Comparisons of different mean airway pressure settings during high-frequency oscillation in inflammatory response to oleic acid-induced lung injury in rabbits
PURPOSE: The present study was designed to examine effects of different mean airway pressure (MAP) settings during high-frequency oscillation (HFO) on oxygenation and inflammatory responses to acute lung injury (ALI) in rabbits. METHODS: Anesthetized rabbits were mechanically ventilated with a conve...
Autores principales: | Ono, Koichi, Koizumi, Tomonobu, Nakagawa, Rikimaru, Yoshikawa, Sumiko, Otagiri, Tetsutarou |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3218723/ https://www.ncbi.nlm.nih.gov/pubmed/22096349 |
Ejemplares similares
-
Continuous negative extrathoracic pressure combined with high-frequency oscillation improves oxygenation with less impact on blood pressure than high-frequency oscillation alone in a rabbit model of surfactant depletion
por: Naito, Sachie, et al.
Publicado: (2007) -
Exercise capacity in relation to autoantibodies in systemic sclerosis patients
por: Someya, Fujiko, et al.
Publicado: (2012) -
Transpulmonary pressure during high-frequency oscillation ventilation: Is it the culprit?
por: Cressoni, M., et al.
Publicado: (2016) -
Moderately high frequency ventilation with a conventional ventilator allows reduction of tidal volume without increasing mean airway pressure
por: Cordioli, Ricardo Luiz, et al.
Publicado: (2014) -
Association of central venous pressure with intra-abdominal pressure, mean airway pressure and hemodynamics: an observational study
por: Huber, W, et al.
Publicado: (2015)