Cargando…

Early non-invasive cardiac output monitoring in hemodynamically unstable intensive care patients: A multi-center randomized controlled trial

INTRODUCTION: Acute hemodynamic instability increases morbidity and mortality. We investigated whether early non-invasive cardiac output monitoring enhances hemodynamic stabilization and improves outcome. METHODS: A multicenter, randomized controlled trial was conducted in three European university...

Descripción completa

Detalles Bibliográficos
Autores principales: Takala, Jukka, Ruokonen, Esko, Tenhunen, Jyrki J, Parviainen, Ilkka, Jakob, Stephan M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3219022/
https://www.ncbi.nlm.nih.gov/pubmed/21676229
http://dx.doi.org/10.1186/cc10273
_version_ 1782216780972818432
author Takala, Jukka
Ruokonen, Esko
Tenhunen, Jyrki J
Parviainen, Ilkka
Jakob, Stephan M
author_facet Takala, Jukka
Ruokonen, Esko
Tenhunen, Jyrki J
Parviainen, Ilkka
Jakob, Stephan M
author_sort Takala, Jukka
collection PubMed
description INTRODUCTION: Acute hemodynamic instability increases morbidity and mortality. We investigated whether early non-invasive cardiac output monitoring enhances hemodynamic stabilization and improves outcome. METHODS: A multicenter, randomized controlled trial was conducted in three European university hospital intensive care units in 2006 and 2007. A total of 388 hemodynamically unstable patients identified during their first six hours in the intensive care unit (ICU) were randomized to receive either non-invasive cardiac output monitoring for 24 hrs (minimally invasive cardiac output/MICO group; n = 201) or usual care (control group; n = 187). The main outcome measure was the proportion of patients achieving hemodynamic stability within six hours of starting the study. RESULTS: The number of hemodynamic instability criteria at baseline (MICO group mean 2.0 (SD 1.0), control group 1.8 (1.0); P = .06) and severity of illness (SAPS II score; MICO group 48 (18), control group 48 (15); P = .86)) were similar. At 6 hrs, 45 patients (22%) in the MICO group and 52 patients (28%) in the control group were hemodynamically stable (mean difference 5%; 95% confidence interval of the difference -3 to 14%; P = .24). Hemodynamic support with fluids and vasoactive drugs, and pulmonary artery catheter use (MICO group: 19%, control group: 26%; P = .11) were similar in the two groups. The median length of ICU stay was 2.0 (interquartile range 1.2 to 4.6) days in the MICO group and 2.5 (1.1 to 5.0) days in the control group (P = .38). The hospital mortality was 26% in the MICO group and 21% in the control group (P = .34). CONCLUSIONS: Minimally-invasive cardiac output monitoring added to usual care does not facilitate early hemodynamic stabilization in the ICU, nor does it alter the hemodynamic support or outcome. Our results emphasize the need to evaluate technologies used to measure stroke volume and cardiac output--especially their impact on the process of care--before any large-scale outcome studies are attempted. TRIAL REGISTRATION: The study was registered at ClinicalTrials.gov (Clinical Trials identifier NCT00354211)
format Online
Article
Text
id pubmed-3219022
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-32190222011-11-17 Early non-invasive cardiac output monitoring in hemodynamically unstable intensive care patients: A multi-center randomized controlled trial Takala, Jukka Ruokonen, Esko Tenhunen, Jyrki J Parviainen, Ilkka Jakob, Stephan M Crit Care Research INTRODUCTION: Acute hemodynamic instability increases morbidity and mortality. We investigated whether early non-invasive cardiac output monitoring enhances hemodynamic stabilization and improves outcome. METHODS: A multicenter, randomized controlled trial was conducted in three European university hospital intensive care units in 2006 and 2007. A total of 388 hemodynamically unstable patients identified during their first six hours in the intensive care unit (ICU) were randomized to receive either non-invasive cardiac output monitoring for 24 hrs (minimally invasive cardiac output/MICO group; n = 201) or usual care (control group; n = 187). The main outcome measure was the proportion of patients achieving hemodynamic stability within six hours of starting the study. RESULTS: The number of hemodynamic instability criteria at baseline (MICO group mean 2.0 (SD 1.0), control group 1.8 (1.0); P = .06) and severity of illness (SAPS II score; MICO group 48 (18), control group 48 (15); P = .86)) were similar. At 6 hrs, 45 patients (22%) in the MICO group and 52 patients (28%) in the control group were hemodynamically stable (mean difference 5%; 95% confidence interval of the difference -3 to 14%; P = .24). Hemodynamic support with fluids and vasoactive drugs, and pulmonary artery catheter use (MICO group: 19%, control group: 26%; P = .11) were similar in the two groups. The median length of ICU stay was 2.0 (interquartile range 1.2 to 4.6) days in the MICO group and 2.5 (1.1 to 5.0) days in the control group (P = .38). The hospital mortality was 26% in the MICO group and 21% in the control group (P = .34). CONCLUSIONS: Minimally-invasive cardiac output monitoring added to usual care does not facilitate early hemodynamic stabilization in the ICU, nor does it alter the hemodynamic support or outcome. Our results emphasize the need to evaluate technologies used to measure stroke volume and cardiac output--especially their impact on the process of care--before any large-scale outcome studies are attempted. TRIAL REGISTRATION: The study was registered at ClinicalTrials.gov (Clinical Trials identifier NCT00354211) BioMed Central 2011 2011-06-15 /pmc/articles/PMC3219022/ /pubmed/21676229 http://dx.doi.org/10.1186/cc10273 Text en Copyright ©2011 Takala et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Takala, Jukka
Ruokonen, Esko
Tenhunen, Jyrki J
Parviainen, Ilkka
Jakob, Stephan M
Early non-invasive cardiac output monitoring in hemodynamically unstable intensive care patients: A multi-center randomized controlled trial
title Early non-invasive cardiac output monitoring in hemodynamically unstable intensive care patients: A multi-center randomized controlled trial
title_full Early non-invasive cardiac output monitoring in hemodynamically unstable intensive care patients: A multi-center randomized controlled trial
title_fullStr Early non-invasive cardiac output monitoring in hemodynamically unstable intensive care patients: A multi-center randomized controlled trial
title_full_unstemmed Early non-invasive cardiac output monitoring in hemodynamically unstable intensive care patients: A multi-center randomized controlled trial
title_short Early non-invasive cardiac output monitoring in hemodynamically unstable intensive care patients: A multi-center randomized controlled trial
title_sort early non-invasive cardiac output monitoring in hemodynamically unstable intensive care patients: a multi-center randomized controlled trial
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3219022/
https://www.ncbi.nlm.nih.gov/pubmed/21676229
http://dx.doi.org/10.1186/cc10273
work_keys_str_mv AT takalajukka earlynoninvasivecardiacoutputmonitoringinhemodynamicallyunstableintensivecarepatientsamulticenterrandomizedcontrolledtrial
AT ruokonenesko earlynoninvasivecardiacoutputmonitoringinhemodynamicallyunstableintensivecarepatientsamulticenterrandomizedcontrolledtrial
AT tenhunenjyrkij earlynoninvasivecardiacoutputmonitoringinhemodynamicallyunstableintensivecarepatientsamulticenterrandomizedcontrolledtrial
AT parviainenilkka earlynoninvasivecardiacoutputmonitoringinhemodynamicallyunstableintensivecarepatientsamulticenterrandomizedcontrolledtrial
AT jakobstephanm earlynoninvasivecardiacoutputmonitoringinhemodynamicallyunstableintensivecarepatientsamulticenterrandomizedcontrolledtrial