Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique

AIM: To evaluate the clinical outcomes of Keraring segment implantation in patients with post- laser-assisted in situ keratomileusis (LASIK) ectasia, using a mechanical implantation technique. MATERIALS AND METHODS: Twelve eyes of 10 patients with post-LASIK ectasia were enrolled. Intracorneal ring...

Descripción completa

Detalles Bibliográficos
Autores principales: Tunc, Zeki, Helvacioglu, Firat, Sencan, Sadik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214413/
https://www.ncbi.nlm.nih.gov/pubmed/22011487
http://dx.doi.org/10.4103/0301-4738.86310
_version_ 1782216257802600448
author Tunc, Zeki
Helvacioglu, Firat
Sencan, Sadik
author_facet Tunc, Zeki
Helvacioglu, Firat
Sencan, Sadik
author_sort Tunc, Zeki
collection PubMed
description AIM: To evaluate the clinical outcomes of Keraring segment implantation in patients with post- laser-assisted in situ keratomileusis (LASIK) ectasia, using a mechanical implantation technique. MATERIALS AND METHODS: Twelve eyes of 10 patients with post-LASIK ectasia were enrolled. Intracorneal ring segments (ICRS) were implanted after dissection of the tunnel using Tunc's specially designed dissector under suction. A complete ophthalmic examination was performed, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent, keratometric (K) readings, inferosuperior asymmetry index (ISAI), and ultrasound pachymetry. All 3, 6, and 12-month follow-ups were completed, and statistical analysis was performed. RESULTS: The mean preoperative UDVA for all eyes was 1.28 ± 0.59 logMAR. At 12 months, the mean UDVA was 0.36 ± 0.19 logarithm of the Minimum Angle of Resolution (logMAR) (P=0.002), and the mean preoperative CDVA was 0.58 ± 0.3 logMAR, which improved to 0.15 ± 0.12 (P=0.002) at 1 year. There was a significant reduction in cylindrical refractive and spherical equivalent refractive error from –5.29 ± 2.47 diopters (D) and –5.54 ± 5.04 D preoperatively to –1.47 ± 0.71 D and –0.74 ± 1.07 D (P=0.001, P=0.002), respectively, at 1 year. In the same period, the mean K- readings improved from 47.93 ± 4.84 D to 40.87 ± 2.36 D (P=0.002), and the mean ISAI improved from 5.34 ± 3.05 to 2.37 ± 1.68 (P=0.003). No significant changes in mean central corneal thickness were observed postoperatively. There were no major complications during or after surgery. CONCLUSION: ICRS implantation using a unique mechanical dissection technique is a safe and effective treatment for post-LASIK ectasia. All parameters showed improvement at 1-year follow-up.
format Online
Article
Text
id pubmed-3214413
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-32144132011-11-16 Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique Tunc, Zeki Helvacioglu, Firat Sencan, Sadik Indian J Ophthalmol Original Article AIM: To evaluate the clinical outcomes of Keraring segment implantation in patients with post- laser-assisted in situ keratomileusis (LASIK) ectasia, using a mechanical implantation technique. MATERIALS AND METHODS: Twelve eyes of 10 patients with post-LASIK ectasia were enrolled. Intracorneal ring segments (ICRS) were implanted after dissection of the tunnel using Tunc's specially designed dissector under suction. A complete ophthalmic examination was performed, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent, keratometric (K) readings, inferosuperior asymmetry index (ISAI), and ultrasound pachymetry. All 3, 6, and 12-month follow-ups were completed, and statistical analysis was performed. RESULTS: The mean preoperative UDVA for all eyes was 1.28 ± 0.59 logMAR. At 12 months, the mean UDVA was 0.36 ± 0.19 logarithm of the Minimum Angle of Resolution (logMAR) (P=0.002), and the mean preoperative CDVA was 0.58 ± 0.3 logMAR, which improved to 0.15 ± 0.12 (P=0.002) at 1 year. There was a significant reduction in cylindrical refractive and spherical equivalent refractive error from –5.29 ± 2.47 diopters (D) and –5.54 ± 5.04 D preoperatively to –1.47 ± 0.71 D and –0.74 ± 1.07 D (P=0.001, P=0.002), respectively, at 1 year. In the same period, the mean K- readings improved from 47.93 ± 4.84 D to 40.87 ± 2.36 D (P=0.002), and the mean ISAI improved from 5.34 ± 3.05 to 2.37 ± 1.68 (P=0.003). No significant changes in mean central corneal thickness were observed postoperatively. There were no major complications during or after surgery. CONCLUSION: ICRS implantation using a unique mechanical dissection technique is a safe and effective treatment for post-LASIK ectasia. All parameters showed improvement at 1-year follow-up. Medknow Publications 2011 /pmc/articles/PMC3214413/ /pubmed/22011487 http://dx.doi.org/10.4103/0301-4738.86310 Text en Copyright: © Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Tunc, Zeki
Helvacioglu, Firat
Sencan, Sadik
Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique
title Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique
title_full Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique
title_fullStr Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique
title_full_unstemmed Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique
title_short Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique
title_sort evaluation of intrastromal corneal ring segments for treatment of post-lasik ectasia patients with a mechanical implantation technique
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214413/
https://www.ncbi.nlm.nih.gov/pubmed/22011487
http://dx.doi.org/10.4103/0301-4738.86310
work_keys_str_mv AT tunczeki evaluationofintrastromalcornealringsegmentsfortreatmentofpostlasikectasiapatientswithamechanicalimplantationtechnique
AT helvacioglufirat evaluationofintrastromalcornealringsegmentsfortreatmentofpostlasikectasiapatientswithamechanicalimplantationtechnique
AT sencansadik evaluationofintrastromalcornealringsegmentsfortreatmentofpostlasikectasiapatientswithamechanicalimplantationtechnique