Cargando…
Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire
BACKGROUND: Promising results have been reported for a urine circulating cathodic antigen (CCA) test for the diagnosis of Schistosoma mansoni. We assessed the accuracy of a commercially available CCA cassette test (designated CCA-A) and an experimental formulation (CCA-B) for S. mansoni diagnosis. M...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3222626/ https://www.ncbi.nlm.nih.gov/pubmed/22132246 http://dx.doi.org/10.1371/journal.pntd.0001384 |
_version_ | 1782217207780999168 |
---|---|
author | Coulibaly, Jean T. Knopp, Stefanie N'Guessan, Nicaise A. Silué, Kigbafori D. Fürst, Thomas Lohourignon, Laurent K. Brou, Jean K. N'Gbesso, Yve K. Vounatsou, Penelope N'Goran, Eliézer K. Utzinger, Jürg |
author_facet | Coulibaly, Jean T. Knopp, Stefanie N'Guessan, Nicaise A. Silué, Kigbafori D. Fürst, Thomas Lohourignon, Laurent K. Brou, Jean K. N'Gbesso, Yve K. Vounatsou, Penelope N'Goran, Eliézer K. Utzinger, Jürg |
author_sort | Coulibaly, Jean T. |
collection | PubMed |
description | BACKGROUND: Promising results have been reported for a urine circulating cathodic antigen (CCA) test for the diagnosis of Schistosoma mansoni. We assessed the accuracy of a commercially available CCA cassette test (designated CCA-A) and an experimental formulation (CCA-B) for S. mansoni diagnosis. METHODOLOGY: We conducted a cross-sectional survey in three settings of Côte d'Ivoire: settings A and B are endemic for S. mansoni, whereas S. haematobium co-exists in setting C. Overall, 446 children, aged 8–12 years, submitted multiple stool and urine samples. For S. mansoni diagnosis, stool samples were examined with triplicate Kato-Katz, whereas urine samples were tested with CCA-A. The first stool and urine samples were additionally subjected to an ether-concentration technique and CCA-B, respectively. Urine samples were examined for S. haematobium using a filtration method, and for microhematuria using Hemastix dipsticks. PRINCIPAL FINDINGS: Considering nine Kato-Katz as diagnostic ‘gold’ standard, the prevalence of S. mansoni in setting A, B and C was 32.9%, 53.1% and 91.8%, respectively. The sensitivity of triplicate Kato-Katz from the first stool and a single CCA-A test was 47.9% and 56.3% (setting A), 73.9% and 69.6% (setting B), and 94.2% and 89.6% (setting C). The respective sensitivity of a single CCA-B was 10.4%, 29.9% and 75.0%. The ether-concentration technique showed a low sensitivity for S. mansoni diagnosis (8.3–41.0%). The specificity of CCA-A was moderate (76.9–84.2%); CCA-B was high (96.7–100%). The likelihood of a CCA-A color reaction increased with higher S. mansoni fecal egg counts (odds ratio: 1.07, p<0.001). A concurrent S. haematobium infection or the presence of microhematuria did not influence the CCA-A test results for S. mansoni diagnosis. CONCLUSION/SIGNIFICANCE: CCA-A showed similar sensitivity than triplicate Kato-Katz for S. mansoni diagnosis with no cross-reactivity to S. haematobium and microhematuria. The low sensitivity of CCA-B in our study area precludes its use for S. mansoni diagnosis. |
format | Online Article Text |
id | pubmed-3222626 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-32226262011-11-30 Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire Coulibaly, Jean T. Knopp, Stefanie N'Guessan, Nicaise A. Silué, Kigbafori D. Fürst, Thomas Lohourignon, Laurent K. Brou, Jean K. N'Gbesso, Yve K. Vounatsou, Penelope N'Goran, Eliézer K. Utzinger, Jürg PLoS Negl Trop Dis Research Article BACKGROUND: Promising results have been reported for a urine circulating cathodic antigen (CCA) test for the diagnosis of Schistosoma mansoni. We assessed the accuracy of a commercially available CCA cassette test (designated CCA-A) and an experimental formulation (CCA-B) for S. mansoni diagnosis. METHODOLOGY: We conducted a cross-sectional survey in three settings of Côte d'Ivoire: settings A and B are endemic for S. mansoni, whereas S. haematobium co-exists in setting C. Overall, 446 children, aged 8–12 years, submitted multiple stool and urine samples. For S. mansoni diagnosis, stool samples were examined with triplicate Kato-Katz, whereas urine samples were tested with CCA-A. The first stool and urine samples were additionally subjected to an ether-concentration technique and CCA-B, respectively. Urine samples were examined for S. haematobium using a filtration method, and for microhematuria using Hemastix dipsticks. PRINCIPAL FINDINGS: Considering nine Kato-Katz as diagnostic ‘gold’ standard, the prevalence of S. mansoni in setting A, B and C was 32.9%, 53.1% and 91.8%, respectively. The sensitivity of triplicate Kato-Katz from the first stool and a single CCA-A test was 47.9% and 56.3% (setting A), 73.9% and 69.6% (setting B), and 94.2% and 89.6% (setting C). The respective sensitivity of a single CCA-B was 10.4%, 29.9% and 75.0%. The ether-concentration technique showed a low sensitivity for S. mansoni diagnosis (8.3–41.0%). The specificity of CCA-A was moderate (76.9–84.2%); CCA-B was high (96.7–100%). The likelihood of a CCA-A color reaction increased with higher S. mansoni fecal egg counts (odds ratio: 1.07, p<0.001). A concurrent S. haematobium infection or the presence of microhematuria did not influence the CCA-A test results for S. mansoni diagnosis. CONCLUSION/SIGNIFICANCE: CCA-A showed similar sensitivity than triplicate Kato-Katz for S. mansoni diagnosis with no cross-reactivity to S. haematobium and microhematuria. The low sensitivity of CCA-B in our study area precludes its use for S. mansoni diagnosis. Public Library of Science 2011-11-22 /pmc/articles/PMC3222626/ /pubmed/22132246 http://dx.doi.org/10.1371/journal.pntd.0001384 Text en Coulibaly et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Coulibaly, Jean T. Knopp, Stefanie N'Guessan, Nicaise A. Silué, Kigbafori D. Fürst, Thomas Lohourignon, Laurent K. Brou, Jean K. N'Gbesso, Yve K. Vounatsou, Penelope N'Goran, Eliézer K. Utzinger, Jürg Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire |
title | Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire |
title_full | Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire |
title_fullStr | Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire |
title_full_unstemmed | Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire |
title_short | Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire |
title_sort | accuracy of urine circulating cathodic antigen (cca) test for schistosoma mansoni diagnosis in different settings of côte d'ivoire |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3222626/ https://www.ncbi.nlm.nih.gov/pubmed/22132246 http://dx.doi.org/10.1371/journal.pntd.0001384 |
work_keys_str_mv | AT coulibalyjeant accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire AT knoppstefanie accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire AT nguessannicaisea accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire AT siluekigbaforid accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire AT furstthomas accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire AT lohourignonlaurentk accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire AT broujeank accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire AT ngbessoyvek accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire AT vounatsoupenelope accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire AT ngoraneliezerk accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire AT utzingerjurg accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire |