Cargando…
Reverse Transrectal Stapling Technique Using the EEA Stapler: An Alternative Approach in Difficult Reversal of Hartmann’s Procedure
The introduction of circular end-to-end stapling devices (CEEA OR EEA stapler) into colorectal surgery have revolutionised anastomotic techniques. The EEA stapler is generally regarded as an instrument that is safe, reliable, and simple to operate. Despite it’s popularity, very little information is...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214281/ https://www.ncbi.nlm.nih.gov/pubmed/22091338 http://dx.doi.org/10.4103/2006-8808.73618 |
_version_ | 1782216227594174464 |
---|---|
author | Zachariah, Sanoop K. |
author_facet | Zachariah, Sanoop K. |
author_sort | Zachariah, Sanoop K. |
collection | PubMed |
description | The introduction of circular end-to-end stapling devices (CEEA OR EEA stapler) into colorectal surgery have revolutionised anastomotic techniques. The EEA stapler is generally regarded as an instrument that is safe, reliable, and simple to operate. Despite it’s popularity, very little information is available regarding the technical difficulties encountered during surgery. The routine technique to perform an end-to-end circular colonic anastomosis is to introduce the instrument distally through the anus (transrectal/transanal approach) and attach it to the anvil which is purse stringed at the distal end of the proximal bowel to be anastomosed. Two cases of reversal of Hartmann’s procedure for perforated diverticulitis are described in the present study, where difficulty was experienced while using the EEA stapler in the routine method. Hence, an alternative reverse technique which was used is presented. |
format | Online Article Text |
id | pubmed-3214281 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Medknow Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-32142812011-11-16 Reverse Transrectal Stapling Technique Using the EEA Stapler: An Alternative Approach in Difficult Reversal of Hartmann’s Procedure Zachariah, Sanoop K. J Surg Tech Case Rep Case Report The introduction of circular end-to-end stapling devices (CEEA OR EEA stapler) into colorectal surgery have revolutionised anastomotic techniques. The EEA stapler is generally regarded as an instrument that is safe, reliable, and simple to operate. Despite it’s popularity, very little information is available regarding the technical difficulties encountered during surgery. The routine technique to perform an end-to-end circular colonic anastomosis is to introduce the instrument distally through the anus (transrectal/transanal approach) and attach it to the anvil which is purse stringed at the distal end of the proximal bowel to be anastomosed. Two cases of reversal of Hartmann’s procedure for perforated diverticulitis are described in the present study, where difficulty was experienced while using the EEA stapler in the routine method. Hence, an alternative reverse technique which was used is presented. Medknow Publications 2010 /pmc/articles/PMC3214281/ /pubmed/22091338 http://dx.doi.org/10.4103/2006-8808.73618 Text en © Journal of Surgical Technique and Case Report http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Zachariah, Sanoop K. Reverse Transrectal Stapling Technique Using the EEA Stapler: An Alternative Approach in Difficult Reversal of Hartmann’s Procedure |
title | Reverse Transrectal Stapling Technique Using the EEA Stapler: An Alternative Approach in Difficult Reversal of Hartmann’s Procedure |
title_full | Reverse Transrectal Stapling Technique Using the EEA Stapler: An Alternative Approach in Difficult Reversal of Hartmann’s Procedure |
title_fullStr | Reverse Transrectal Stapling Technique Using the EEA Stapler: An Alternative Approach in Difficult Reversal of Hartmann’s Procedure |
title_full_unstemmed | Reverse Transrectal Stapling Technique Using the EEA Stapler: An Alternative Approach in Difficult Reversal of Hartmann’s Procedure |
title_short | Reverse Transrectal Stapling Technique Using the EEA Stapler: An Alternative Approach in Difficult Reversal of Hartmann’s Procedure |
title_sort | reverse transrectal stapling technique using the eea stapler: an alternative approach in difficult reversal of hartmann’s procedure |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214281/ https://www.ncbi.nlm.nih.gov/pubmed/22091338 http://dx.doi.org/10.4103/2006-8808.73618 |
work_keys_str_mv | AT zachariahsanoopk reversetransrectalstaplingtechniqueusingtheeeastapleranalternativeapproachindifficultreversalofhartmannsprocedure |