INTRODUCTION: Continuous cardiac output monitoring is used for early detection of hemodynamic instability and guidance of therapy in critically ill patients. Recently, the accuracy of pulse contour-derived cardiac output (PCCO) has been questioned in different clinical situations. In this study, we...

Descripción completa

Detalles Bibliográficos
Autores principales: Gruenewald, Matthias, Meybohm, Patrick, Renner, Jochen, Broch, Ole, Caliebe, Amke, Weiler, Norbert, Steinfath, Markus, Scholz, Jens, Bein, Berthold
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3222056/
https://www.ncbi.nlm.nih.gov/pubmed/21241481
http://dx.doi.org/10.1186/cc9967
_version_ 1782217165282213888
author Gruenewald, Matthias
Meybohm, Patrick
Renner, Jochen
Broch, Ole
Caliebe, Amke
Weiler, Norbert
Steinfath, Markus
Scholz, Jens
Bein, Berthold
author_facet Gruenewald, Matthias
Meybohm, Patrick
Renner, Jochen
Broch, Ole
Caliebe, Amke
Weiler, Norbert
Steinfath, Markus
Scholz, Jens
Bein, Berthold
author_sort Gruenewald, Matthias
collection PubMed
description INTRODUCTION: Continuous cardiac output monitoring is used for early detection of hemodynamic instability and guidance of therapy in critically ill patients. Recently, the accuracy of pulse contour-derived cardiac output (PCCO) has been questioned in different clinical situations. In this study, we examined agreement between PCCO and transcardiopulmonary thermodilution cardiac output (CO(TCP)) in critically ill patients, with special emphasis on norepinephrine (NE) administration and the time interval between calibrations. METHODS: This prospective, observational study was performed with a sample of 73 patients (mean age, 63 ± 13 years) requiring invasive hemodynamic monitoring on a non-cardiac surgery intensive care unit. PCCO was recorded immediately before calibration by CO(TCP). Bland-Altman analysis was performed on data subsets comparing agreement between PCCO and CO(TCP )according to NE dosage and the time interval between calibrations up to 24 hours. Further, central artery stiffness was calculated on the basis of the pulse pressure to stroke volume relationship. RESULTS: A total of 330 data pairs were analyzed. For all data pairs, the mean CO(TCP )(±SD) was 8.2 ± 2.0 L/min. PCCO had a mean bias of 0.16 L/min with limits of agreement of -2.81 to 3.15 L/min (percentage error, 38%) when compared to CO(TCP). Whereas the bias between PCCO and CO(TCP )was not significantly different between NE dosage categories or categories of time elapsed between calibrations, interchangeability (percentage error <30%) between methods was present only in the high NE dosage subgroup (≥0.1 μg/kg/min), as the percentage errors were 40%, 47% and 28% in the no NE, NE < 0.1 and NE ≥ 0.1 μg/kg/min subgroups, respectively. PCCO was not interchangeable with CO(TCP )in subgroups of different calibration intervals. The high NE dosage group showed significantly increased central artery stiffness. CONCLUSIONS: This study shows that NE dosage, but not the time interval between calibrations, has an impact on the agreement between PCCO and CO(TCP). Only in the measurements with high NE dosage (representing the minority of measurements) was PCCO interchangeable with CO(TCP).
format Online
Article
Text
id pubmed-3222056
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-32220562011-11-22 Effect of norepinephrine dosage and calibration frequency on accuracy of pulse contour-derived cardiac output Gruenewald, Matthias Meybohm, Patrick Renner, Jochen Broch, Ole Caliebe, Amke Weiler, Norbert Steinfath, Markus Scholz, Jens Bein, Berthold Crit Care Research INTRODUCTION: Continuous cardiac output monitoring is used for early detection of hemodynamic instability and guidance of therapy in critically ill patients. Recently, the accuracy of pulse contour-derived cardiac output (PCCO) has been questioned in different clinical situations. In this study, we examined agreement between PCCO and transcardiopulmonary thermodilution cardiac output (CO(TCP)) in critically ill patients, with special emphasis on norepinephrine (NE) administration and the time interval between calibrations. METHODS: This prospective, observational study was performed with a sample of 73 patients (mean age, 63 ± 13 years) requiring invasive hemodynamic monitoring on a non-cardiac surgery intensive care unit. PCCO was recorded immediately before calibration by CO(TCP). Bland-Altman analysis was performed on data subsets comparing agreement between PCCO and CO(TCP )according to NE dosage and the time interval between calibrations up to 24 hours. Further, central artery stiffness was calculated on the basis of the pulse pressure to stroke volume relationship. RESULTS: A total of 330 data pairs were analyzed. For all data pairs, the mean CO(TCP )(±SD) was 8.2 ± 2.0 L/min. PCCO had a mean bias of 0.16 L/min with limits of agreement of -2.81 to 3.15 L/min (percentage error, 38%) when compared to CO(TCP). Whereas the bias between PCCO and CO(TCP )was not significantly different between NE dosage categories or categories of time elapsed between calibrations, interchangeability (percentage error <30%) between methods was present only in the high NE dosage subgroup (≥0.1 μg/kg/min), as the percentage errors were 40%, 47% and 28% in the no NE, NE < 0.1 and NE ≥ 0.1 μg/kg/min subgroups, respectively. PCCO was not interchangeable with CO(TCP )in subgroups of different calibration intervals. The high NE dosage group showed significantly increased central artery stiffness. CONCLUSIONS: This study shows that NE dosage, but not the time interval between calibrations, has an impact on the agreement between PCCO and CO(TCP). Only in the measurements with high NE dosage (representing the minority of measurements) was PCCO interchangeable with CO(TCP). BioMed Central 2011 2011-01-17 /pmc/articles/PMC3222056/ /pubmed/21241481 http://dx.doi.org/10.1186/cc9967 Text en Copyright ©2011 Gruenewald et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Gruenewald, Matthias
Meybohm, Patrick
Renner, Jochen
Broch, Ole
Caliebe, Amke
Weiler, Norbert
Steinfath, Markus
Scholz, Jens
Bein, Berthold
Effect of norepinephrine dosage and calibration frequency on accuracy of pulse contour-derived cardiac output
title Effect of norepinephrine dosage and calibration frequency on accuracy of pulse contour-derived cardiac output
title_full Effect of norepinephrine dosage and calibration frequency on accuracy of pulse contour-derived cardiac output
title_fullStr Effect of norepinephrine dosage and calibration frequency on accuracy of pulse contour-derived cardiac output
title_full_unstemmed Effect of norepinephrine dosage and calibration frequency on accuracy of pulse contour-derived cardiac output
title_short Effect of norepinephrine dosage and calibration frequency on accuracy of pulse contour-derived cardiac output
title_sort effect of norepinephrine dosage and calibration frequency on accuracy of pulse contour-derived cardiac output
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3222056/
https://www.ncbi.nlm.nih.gov/pubmed/21241481
http://dx.doi.org/10.1186/cc9967
work_keys_str_mv AT gruenewaldmatthias effectofnorepinephrinedosageandcalibrationfrequencyonaccuracyofpulsecontourderivedcardiacoutput
AT meybohmpatrick effectofnorepinephrinedosageandcalibrationfrequencyonaccuracyofpulsecontourderivedcardiacoutput
AT rennerjochen effectofnorepinephrinedosageandcalibrationfrequencyonaccuracyofpulsecontourderivedcardiacoutput
AT brochole effectofnorepinephrinedosageandcalibrationfrequencyonaccuracyofpulsecontourderivedcardiacoutput
AT caliebeamke effectofnorepinephrinedosageandcalibrationfrequencyonaccuracyofpulsecontourderivedcardiacoutput
AT weilernorbert effectofnorepinephrinedosageandcalibrationfrequencyonaccuracyofpulsecontourderivedcardiacoutput
AT steinfathmarkus effectofnorepinephrinedosageandcalibrationfrequencyonaccuracyofpulsecontourderivedcardiacoutput
AT scholzjens effectofnorepinephrinedosageandcalibrationfrequencyonaccuracyofpulsecontourderivedcardiacoutput
AT beinberthold effectofnorepinephrinedosageandcalibrationfrequencyonaccuracyofpulsecontourderivedcardiacoutput