Cargando…
Z-Shaped Microcatheter Tip Shaping for Embolization of Aneurysms at the Proximal A1 Segment of the Anterior Cerebral Artery: A Technical Note
Embolization of an aneurysm at the proximal A1 segment of the anterior cerebral artery (ACA) is technically challenging. We treated four consecutive patients with unruptured aneurysms at the proximal portion of the A1 segment of the ACA. We tested various microcatheter tip shapes before we successfu...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Interventional Neuroradiology
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214811/ https://www.ncbi.nlm.nih.gov/pubmed/22125756 http://dx.doi.org/10.5469/neuroint.2011.6.2.95 |
_version_ | 1782216322955870208 |
---|---|
author | Lee, Ha Young Ahn, Jae Sung Suh, Dae Chul Lee, Deok Hee |
author_facet | Lee, Ha Young Ahn, Jae Sung Suh, Dae Chul Lee, Deok Hee |
author_sort | Lee, Ha Young |
collection | PubMed |
description | Embolization of an aneurysm at the proximal A1 segment of the anterior cerebral artery (ACA) is technically challenging. We treated four consecutive patients with unruptured aneurysms at the proximal portion of the A1 segment of the ACA. We tested various microcatheter tip shapes before we successfully embolized a lesion with a zigzag-shaped microcatheter tip, which was made by steam shaping. The shape of this microcatheter tip resembled the letter "Z", had a relatively long distal straight segment and was helpful in prompt catheterization of the aneurysm sac and stable placement of the catheter and delivery of coils. |
format | Online Article Text |
id | pubmed-3214811 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Korean Society of Interventional Neuroradiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-32148112011-11-28 Z-Shaped Microcatheter Tip Shaping for Embolization of Aneurysms at the Proximal A1 Segment of the Anterior Cerebral Artery: A Technical Note Lee, Ha Young Ahn, Jae Sung Suh, Dae Chul Lee, Deok Hee Neurointervention Technical Note Embolization of an aneurysm at the proximal A1 segment of the anterior cerebral artery (ACA) is technically challenging. We treated four consecutive patients with unruptured aneurysms at the proximal portion of the A1 segment of the ACA. We tested various microcatheter tip shapes before we successfully embolized a lesion with a zigzag-shaped microcatheter tip, which was made by steam shaping. The shape of this microcatheter tip resembled the letter "Z", had a relatively long distal straight segment and was helpful in prompt catheterization of the aneurysm sac and stable placement of the catheter and delivery of coils. Korean Society of Interventional Neuroradiology 2011-08 2011-08-31 /pmc/articles/PMC3214811/ /pubmed/22125756 http://dx.doi.org/10.5469/neuroint.2011.6.2.95 Text en Copyright © 2011 Korean Society of Interventional Neuroradiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Technical Note Lee, Ha Young Ahn, Jae Sung Suh, Dae Chul Lee, Deok Hee Z-Shaped Microcatheter Tip Shaping for Embolization of Aneurysms at the Proximal A1 Segment of the Anterior Cerebral Artery: A Technical Note |
title | Z-Shaped Microcatheter Tip Shaping for Embolization of Aneurysms at the Proximal A1 Segment of the Anterior Cerebral Artery: A Technical Note |
title_full | Z-Shaped Microcatheter Tip Shaping for Embolization of Aneurysms at the Proximal A1 Segment of the Anterior Cerebral Artery: A Technical Note |
title_fullStr | Z-Shaped Microcatheter Tip Shaping for Embolization of Aneurysms at the Proximal A1 Segment of the Anterior Cerebral Artery: A Technical Note |
title_full_unstemmed | Z-Shaped Microcatheter Tip Shaping for Embolization of Aneurysms at the Proximal A1 Segment of the Anterior Cerebral Artery: A Technical Note |
title_short | Z-Shaped Microcatheter Tip Shaping for Embolization of Aneurysms at the Proximal A1 Segment of the Anterior Cerebral Artery: A Technical Note |
title_sort | z-shaped microcatheter tip shaping for embolization of aneurysms at the proximal a1 segment of the anterior cerebral artery: a technical note |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214811/ https://www.ncbi.nlm.nih.gov/pubmed/22125756 http://dx.doi.org/10.5469/neuroint.2011.6.2.95 |
work_keys_str_mv | AT leehayoung zshapedmicrocathetertipshapingforembolizationofaneurysmsattheproximala1segmentoftheanteriorcerebralarteryatechnicalnote AT ahnjaesung zshapedmicrocathetertipshapingforembolizationofaneurysmsattheproximala1segmentoftheanteriorcerebralarteryatechnicalnote AT suhdaechul zshapedmicrocathetertipshapingforembolizationofaneurysmsattheproximala1segmentoftheanteriorcerebralarteryatechnicalnote AT leedeokhee zshapedmicrocathetertipshapingforembolizationofaneurysmsattheproximala1segmentoftheanteriorcerebralarteryatechnicalnote |