Cargando…
Comparison of the central venous pressure from internal jugular vein and the pressure measured from the peripherally inserted antecubital central catheter (PICCP) in liver transplantation recipients
BACKGROUND: Unlike its use during stable conditions, central venous pressure (CVP) monitoring from a peripherally inserted central venous catheter (PICC) has not often been used in surgeries with significant hemodynamic alterations. The aim of this study was to evaluate the feasibility of measuring...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Anesthesiologists
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3219772/ https://www.ncbi.nlm.nih.gov/pubmed/22110879 http://dx.doi.org/10.4097/kjae.2011.61.4.281 |
_version_ | 1782216894990778368 |
---|---|
author | Yun, Jung-Yeon Park, So-Hee Cho, Dae-Soon Jeung, Hae-Jeung Lee, Soon-Ae Seo, So Jin |
author_facet | Yun, Jung-Yeon Park, So-Hee Cho, Dae-Soon Jeung, Hae-Jeung Lee, Soon-Ae Seo, So Jin |
author_sort | Yun, Jung-Yeon |
collection | PubMed |
description | BACKGROUND: Unlike its use during stable conditions, central venous pressure (CVP) monitoring from a peripherally inserted central venous catheter (PICC) has not often been used in surgeries with significant hemodynamic alterations. The aim of this study was to evaluate the feasibility of measuring PICC pressure (PICCP) as an alternative to measuring centrally inserted central catheter pressure (CICCP) in adult liver transplantation (LT) patients. METHODS: We measured PICCP and CICCP simultaneously during each main surgical period in adult LT. Statistical analysis was performed using simple linear regression analysis to observe whether changes in PICCP paralleled by simultaneous changes in CICCP. Correlation analysis and Bland-Altman analysis were used to determine the degree of agreement between the two devices. Differences were considered statistically significant when P values were less than 0.05. RESULTS: A total of 1342 data pairs were collected from 35 patients. The PICCPs and CICCPs were highly correlated overall (r = 0.970, P < 0.001) as well as at each period measured. The differences among each period were not clinically significant (0.33 mmHg for pre-anhepatic, 0.32 mmHg for anhepatic, -0.15 mmHg for reperfusion, and -0.10 mmHg for neohepatic periods). The overall mean difference was 0.14 mmHg (95% confidence interval: 0.09-0.19) and PICCP tended to give a higher reading by between 0.09 and 0.19 mmHg overall. The limit of agreement was -1.74 to 2.02 overall. CONCLUSIONS: These findings suggest that PICCP can be a reasonable alternative to CICCP in situations of dynamic systemic compliance and preload, as well as under stable hemodynamic conditions. |
format | Online Article Text |
id | pubmed-3219772 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | The Korean Society of Anesthesiologists |
record_format | MEDLINE/PubMed |
spelling | pubmed-32197722011-11-22 Comparison of the central venous pressure from internal jugular vein and the pressure measured from the peripherally inserted antecubital central catheter (PICCP) in liver transplantation recipients Yun, Jung-Yeon Park, So-Hee Cho, Dae-Soon Jeung, Hae-Jeung Lee, Soon-Ae Seo, So Jin Korean J Anesthesiol Clinical Research Article BACKGROUND: Unlike its use during stable conditions, central venous pressure (CVP) monitoring from a peripherally inserted central venous catheter (PICC) has not often been used in surgeries with significant hemodynamic alterations. The aim of this study was to evaluate the feasibility of measuring PICC pressure (PICCP) as an alternative to measuring centrally inserted central catheter pressure (CICCP) in adult liver transplantation (LT) patients. METHODS: We measured PICCP and CICCP simultaneously during each main surgical period in adult LT. Statistical analysis was performed using simple linear regression analysis to observe whether changes in PICCP paralleled by simultaneous changes in CICCP. Correlation analysis and Bland-Altman analysis were used to determine the degree of agreement between the two devices. Differences were considered statistically significant when P values were less than 0.05. RESULTS: A total of 1342 data pairs were collected from 35 patients. The PICCPs and CICCPs were highly correlated overall (r = 0.970, P < 0.001) as well as at each period measured. The differences among each period were not clinically significant (0.33 mmHg for pre-anhepatic, 0.32 mmHg for anhepatic, -0.15 mmHg for reperfusion, and -0.10 mmHg for neohepatic periods). The overall mean difference was 0.14 mmHg (95% confidence interval: 0.09-0.19) and PICCP tended to give a higher reading by between 0.09 and 0.19 mmHg overall. The limit of agreement was -1.74 to 2.02 overall. CONCLUSIONS: These findings suggest that PICCP can be a reasonable alternative to CICCP in situations of dynamic systemic compliance and preload, as well as under stable hemodynamic conditions. The Korean Society of Anesthesiologists 2011-10 2011-10-22 /pmc/articles/PMC3219772/ /pubmed/22110879 http://dx.doi.org/10.4097/kjae.2011.61.4.281 Text en Copyright © the Korean Society of Anesthesiologists, 2011 http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Research Article Yun, Jung-Yeon Park, So-Hee Cho, Dae-Soon Jeung, Hae-Jeung Lee, Soon-Ae Seo, So Jin Comparison of the central venous pressure from internal jugular vein and the pressure measured from the peripherally inserted antecubital central catheter (PICCP) in liver transplantation recipients |
title | Comparison of the central venous pressure from internal jugular vein and the pressure measured from the peripherally inserted antecubital central catheter (PICCP) in liver transplantation recipients |
title_full | Comparison of the central venous pressure from internal jugular vein and the pressure measured from the peripherally inserted antecubital central catheter (PICCP) in liver transplantation recipients |
title_fullStr | Comparison of the central venous pressure from internal jugular vein and the pressure measured from the peripherally inserted antecubital central catheter (PICCP) in liver transplantation recipients |
title_full_unstemmed | Comparison of the central venous pressure from internal jugular vein and the pressure measured from the peripherally inserted antecubital central catheter (PICCP) in liver transplantation recipients |
title_short | Comparison of the central venous pressure from internal jugular vein and the pressure measured from the peripherally inserted antecubital central catheter (PICCP) in liver transplantation recipients |
title_sort | comparison of the central venous pressure from internal jugular vein and the pressure measured from the peripherally inserted antecubital central catheter (piccp) in liver transplantation recipients |
topic | Clinical Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3219772/ https://www.ncbi.nlm.nih.gov/pubmed/22110879 http://dx.doi.org/10.4097/kjae.2011.61.4.281 |
work_keys_str_mv | AT yunjungyeon comparisonofthecentralvenouspressurefrominternaljugularveinandthepressuremeasuredfromtheperipherallyinsertedantecubitalcentralcatheterpiccpinlivertransplantationrecipients AT parksohee comparisonofthecentralvenouspressurefrominternaljugularveinandthepressuremeasuredfromtheperipherallyinsertedantecubitalcentralcatheterpiccpinlivertransplantationrecipients AT chodaesoon comparisonofthecentralvenouspressurefrominternaljugularveinandthepressuremeasuredfromtheperipherallyinsertedantecubitalcentralcatheterpiccpinlivertransplantationrecipients AT jeunghaejeung comparisonofthecentralvenouspressurefrominternaljugularveinandthepressuremeasuredfromtheperipherallyinsertedantecubitalcentralcatheterpiccpinlivertransplantationrecipients AT leesoonae comparisonofthecentralvenouspressurefrominternaljugularveinandthepressuremeasuredfromtheperipherallyinsertedantecubitalcentralcatheterpiccpinlivertransplantationrecipients AT seosojin comparisonofthecentralvenouspressurefrominternaljugularveinandthepressuremeasuredfromtheperipherallyinsertedantecubitalcentralcatheterpiccpinlivertransplantationrecipients |