Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire

BACKGROUND: Promising results have been reported for a urine circulating cathodic antigen (CCA) test for the diagnosis of Schistosoma mansoni. We assessed the accuracy of a commercially available CCA cassette test (designated CCA-A) and an experimental formulation (CCA-B) for S. mansoni diagnosis. M...

Descripción completa

Detalles Bibliográficos
Autores principales: Coulibaly, Jean T., Knopp, Stefanie, N'Guessan, Nicaise A., Silué, Kigbafori D., Fürst, Thomas, Lohourignon, Laurent K., Brou, Jean K., N'Gbesso, Yve K., Vounatsou, Penelope, N'Goran, Eliézer K., Utzinger, Jürg
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3222626/
https://www.ncbi.nlm.nih.gov/pubmed/22132246
http://dx.doi.org/10.1371/journal.pntd.0001384
_version_ 1782217207780999168
author Coulibaly, Jean T.
Knopp, Stefanie
N'Guessan, Nicaise A.
Silué, Kigbafori D.
Fürst, Thomas
Lohourignon, Laurent K.
Brou, Jean K.
N'Gbesso, Yve K.
Vounatsou, Penelope
N'Goran, Eliézer K.
Utzinger, Jürg
author_facet Coulibaly, Jean T.
Knopp, Stefanie
N'Guessan, Nicaise A.
Silué, Kigbafori D.
Fürst, Thomas
Lohourignon, Laurent K.
Brou, Jean K.
N'Gbesso, Yve K.
Vounatsou, Penelope
N'Goran, Eliézer K.
Utzinger, Jürg
author_sort Coulibaly, Jean T.
collection PubMed
description BACKGROUND: Promising results have been reported for a urine circulating cathodic antigen (CCA) test for the diagnosis of Schistosoma mansoni. We assessed the accuracy of a commercially available CCA cassette test (designated CCA-A) and an experimental formulation (CCA-B) for S. mansoni diagnosis. METHODOLOGY: We conducted a cross-sectional survey in three settings of Côte d'Ivoire: settings A and B are endemic for S. mansoni, whereas S. haematobium co-exists in setting C. Overall, 446 children, aged 8–12 years, submitted multiple stool and urine samples. For S. mansoni diagnosis, stool samples were examined with triplicate Kato-Katz, whereas urine samples were tested with CCA-A. The first stool and urine samples were additionally subjected to an ether-concentration technique and CCA-B, respectively. Urine samples were examined for S. haematobium using a filtration method, and for microhematuria using Hemastix dipsticks. PRINCIPAL FINDINGS: Considering nine Kato-Katz as diagnostic ‘gold’ standard, the prevalence of S. mansoni in setting A, B and C was 32.9%, 53.1% and 91.8%, respectively. The sensitivity of triplicate Kato-Katz from the first stool and a single CCA-A test was 47.9% and 56.3% (setting A), 73.9% and 69.6% (setting B), and 94.2% and 89.6% (setting C). The respective sensitivity of a single CCA-B was 10.4%, 29.9% and 75.0%. The ether-concentration technique showed a low sensitivity for S. mansoni diagnosis (8.3–41.0%). The specificity of CCA-A was moderate (76.9–84.2%); CCA-B was high (96.7–100%). The likelihood of a CCA-A color reaction increased with higher S. mansoni fecal egg counts (odds ratio: 1.07, p<0.001). A concurrent S. haematobium infection or the presence of microhematuria did not influence the CCA-A test results for S. mansoni diagnosis. CONCLUSION/SIGNIFICANCE: CCA-A showed similar sensitivity than triplicate Kato-Katz for S. mansoni diagnosis with no cross-reactivity to S. haematobium and microhematuria. The low sensitivity of CCA-B in our study area precludes its use for S. mansoni diagnosis.
format Online
Article
Text
id pubmed-3222626
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-32226262011-11-30 Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire Coulibaly, Jean T. Knopp, Stefanie N'Guessan, Nicaise A. Silué, Kigbafori D. Fürst, Thomas Lohourignon, Laurent K. Brou, Jean K. N'Gbesso, Yve K. Vounatsou, Penelope N'Goran, Eliézer K. Utzinger, Jürg PLoS Negl Trop Dis Research Article BACKGROUND: Promising results have been reported for a urine circulating cathodic antigen (CCA) test for the diagnosis of Schistosoma mansoni. We assessed the accuracy of a commercially available CCA cassette test (designated CCA-A) and an experimental formulation (CCA-B) for S. mansoni diagnosis. METHODOLOGY: We conducted a cross-sectional survey in three settings of Côte d'Ivoire: settings A and B are endemic for S. mansoni, whereas S. haematobium co-exists in setting C. Overall, 446 children, aged 8–12 years, submitted multiple stool and urine samples. For S. mansoni diagnosis, stool samples were examined with triplicate Kato-Katz, whereas urine samples were tested with CCA-A. The first stool and urine samples were additionally subjected to an ether-concentration technique and CCA-B, respectively. Urine samples were examined for S. haematobium using a filtration method, and for microhematuria using Hemastix dipsticks. PRINCIPAL FINDINGS: Considering nine Kato-Katz as diagnostic ‘gold’ standard, the prevalence of S. mansoni in setting A, B and C was 32.9%, 53.1% and 91.8%, respectively. The sensitivity of triplicate Kato-Katz from the first stool and a single CCA-A test was 47.9% and 56.3% (setting A), 73.9% and 69.6% (setting B), and 94.2% and 89.6% (setting C). The respective sensitivity of a single CCA-B was 10.4%, 29.9% and 75.0%. The ether-concentration technique showed a low sensitivity for S. mansoni diagnosis (8.3–41.0%). The specificity of CCA-A was moderate (76.9–84.2%); CCA-B was high (96.7–100%). The likelihood of a CCA-A color reaction increased with higher S. mansoni fecal egg counts (odds ratio: 1.07, p<0.001). A concurrent S. haematobium infection or the presence of microhematuria did not influence the CCA-A test results for S. mansoni diagnosis. CONCLUSION/SIGNIFICANCE: CCA-A showed similar sensitivity than triplicate Kato-Katz for S. mansoni diagnosis with no cross-reactivity to S. haematobium and microhematuria. The low sensitivity of CCA-B in our study area precludes its use for S. mansoni diagnosis. Public Library of Science 2011-11-22 /pmc/articles/PMC3222626/ /pubmed/22132246 http://dx.doi.org/10.1371/journal.pntd.0001384 Text en Coulibaly et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Coulibaly, Jean T.
Knopp, Stefanie
N'Guessan, Nicaise A.
Silué, Kigbafori D.
Fürst, Thomas
Lohourignon, Laurent K.
Brou, Jean K.
N'Gbesso, Yve K.
Vounatsou, Penelope
N'Goran, Eliézer K.
Utzinger, Jürg
Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire
title Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire
title_full Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire
title_fullStr Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire
title_full_unstemmed Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire
title_short Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire
title_sort accuracy of urine circulating cathodic antigen (cca) test for schistosoma mansoni diagnosis in different settings of côte d'ivoire
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3222626/
https://www.ncbi.nlm.nih.gov/pubmed/22132246
http://dx.doi.org/10.1371/journal.pntd.0001384
work_keys_str_mv AT coulibalyjeant accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire
AT knoppstefanie accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire
AT nguessannicaisea accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire
AT siluekigbaforid accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire
AT furstthomas accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire
AT lohourignonlaurentk accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire
AT broujeank accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire
AT ngbessoyvek accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire
AT vounatsoupenelope accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire
AT ngoraneliezerk accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire
AT utzingerjurg accuracyofurinecirculatingcathodicantigenccatestforschistosomamansonidiagnosisindifferentsettingsofcotedivoire