Cargando…
Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling
BACKGROUND: Pedicle screws with PMMA cement augmentation have been shown to significantly improve the fixation strength in a severely osteoporotic spine. However, the efficacy of screw fixation for different cement augmentation techniques, namely solid screws with retrograde cement pre-filling versu...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3224375/ https://www.ncbi.nlm.nih.gov/pubmed/21284883 http://dx.doi.org/10.1186/1471-2474-12-33 |
_version_ | 1782217369472466944 |
---|---|
author | Chen, Lih-Huei Tai, Ching-Lung Lee, De-Mei Lai, Po-Liang Lee, Yen-Chen Niu, Chi-Chien Chen, Wen-Jer |
author_facet | Chen, Lih-Huei Tai, Ching-Lung Lee, De-Mei Lai, Po-Liang Lee, Yen-Chen Niu, Chi-Chien Chen, Wen-Jer |
author_sort | Chen, Lih-Huei |
collection | PubMed |
description | BACKGROUND: Pedicle screws with PMMA cement augmentation have been shown to significantly improve the fixation strength in a severely osteoporotic spine. However, the efficacy of screw fixation for different cement augmentation techniques, namely solid screws with retrograde cement pre-filling versus cannulated screws with cement injection through perforation, remains unknown. This study aimed to determine the difference in pullout strength between conical and cylindrical screws based on the aforementioned cement augmentation techniques. The potential loss of fixation upon partial screw removal after screw insertion was also examined. METHOD: The Taguchi method with an L(8 )array was employed to determine the significance of design factors. Conical and cylindrical pedicle screws with solid or cannulated designs were installed using two different screw augmentation techniques: solid screws with retrograde cement pre-filling and cannulated screws with cement injection through perforation. Uniform synthetic bones (test block) simulating severe osteoporosis were used to provide a platform for each screw design and cement augmentation technique. Pedicle screws at full insertion and after a 360-degree back-out from full insertion were then tested for axial pullout failure using a mechanical testing machine. RESULTS: The results revealed the following 1) Regardless of the screw outer geometry (conical or cylindrical), solid screws with retrograde cement pre-filling exhibited significantly higher pullout strength than did cannulated screws with cement injection through perforation (p = 0.0129 for conical screws; p = 0.005 for cylindrical screws). 2) For a given cement augmentation technique (screws without cement augmentation, cannulated screws with cement injection or solid screws with cement pre-filling), no significant difference in pullout strength was found between conical and cylindrical screws (p >0.05). 3) Cement infiltration into the open cell of the test block led to the formation of a cement/bone composite structure. Observations of the failed specimens indicated that failure occurred at the composite/bone interface, whereas the composite remained well bonded to the screws. This result implies that the screw/composite interfacial strength was much higher than the composite/bone interfacial strength. 4) The back-out of the screw by 360 degrees from full insertion did not decrease the pullout strength in any of the studied cases. 5) Generally, larger standard deviations were found for the screw back-out cases, implying that the results of full insertion cases are more repeatable than those of the back-out cases. CONCLUSIONS: Solid screws with retrograde cement pre-filling offer improved initial fixation strength when compared to that of cannulated screws with cement injection through perforation for both the conically and cylindrically shaped screw. Our results also suggest that the fixation screws can be backed out by 360 degrees for intra-operative adjustment without the loss of fixation strength. |
format | Online Article Text |
id | pubmed-3224375 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-32243752011-11-27 Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling Chen, Lih-Huei Tai, Ching-Lung Lee, De-Mei Lai, Po-Liang Lee, Yen-Chen Niu, Chi-Chien Chen, Wen-Jer BMC Musculoskelet Disord Research Article BACKGROUND: Pedicle screws with PMMA cement augmentation have been shown to significantly improve the fixation strength in a severely osteoporotic spine. However, the efficacy of screw fixation for different cement augmentation techniques, namely solid screws with retrograde cement pre-filling versus cannulated screws with cement injection through perforation, remains unknown. This study aimed to determine the difference in pullout strength between conical and cylindrical screws based on the aforementioned cement augmentation techniques. The potential loss of fixation upon partial screw removal after screw insertion was also examined. METHOD: The Taguchi method with an L(8 )array was employed to determine the significance of design factors. Conical and cylindrical pedicle screws with solid or cannulated designs were installed using two different screw augmentation techniques: solid screws with retrograde cement pre-filling and cannulated screws with cement injection through perforation. Uniform synthetic bones (test block) simulating severe osteoporosis were used to provide a platform for each screw design and cement augmentation technique. Pedicle screws at full insertion and after a 360-degree back-out from full insertion were then tested for axial pullout failure using a mechanical testing machine. RESULTS: The results revealed the following 1) Regardless of the screw outer geometry (conical or cylindrical), solid screws with retrograde cement pre-filling exhibited significantly higher pullout strength than did cannulated screws with cement injection through perforation (p = 0.0129 for conical screws; p = 0.005 for cylindrical screws). 2) For a given cement augmentation technique (screws without cement augmentation, cannulated screws with cement injection or solid screws with cement pre-filling), no significant difference in pullout strength was found between conical and cylindrical screws (p >0.05). 3) Cement infiltration into the open cell of the test block led to the formation of a cement/bone composite structure. Observations of the failed specimens indicated that failure occurred at the composite/bone interface, whereas the composite remained well bonded to the screws. This result implies that the screw/composite interfacial strength was much higher than the composite/bone interfacial strength. 4) The back-out of the screw by 360 degrees from full insertion did not decrease the pullout strength in any of the studied cases. 5) Generally, larger standard deviations were found for the screw back-out cases, implying that the results of full insertion cases are more repeatable than those of the back-out cases. CONCLUSIONS: Solid screws with retrograde cement pre-filling offer improved initial fixation strength when compared to that of cannulated screws with cement injection through perforation for both the conically and cylindrically shaped screw. Our results also suggest that the fixation screws can be backed out by 360 degrees for intra-operative adjustment without the loss of fixation strength. BioMed Central 2011-02-01 /pmc/articles/PMC3224375/ /pubmed/21284883 http://dx.doi.org/10.1186/1471-2474-12-33 Text en Copyright ©2011 Chen et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Chen, Lih-Huei Tai, Ching-Lung Lee, De-Mei Lai, Po-Liang Lee, Yen-Chen Niu, Chi-Chien Chen, Wen-Jer Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling |
title | Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling |
title_full | Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling |
title_fullStr | Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling |
title_full_unstemmed | Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling |
title_short | Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling |
title_sort | pullout strength of pedicle screws with cement augmentation in severe osteoporosis: a comparative study between cannulated screws with cement injection and solid screws with cement pre-filling |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3224375/ https://www.ncbi.nlm.nih.gov/pubmed/21284883 http://dx.doi.org/10.1186/1471-2474-12-33 |
work_keys_str_mv | AT chenlihhuei pulloutstrengthofpediclescrewswithcementaugmentationinsevereosteoporosisacomparativestudybetweencannulatedscrewswithcementinjectionandsolidscrewswithcementprefilling AT taichinglung pulloutstrengthofpediclescrewswithcementaugmentationinsevereosteoporosisacomparativestudybetweencannulatedscrewswithcementinjectionandsolidscrewswithcementprefilling AT leedemei pulloutstrengthofpediclescrewswithcementaugmentationinsevereosteoporosisacomparativestudybetweencannulatedscrewswithcementinjectionandsolidscrewswithcementprefilling AT laipoliang pulloutstrengthofpediclescrewswithcementaugmentationinsevereosteoporosisacomparativestudybetweencannulatedscrewswithcementinjectionandsolidscrewswithcementprefilling AT leeyenchen pulloutstrengthofpediclescrewswithcementaugmentationinsevereosteoporosisacomparativestudybetweencannulatedscrewswithcementinjectionandsolidscrewswithcementprefilling AT niuchichien pulloutstrengthofpediclescrewswithcementaugmentationinsevereosteoporosisacomparativestudybetweencannulatedscrewswithcementinjectionandsolidscrewswithcementprefilling AT chenwenjer pulloutstrengthofpediclescrewswithcementaugmentationinsevereosteoporosisacomparativestudybetweencannulatedscrewswithcementinjectionandsolidscrewswithcementprefilling |