Validation of Tikhonov adaptively regularized gamma variate fitting with 24-h plasma clearance in cirrhotic patients with ascites
PURPOSE: The aim was to compare late-time extrapolation of plasma clearance (CL) from Tikhonov adaptively regularized gamma variate fitting (Tk-GV) and from mono-exponential (E1) fitting. METHODS: Ten (51)Cr-ethylenediaminetetraacetic acid bolus IV studies in adults—8 with ascites—assessed for liver...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3218286/ https://www.ncbi.nlm.nih.gov/pubmed/21881927 http://dx.doi.org/10.1007/s00259-011-1887-9 |
_version_ | 1782216684877119488 |
---|---|
author | Wesolowski, Carl Adam Ling, Lin Xirouchakis, Elias Burniston, Maria T. Puetter, Richard C. Babyn, Paul S. Giamalis, Ioannis G. Burroughs, Andrew K. |
author_facet | Wesolowski, Carl Adam Ling, Lin Xirouchakis, Elias Burniston, Maria T. Puetter, Richard C. Babyn, Paul S. Giamalis, Ioannis G. Burroughs, Andrew K. |
author_sort | Wesolowski, Carl Adam |
collection | PubMed |
description | PURPOSE: The aim was to compare late-time extrapolation of plasma clearance (CL) from Tikhonov adaptively regularized gamma variate fitting (Tk-GV) and from mono-exponential (E1) fitting. METHODS: Ten (51)Cr-ethylenediaminetetraacetic acid bolus IV studies in adults—8 with ascites—assessed for liver transplantation, with 12–16 plasma samples drawn from 5-min to 24-h, were fit with Tk-GV and E1 models and CL results were compared using Passing-Bablok fitting. RESULTS: The 24-h CL(Tk-GV) values ranged from 11.4 to 79.7 ml/min. Linear regression of 4- versus 24-h CL(Tk-GV) yielded no significant departure from a slope of 1, whereas the 4- versus 24-h CL(E1) slope, 1.56, was significantly increased. For CL(Tk-GV-24-h) versus CL(E1-24-h), there was a biased slope and intercept (0.85, 5.97 ml/min). Moreover, the quality of fitting of 24-h data was significantly better for Tk-GV than for E1, as follows. For 10 logarithm of concentration curves, higher r values were obtained for each Tk-GV fit (median 0.998) than for its corresponding E1 fit (median 0.965), with p < 0.0001 (paired t-test of z-statistics from Fisher r-z transformations). The E1 fit quality degraded with increasing V/W [volume of distribution (l) per kg body weight, p = 0.003]. However, Tk-GV fit quality versus V/W was uncorrelated (p = 0.8). CONCLUSION: CL(E1) values were dependent on sample time and the quality of fit was poor and degraded with increasing ascites, consistent with current opinion that CL(E1) is contraindicated in ascitic patients. CL(Tk-GV) was relatively more accurate and the good quality of fit was unaffected by ascites. CL(Tk-GV) was the preferred method for the accurate calculation of CL and was useful despite liver failure and ascites. |
format | Online Article Text |
id | pubmed-3218286 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-32182862011-12-09 Validation of Tikhonov adaptively regularized gamma variate fitting with 24-h plasma clearance in cirrhotic patients with ascites Wesolowski, Carl Adam Ling, Lin Xirouchakis, Elias Burniston, Maria T. Puetter, Richard C. Babyn, Paul S. Giamalis, Ioannis G. Burroughs, Andrew K. Eur J Nucl Med Mol Imaging Original Article PURPOSE: The aim was to compare late-time extrapolation of plasma clearance (CL) from Tikhonov adaptively regularized gamma variate fitting (Tk-GV) and from mono-exponential (E1) fitting. METHODS: Ten (51)Cr-ethylenediaminetetraacetic acid bolus IV studies in adults—8 with ascites—assessed for liver transplantation, with 12–16 plasma samples drawn from 5-min to 24-h, were fit with Tk-GV and E1 models and CL results were compared using Passing-Bablok fitting. RESULTS: The 24-h CL(Tk-GV) values ranged from 11.4 to 79.7 ml/min. Linear regression of 4- versus 24-h CL(Tk-GV) yielded no significant departure from a slope of 1, whereas the 4- versus 24-h CL(E1) slope, 1.56, was significantly increased. For CL(Tk-GV-24-h) versus CL(E1-24-h), there was a biased slope and intercept (0.85, 5.97 ml/min). Moreover, the quality of fitting of 24-h data was significantly better for Tk-GV than for E1, as follows. For 10 logarithm of concentration curves, higher r values were obtained for each Tk-GV fit (median 0.998) than for its corresponding E1 fit (median 0.965), with p < 0.0001 (paired t-test of z-statistics from Fisher r-z transformations). The E1 fit quality degraded with increasing V/W [volume of distribution (l) per kg body weight, p = 0.003]. However, Tk-GV fit quality versus V/W was uncorrelated (p = 0.8). CONCLUSION: CL(E1) values were dependent on sample time and the quality of fit was poor and degraded with increasing ascites, consistent with current opinion that CL(E1) is contraindicated in ascitic patients. CL(Tk-GV) was relatively more accurate and the good quality of fit was unaffected by ascites. CL(Tk-GV) was the preferred method for the accurate calculation of CL and was useful despite liver failure and ascites. Springer-Verlag 2011-09-01 2011 /pmc/articles/PMC3218286/ /pubmed/21881927 http://dx.doi.org/10.1007/s00259-011-1887-9 Text en © The Author(s) 2011 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Original Article Wesolowski, Carl Adam Ling, Lin Xirouchakis, Elias Burniston, Maria T. Puetter, Richard C. Babyn, Paul S. Giamalis, Ioannis G. Burroughs, Andrew K. Validation of Tikhonov adaptively regularized gamma variate fitting with 24-h plasma clearance in cirrhotic patients with ascites |
title | Validation of Tikhonov adaptively regularized gamma variate fitting with 24-h plasma clearance in cirrhotic patients with ascites |
title_full | Validation of Tikhonov adaptively regularized gamma variate fitting with 24-h plasma clearance in cirrhotic patients with ascites |
title_fullStr | Validation of Tikhonov adaptively regularized gamma variate fitting with 24-h plasma clearance in cirrhotic patients with ascites |
title_full_unstemmed | Validation of Tikhonov adaptively regularized gamma variate fitting with 24-h plasma clearance in cirrhotic patients with ascites |
title_short | Validation of Tikhonov adaptively regularized gamma variate fitting with 24-h plasma clearance in cirrhotic patients with ascites |
title_sort | validation of tikhonov adaptively regularized gamma variate fitting with 24-h plasma clearance in cirrhotic patients with ascites |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3218286/ https://www.ncbi.nlm.nih.gov/pubmed/21881927 http://dx.doi.org/10.1007/s00259-011-1887-9 |
work_keys_str_mv | AT wesolowskicarladam validationoftikhonovadaptivelyregularizedgammavariatefittingwith24hplasmaclearanceincirrhoticpatientswithascites AT linglin validationoftikhonovadaptivelyregularizedgammavariatefittingwith24hplasmaclearanceincirrhoticpatientswithascites AT xirouchakiselias validationoftikhonovadaptivelyregularizedgammavariatefittingwith24hplasmaclearanceincirrhoticpatientswithascites AT burnistonmariat validationoftikhonovadaptivelyregularizedgammavariatefittingwith24hplasmaclearanceincirrhoticpatientswithascites AT puetterrichardc validationoftikhonovadaptivelyregularizedgammavariatefittingwith24hplasmaclearanceincirrhoticpatientswithascites AT babynpauls validationoftikhonovadaptivelyregularizedgammavariatefittingwith24hplasmaclearanceincirrhoticpatientswithascites AT giamalisioannisg validationoftikhonovadaptivelyregularizedgammavariatefittingwith24hplasmaclearanceincirrhoticpatientswithascites AT burroughsandrewk validationoftikhonovadaptivelyregularizedgammavariatefittingwith24hplasmaclearanceincirrhoticpatientswithascites |