Cargando…
Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique
AIM: To evaluate the clinical outcomes of Keraring segment implantation in patients with post- laser-assisted in situ keratomileusis (LASIK) ectasia, using a mechanical implantation technique. MATERIALS AND METHODS: Twelve eyes of 10 patients with post-LASIK ectasia were enrolled. Intracorneal ring...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214413/ https://www.ncbi.nlm.nih.gov/pubmed/22011487 http://dx.doi.org/10.4103/0301-4738.86310 |
_version_ | 1782216257802600448 |
---|---|
author | Tunc, Zeki Helvacioglu, Firat Sencan, Sadik |
author_facet | Tunc, Zeki Helvacioglu, Firat Sencan, Sadik |
author_sort | Tunc, Zeki |
collection | PubMed |
description | AIM: To evaluate the clinical outcomes of Keraring segment implantation in patients with post- laser-assisted in situ keratomileusis (LASIK) ectasia, using a mechanical implantation technique. MATERIALS AND METHODS: Twelve eyes of 10 patients with post-LASIK ectasia were enrolled. Intracorneal ring segments (ICRS) were implanted after dissection of the tunnel using Tunc's specially designed dissector under suction. A complete ophthalmic examination was performed, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent, keratometric (K) readings, inferosuperior asymmetry index (ISAI), and ultrasound pachymetry. All 3, 6, and 12-month follow-ups were completed, and statistical analysis was performed. RESULTS: The mean preoperative UDVA for all eyes was 1.28 ± 0.59 logMAR. At 12 months, the mean UDVA was 0.36 ± 0.19 logarithm of the Minimum Angle of Resolution (logMAR) (P=0.002), and the mean preoperative CDVA was 0.58 ± 0.3 logMAR, which improved to 0.15 ± 0.12 (P=0.002) at 1 year. There was a significant reduction in cylindrical refractive and spherical equivalent refractive error from –5.29 ± 2.47 diopters (D) and –5.54 ± 5.04 D preoperatively to –1.47 ± 0.71 D and –0.74 ± 1.07 D (P=0.001, P=0.002), respectively, at 1 year. In the same period, the mean K- readings improved from 47.93 ± 4.84 D to 40.87 ± 2.36 D (P=0.002), and the mean ISAI improved from 5.34 ± 3.05 to 2.37 ± 1.68 (P=0.003). No significant changes in mean central corneal thickness were observed postoperatively. There were no major complications during or after surgery. CONCLUSION: ICRS implantation using a unique mechanical dissection technique is a safe and effective treatment for post-LASIK ectasia. All parameters showed improvement at 1-year follow-up. |
format | Online Article Text |
id | pubmed-3214413 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Medknow Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-32144132011-11-16 Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique Tunc, Zeki Helvacioglu, Firat Sencan, Sadik Indian J Ophthalmol Original Article AIM: To evaluate the clinical outcomes of Keraring segment implantation in patients with post- laser-assisted in situ keratomileusis (LASIK) ectasia, using a mechanical implantation technique. MATERIALS AND METHODS: Twelve eyes of 10 patients with post-LASIK ectasia were enrolled. Intracorneal ring segments (ICRS) were implanted after dissection of the tunnel using Tunc's specially designed dissector under suction. A complete ophthalmic examination was performed, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent, keratometric (K) readings, inferosuperior asymmetry index (ISAI), and ultrasound pachymetry. All 3, 6, and 12-month follow-ups were completed, and statistical analysis was performed. RESULTS: The mean preoperative UDVA for all eyes was 1.28 ± 0.59 logMAR. At 12 months, the mean UDVA was 0.36 ± 0.19 logarithm of the Minimum Angle of Resolution (logMAR) (P=0.002), and the mean preoperative CDVA was 0.58 ± 0.3 logMAR, which improved to 0.15 ± 0.12 (P=0.002) at 1 year. There was a significant reduction in cylindrical refractive and spherical equivalent refractive error from –5.29 ± 2.47 diopters (D) and –5.54 ± 5.04 D preoperatively to –1.47 ± 0.71 D and –0.74 ± 1.07 D (P=0.001, P=0.002), respectively, at 1 year. In the same period, the mean K- readings improved from 47.93 ± 4.84 D to 40.87 ± 2.36 D (P=0.002), and the mean ISAI improved from 5.34 ± 3.05 to 2.37 ± 1.68 (P=0.003). No significant changes in mean central corneal thickness were observed postoperatively. There were no major complications during or after surgery. CONCLUSION: ICRS implantation using a unique mechanical dissection technique is a safe and effective treatment for post-LASIK ectasia. All parameters showed improvement at 1-year follow-up. Medknow Publications 2011 /pmc/articles/PMC3214413/ /pubmed/22011487 http://dx.doi.org/10.4103/0301-4738.86310 Text en Copyright: © Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Tunc, Zeki Helvacioglu, Firat Sencan, Sadik Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique |
title | Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique |
title_full | Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique |
title_fullStr | Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique |
title_full_unstemmed | Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique |
title_short | Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique |
title_sort | evaluation of intrastromal corneal ring segments for treatment of post-lasik ectasia patients with a mechanical implantation technique |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214413/ https://www.ncbi.nlm.nih.gov/pubmed/22011487 http://dx.doi.org/10.4103/0301-4738.86310 |
work_keys_str_mv | AT tunczeki evaluationofintrastromalcornealringsegmentsfortreatmentofpostlasikectasiapatientswithamechanicalimplantationtechnique AT helvacioglufirat evaluationofintrastromalcornealringsegmentsfortreatmentofpostlasikectasiapatientswithamechanicalimplantationtechnique AT sencansadik evaluationofintrastromalcornealringsegmentsfortreatmentofpostlasikectasiapatientswithamechanicalimplantationtechnique |