Cargando…

Diffusion tensor imaging tractography of the optic radiation for epilepsy surgical planning: A comparison of two methods

The optic radiation is a key white matter structure at risk during epilepsy surgery involving the temporal, parietal or occipital lobes. It shows considerable anatomical variability, cannot be delineated on clinical MRI sequences and damage may cause a disabling visual field deficit. Diffusion tenso...

Descripción completa

Detalles Bibliográficos
Autores principales: Winston, Gavin P., Mancini, Laura, Stretton, Jason, Ashmore, Jonathan, Symms, Mark R., Duncan, John S., Yousry, Tarek A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier Science Publishers 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3223565/
https://www.ncbi.nlm.nih.gov/pubmed/21885257
http://dx.doi.org/10.1016/j.eplepsyres.2011.07.019
_version_ 1782217300813807616
author Winston, Gavin P.
Mancini, Laura
Stretton, Jason
Ashmore, Jonathan
Symms, Mark R.
Duncan, John S.
Yousry, Tarek A.
author_facet Winston, Gavin P.
Mancini, Laura
Stretton, Jason
Ashmore, Jonathan
Symms, Mark R.
Duncan, John S.
Yousry, Tarek A.
author_sort Winston, Gavin P.
collection PubMed
description The optic radiation is a key white matter structure at risk during epilepsy surgery involving the temporal, parietal or occipital lobes. It shows considerable anatomical variability, cannot be delineated on clinical MRI sequences and damage may cause a disabling visual field deficit. Diffusion tensor imaging tractography allows non-invasive mapping of this pathway. Numerous methods have been published but direct comparison is difficult as patient, acquisition and analysis parameters differ. Two methods for delineating the optic radiation were applied to 6 healthy controls and 4 patients with epileptogenic lesions near the optic radiation. By comparing methods with the same datasets, many of the parameters could be controlled. The first method was previously developed to accurately identify Meyer's loop for planning anterior temporal lobe resection. The second aimed to address limitations of this method by using a more automated technique to reduce operator time and to depict the entire optic radiation. Whilst the core of the tract was common to both methods, there was significant variability between the methods. Method 1 gave a more consistent depiction of Meyer's loop with fewer spurious tracts. Method 2 gave a better depiction of the entire optic radiation, particularly in more posterior portions, but did not identify Meyer's loop in one patient. These results show that whilst tractography is a promising technique, there is significant variability depending on the method chosen even when the majority of parameters are fixed. Different methods may need to be chosen for surgical planning depending on the individual clinical situation.
format Online
Article
Text
id pubmed-3223565
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Elsevier Science Publishers
record_format MEDLINE/PubMed
spelling pubmed-32235652011-12-23 Diffusion tensor imaging tractography of the optic radiation for epilepsy surgical planning: A comparison of two methods Winston, Gavin P. Mancini, Laura Stretton, Jason Ashmore, Jonathan Symms, Mark R. Duncan, John S. Yousry, Tarek A. Epilepsy Res Article The optic radiation is a key white matter structure at risk during epilepsy surgery involving the temporal, parietal or occipital lobes. It shows considerable anatomical variability, cannot be delineated on clinical MRI sequences and damage may cause a disabling visual field deficit. Diffusion tensor imaging tractography allows non-invasive mapping of this pathway. Numerous methods have been published but direct comparison is difficult as patient, acquisition and analysis parameters differ. Two methods for delineating the optic radiation were applied to 6 healthy controls and 4 patients with epileptogenic lesions near the optic radiation. By comparing methods with the same datasets, many of the parameters could be controlled. The first method was previously developed to accurately identify Meyer's loop for planning anterior temporal lobe resection. The second aimed to address limitations of this method by using a more automated technique to reduce operator time and to depict the entire optic radiation. Whilst the core of the tract was common to both methods, there was significant variability between the methods. Method 1 gave a more consistent depiction of Meyer's loop with fewer spurious tracts. Method 2 gave a better depiction of the entire optic radiation, particularly in more posterior portions, but did not identify Meyer's loop in one patient. These results show that whilst tractography is a promising technique, there is significant variability depending on the method chosen even when the majority of parameters are fixed. Different methods may need to be chosen for surgical planning depending on the individual clinical situation. Elsevier Science Publishers 2011-11 /pmc/articles/PMC3223565/ /pubmed/21885257 http://dx.doi.org/10.1016/j.eplepsyres.2011.07.019 Text en © 2011 Elsevier B.V. https://creativecommons.org/licenses/by/4.0/ Open Access under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/) license
spellingShingle Article
Winston, Gavin P.
Mancini, Laura
Stretton, Jason
Ashmore, Jonathan
Symms, Mark R.
Duncan, John S.
Yousry, Tarek A.
Diffusion tensor imaging tractography of the optic radiation for epilepsy surgical planning: A comparison of two methods
title Diffusion tensor imaging tractography of the optic radiation for epilepsy surgical planning: A comparison of two methods
title_full Diffusion tensor imaging tractography of the optic radiation for epilepsy surgical planning: A comparison of two methods
title_fullStr Diffusion tensor imaging tractography of the optic radiation for epilepsy surgical planning: A comparison of two methods
title_full_unstemmed Diffusion tensor imaging tractography of the optic radiation for epilepsy surgical planning: A comparison of two methods
title_short Diffusion tensor imaging tractography of the optic radiation for epilepsy surgical planning: A comparison of two methods
title_sort diffusion tensor imaging tractography of the optic radiation for epilepsy surgical planning: a comparison of two methods
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3223565/
https://www.ncbi.nlm.nih.gov/pubmed/21885257
http://dx.doi.org/10.1016/j.eplepsyres.2011.07.019
work_keys_str_mv AT winstongavinp diffusiontensorimagingtractographyoftheopticradiationforepilepsysurgicalplanningacomparisonoftwomethods
AT mancinilaura diffusiontensorimagingtractographyoftheopticradiationforepilepsysurgicalplanningacomparisonoftwomethods
AT strettonjason diffusiontensorimagingtractographyoftheopticradiationforepilepsysurgicalplanningacomparisonoftwomethods
AT ashmorejonathan diffusiontensorimagingtractographyoftheopticradiationforepilepsysurgicalplanningacomparisonoftwomethods
AT symmsmarkr diffusiontensorimagingtractographyoftheopticradiationforepilepsysurgicalplanningacomparisonoftwomethods
AT duncanjohns diffusiontensorimagingtractographyoftheopticradiationforepilepsysurgicalplanningacomparisonoftwomethods
AT yousrytareka diffusiontensorimagingtractographyoftheopticradiationforepilepsysurgicalplanningacomparisonoftwomethods