: Malaria rapid diagnostic tests (RDTs) are now widely used for prompt on-site diagnosis in remote endemic areas where reliable microscopy is absent. Aberrant results, whereby negative test results occur at high parasite densities, have been variously reported for over a decade and have led to questions regarding the reliability of the tests in clinical use. METHODS: In the first trial, serial dilutions of recombinant HRP2 antigen were tested on an HRP2-detectiing RDT. In a second trial, serial dilutions of culture-derived Plasmodium falciparum parasites were tested against three HRP2-detecting RDTs. RESULTS: A prozone-like effect occurred in RDTs at a high concentration of the target antigen, histidine-rich protein-2 (above 15,000 ng/ml), a level that corresponds to more than 312000 parasites per μL. Similar results were noted on three RDT products using dilutions of cultured parasites up to a parasite density of 25%. While reduced line intensity was observed, no false negative results occurred. CONCLUSIONS: These results suggest that false-negative malaria RDT results will rarely occur due to a prozone-like effect in high-density infections, and other causes are more likely. However, RDT line intensity is poorly indicative of parasite density in high-density infections and RDTs should, therefore, not be considered quantitative. Immediate management of suspected severe malaria should rely on clinical assessment or microscopy. Evaluation against high concentrations of antigen should be considered in malaria RDT product development and lot-release testing, to ensure that very weak or false negative results will not occur at antigen concentrations that might be seen clinically.
format Online
Article
Text
id pubmed-3214175
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-32141752011-11-12 Laboratory demonstration of a prozone-like effect in HRP2-detecting malaria rapid diagnostic tests: implications for clinical management Luchavez, Jennifer Baker, Joanne Alcantara, Sheila Belizario, Vicente Cheng, Qin McCarthy, James S Bell, David Malar J Research BACKGROUND: Malaria rapid diagnostic tests (RDTs) are now widely used for prompt on-site diagnosis in remote endemic areas where reliable microscopy is absent. Aberrant results, whereby negative test results occur at high parasite densities, have been variously reported for over a decade and have led to questions regarding the reliability of the tests in clinical use. METHODS: In the first trial, serial dilutions of recombinant HRP2 antigen were tested on an HRP2-detectiing RDT. In a second trial, serial dilutions of culture-derived Plasmodium falciparum parasites were tested against three HRP2-detecting RDTs. RESULTS: A prozone-like effect occurred in RDTs at a high concentration of the target antigen, histidine-rich protein-2 (above 15,000 ng/ml), a level that corresponds to more than 312000 parasites per μL. Similar results were noted on three RDT products using dilutions of cultured parasites up to a parasite density of 25%. While reduced line intensity was observed, no false negative results occurred. CONCLUSIONS: These results suggest that false-negative malaria RDT results will rarely occur due to a prozone-like effect in high-density infections, and other causes are more likely. However, RDT line intensity is poorly indicative of parasite density in high-density infections and RDTs should, therefore, not be considered quantitative. Immediate management of suspected severe malaria should rely on clinical assessment or microscopy. Evaluation against high concentrations of antigen should be considered in malaria RDT product development and lot-release testing, to ensure that very weak or false negative results will not occur at antigen concentrations that might be seen clinically. BioMed Central 2011-09-29 /pmc/articles/PMC3214175/ /pubmed/21957869 http://dx.doi.org/10.1186/1475-2875-10-286 Text en Copyright ©2011 Luchavez et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Luchavez, Jennifer
Baker, Joanne
Alcantara, Sheila
Belizario, Vicente
Cheng, Qin
McCarthy, James S
Bell, David
Laboratory demonstration of a prozone-like effect in HRP2-detecting malaria rapid diagnostic tests: implications for clinical management
title Laboratory demonstration of a prozone-like effect in HRP2-detecting malaria rapid diagnostic tests: implications for clinical management
title_full Laboratory demonstration of a prozone-like effect in HRP2-detecting malaria rapid diagnostic tests: implications for clinical management
title_fullStr Laboratory demonstration of a prozone-like effect in HRP2-detecting malaria rapid diagnostic tests: implications for clinical management
title_full_unstemmed Laboratory demonstration of a prozone-like effect in HRP2-detecting malaria rapid diagnostic tests: implications for clinical management
title_short Laboratory demonstration of a prozone-like effect in HRP2-detecting malaria rapid diagnostic tests: implications for clinical management
title_sort laboratory demonstration of a prozone-like effect in hrp2-detecting malaria rapid diagnostic tests: implications for clinical management
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214175/
https://www.ncbi.nlm.nih.gov/pubmed/21957869
http://dx.doi.org/10.1186/1475-2875-10-286
work_keys_str_mv AT luchavezjennifer laboratorydemonstrationofaprozonelikeeffectinhrp2detectingmalariarapiddiagnostictestsimplicationsforclinicalmanagement
AT bakerjoanne laboratorydemonstrationofaprozonelikeeffectinhrp2detectingmalariarapiddiagnostictestsimplicationsforclinicalmanagement
AT alcantarasheila laboratorydemonstrationofaprozonelikeeffectinhrp2detectingmalariarapiddiagnostictestsimplicationsforclinicalmanagement
AT belizariovicente laboratorydemonstrationofaprozonelikeeffectinhrp2detectingmalariarapiddiagnostictestsimplicationsforclinicalmanagement
AT chengqin laboratorydemonstrationofaprozonelikeeffectinhrp2detectingmalariarapiddiagnostictestsimplicationsforclinicalmanagement
AT mccarthyjamess laboratorydemonstrationofaprozonelikeeffectinhrp2detectingmalariarapiddiagnostictestsimplicationsforclinicalmanagement
AT belldavid laboratorydemonstrationofaprozonelikeeffectinhrp2detectingmalariarapiddiagnostictestsimplicationsforclinicalmanagement