Pharmacokinetics and Pharmacodynamics of High-Dose Human Regular U-500 Insulin Versus Human Regular U-100 Insulin in Healthy Obese Subjects
OBJECTIVE: Human regular U-500 (U-500R) insulin (500 units/mL) is increasingly being used clinically, yet its pharmacokinetics (PK) and pharmacodynamics (PD) have not been well studied. Therefore, we compared PK and PD of clinically relevant doses of U-500R with the same doses of human regular U-100...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Diabetes Association
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3220843/ https://www.ncbi.nlm.nih.gov/pubmed/21994429 http://dx.doi.org/10.2337/dc11-0721 |
Sumario: | OBJECTIVE: Human regular U-500 (U-500R) insulin (500 units/mL) is increasingly being used clinically, yet its pharmacokinetics (PK) and pharmacodynamics (PD) have not been well studied. Therefore, we compared PK and PD of clinically relevant doses of U-500R with the same doses of human regular U-100 (U-100R) insulin (100 units/mL). RESEARCH DESIGN AND METHODS: This was a single-site, randomized, double-blind, crossover euglycemic clamp study. Single subcutaneous injections of 50- and 100-unit doses of U-500R and U-100R were administered to 24 healthy obese subjects. RESULTS: Both overall insulin exposure (area under the serum insulin concentration versus time curve from zero to return to baseline [AUC(0-)(t)(’)]) and overall effect (total glucose infused during a clamp) were similar between formulations at both 50- and 100-unit doses (90% [CI] of ratios contained within [0.80, 1.25]). However, peak concentration and effect were significantly lower for U-500R at both doses (P < 0.05). Both formulations produced relatively long durations of action (18.3 to 21.5 h). Time-to-peak concentration and time to maximum effect were significantly longer for U-500R than U-100R at the 100-unit dose (P < 0.05). Time variables reflective of duration of action (late tR(max50), tR(last)) were prolonged for U-500R versus U-100R at both doses (P < 0.05). CONCLUSIONS: Overall exposure to and action of U-500R insulin after subcutaneous injection were no different from those of U-100R insulin. For U-500R, peaks of concentration and action profiles were blunted and the effect after the peak was prolonged. These findings may help guide therapy with U-500R insulin for highly insulin-resistant patients with diabetes. |
---|