Cargando…
Measurement of femoral head penetration in polyethylene using a 3-dimensional CT-scan technique
BACKGROUND: Current techniques for measuring in vivo polyethylene wear suffer from a range of problems, resulting in an unacceptable lack of repeatability and/or insufficient accuracy when they are used to measure the low wear rates associated with new, highly crosslinked polyethylene. We describe a...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Informa Healthcare
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214744/ https://www.ncbi.nlm.nih.gov/pubmed/20860445 http://dx.doi.org/10.3109/17453674.2010.519163 |
_version_ | 1782216308594573312 |
---|---|
author | Vandenbussche, Eric Saffarini, Mohammed Hansen, Ulrich Taillieu, Fabienne Mutschler, Céline Augereau, Bernard Gregory, Thomas M |
author_facet | Vandenbussche, Eric Saffarini, Mohammed Hansen, Ulrich Taillieu, Fabienne Mutschler, Céline Augereau, Bernard Gregory, Thomas M |
author_sort | Vandenbussche, Eric |
collection | PubMed |
description | BACKGROUND: Current techniques for measuring in vivo polyethylene wear suffer from a range of problems, resulting in an unacceptable lack of repeatability and/or insufficient accuracy when they are used to measure the low wear rates associated with new, highly crosslinked polyethylene. We describe an improved CT method for measurement of 3D femoral head penetration in PE acetabular cups that has sufficient accuracy and repeatability to allow assessment of the wear potential of modern implants. METHOD: The accuracy and repeatability of the CT-scan method was determined by blindly repeating measurements on a precisely calibrated 28-mm prosthetic head and by comparing them with direct metrological measurements on 10 acetabular specimens with in vitro wear from machining, and on 8 explanted acetabular specimens with in vivo wear. RESULTS: The intra- and interobserver errors in femoral head diameter were 0.036 mm (SD 0.044) and 0.050 mm (SD 0.022), respectively. CT estimated femoral head penetration in both all-poly and metal-backed acetabular components with accuracy ranging from 0.009 to 0.245 mm (mean 0.080; SD 0.067). INTERPRETATION: We found that the CT method is rapid, is accurate, and has repeatability and ease of availability. Using a slice thickness of 0.0625 mm, this method can detect wear—and also the threshold for the wear rate that causes osteolysis—much earlier than previous methods. |
format | Online Article Text |
id | pubmed-3214744 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Informa Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-32147442011-11-25 Measurement of femoral head penetration in polyethylene using a 3-dimensional CT-scan technique Vandenbussche, Eric Saffarini, Mohammed Hansen, Ulrich Taillieu, Fabienne Mutschler, Céline Augereau, Bernard Gregory, Thomas M Acta Orthop Research Article BACKGROUND: Current techniques for measuring in vivo polyethylene wear suffer from a range of problems, resulting in an unacceptable lack of repeatability and/or insufficient accuracy when they are used to measure the low wear rates associated with new, highly crosslinked polyethylene. We describe an improved CT method for measurement of 3D femoral head penetration in PE acetabular cups that has sufficient accuracy and repeatability to allow assessment of the wear potential of modern implants. METHOD: The accuracy and repeatability of the CT-scan method was determined by blindly repeating measurements on a precisely calibrated 28-mm prosthetic head and by comparing them with direct metrological measurements on 10 acetabular specimens with in vitro wear from machining, and on 8 explanted acetabular specimens with in vivo wear. RESULTS: The intra- and interobserver errors in femoral head diameter were 0.036 mm (SD 0.044) and 0.050 mm (SD 0.022), respectively. CT estimated femoral head penetration in both all-poly and metal-backed acetabular components with accuracy ranging from 0.009 to 0.245 mm (mean 0.080; SD 0.067). INTERPRETATION: We found that the CT method is rapid, is accurate, and has repeatability and ease of availability. Using a slice thickness of 0.0625 mm, this method can detect wear—and also the threshold for the wear rate that causes osteolysis—much earlier than previous methods. Informa Healthcare 2010-10 2010-10-08 /pmc/articles/PMC3214744/ /pubmed/20860445 http://dx.doi.org/10.3109/17453674.2010.519163 Text en Copyright: © Nordic Orthopaedic Federation http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited. |
spellingShingle | Research Article Vandenbussche, Eric Saffarini, Mohammed Hansen, Ulrich Taillieu, Fabienne Mutschler, Céline Augereau, Bernard Gregory, Thomas M Measurement of femoral head penetration in polyethylene using a 3-dimensional CT-scan technique |
title | Measurement of femoral head penetration in polyethylene using a 3-dimensional CT-scan technique |
title_full | Measurement of femoral head penetration in polyethylene using a 3-dimensional CT-scan technique |
title_fullStr | Measurement of femoral head penetration in polyethylene using a 3-dimensional CT-scan technique |
title_full_unstemmed | Measurement of femoral head penetration in polyethylene using a 3-dimensional CT-scan technique |
title_short | Measurement of femoral head penetration in polyethylene using a 3-dimensional CT-scan technique |
title_sort | measurement of femoral head penetration in polyethylene using a 3-dimensional ct-scan technique |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214744/ https://www.ncbi.nlm.nih.gov/pubmed/20860445 http://dx.doi.org/10.3109/17453674.2010.519163 |
work_keys_str_mv | AT vandenbusscheeric measurementoffemoralheadpenetrationinpolyethyleneusinga3dimensionalctscantechnique AT saffarinimohammed measurementoffemoralheadpenetrationinpolyethyleneusinga3dimensionalctscantechnique AT hansenulrich measurementoffemoralheadpenetrationinpolyethyleneusinga3dimensionalctscantechnique AT taillieufabienne measurementoffemoralheadpenetrationinpolyethyleneusinga3dimensionalctscantechnique AT mutschlerceline measurementoffemoralheadpenetrationinpolyethyleneusinga3dimensionalctscantechnique AT augereaubernard measurementoffemoralheadpenetrationinpolyethyleneusinga3dimensionalctscantechnique AT gregorythomasm measurementoffemoralheadpenetrationinpolyethyleneusinga3dimensionalctscantechnique |