Cargando…

Clinical detection and monitoring of acute pulmonary embolism: proof of concept of a computer-based method

BACKGROUND: The diagnostic ability of computer-based methods for cardiovascular system (CVS) monitoring offers significant clinical potential. This research tests the clinical applicability of a newly improved computer-based method for the proof of concept case of tracking changes in important hemod...

Descripción completa

Detalles Bibliográficos
Autores principales: Revie, James A, Stevenson, David J, Chase, J Geoffrey, Hann, Christopher E, Lambermont, Bernard C, Ghuysen, Alexandre, Kolh, Philippe, Morimont, Philippe, Shaw, Geoffrey M, Desaive, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3224493/
https://www.ncbi.nlm.nih.gov/pubmed/21906388
http://dx.doi.org/10.1186/2110-5820-1-33
_version_ 1782217396155580416
author Revie, James A
Stevenson, David J
Chase, J Geoffrey
Hann, Christopher E
Lambermont, Bernard C
Ghuysen, Alexandre
Kolh, Philippe
Morimont, Philippe
Shaw, Geoffrey M
Desaive, Thomas
author_facet Revie, James A
Stevenson, David J
Chase, J Geoffrey
Hann, Christopher E
Lambermont, Bernard C
Ghuysen, Alexandre
Kolh, Philippe
Morimont, Philippe
Shaw, Geoffrey M
Desaive, Thomas
author_sort Revie, James A
collection PubMed
description BACKGROUND: The diagnostic ability of computer-based methods for cardiovascular system (CVS) monitoring offers significant clinical potential. This research tests the clinical applicability of a newly improved computer-based method for the proof of concept case of tracking changes in important hemodynamic indices due to the influence acute pulmonary embolism (APE). METHODS: Hemodynamic measurements from a porcine model of APE were used to validate the method. Of these measurements, only those that are clinically available or inferable were used in to identify pig-specific computer models of the CVS, including the aortic and pulmonary artery pressure, stroke volume, heart rate, global end diastolic volume, and mitral and tricuspid valve closure times. Changes in the computer-derived parameters were analyzed and compared with experimental metrics and clinical indices to assess the clinical applicability of the technique and its ability to track the disease state. RESULTS: The subject-specific computer models accurately captured the increase in pulmonary resistance (R(pul)), the main cardiovascular consequence of APE, in all five pigs trials, which related well (R(2 )= 0.81) with the experimentally derived pulmonary vascular resistance. An increase in right ventricular contractility was identified, as expected, consistent with known reflex responses to APE. Furthermore, the modeled right ventricular expansion index (the ratio of right to left ventricular end diastolic volumes) closely followed the trends seen in the measured data (R(2 )= 0.92) used for validation, with sharp increases seen in the metric for the two pigs in a near-death state. These results show that the pig-specific models are capable of tracking disease-dependent changes in pulmonary resistance (afterload), right ventricular contractility (inotropy), and ventricular loading (preload) during induced APE. Continuous, accurate estimation of these fundamental metrics of cardiovascular status can help to assist clinicians with diagnosis, monitoring, and therapy-based decisions in an intensive care environment. Furthermore, because the method only uses measurements already available in the ICU, it can be implemented with no added risk to the patient and little extra cost. CONCLUSIONS: This computer-based monitoring method shows potential for real-time, continuous diagnosis and monitoring of acute CVS dysfunction in critically ill patients.
format Online
Article
Text
id pubmed-3224493
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Springer
record_format MEDLINE/PubMed
spelling pubmed-32244932011-12-16 Clinical detection and monitoring of acute pulmonary embolism: proof of concept of a computer-based method Revie, James A Stevenson, David J Chase, J Geoffrey Hann, Christopher E Lambermont, Bernard C Ghuysen, Alexandre Kolh, Philippe Morimont, Philippe Shaw, Geoffrey M Desaive, Thomas Ann Intensive Care Research BACKGROUND: The diagnostic ability of computer-based methods for cardiovascular system (CVS) monitoring offers significant clinical potential. This research tests the clinical applicability of a newly improved computer-based method for the proof of concept case of tracking changes in important hemodynamic indices due to the influence acute pulmonary embolism (APE). METHODS: Hemodynamic measurements from a porcine model of APE were used to validate the method. Of these measurements, only those that are clinically available or inferable were used in to identify pig-specific computer models of the CVS, including the aortic and pulmonary artery pressure, stroke volume, heart rate, global end diastolic volume, and mitral and tricuspid valve closure times. Changes in the computer-derived parameters were analyzed and compared with experimental metrics and clinical indices to assess the clinical applicability of the technique and its ability to track the disease state. RESULTS: The subject-specific computer models accurately captured the increase in pulmonary resistance (R(pul)), the main cardiovascular consequence of APE, in all five pigs trials, which related well (R(2 )= 0.81) with the experimentally derived pulmonary vascular resistance. An increase in right ventricular contractility was identified, as expected, consistent with known reflex responses to APE. Furthermore, the modeled right ventricular expansion index (the ratio of right to left ventricular end diastolic volumes) closely followed the trends seen in the measured data (R(2 )= 0.92) used for validation, with sharp increases seen in the metric for the two pigs in a near-death state. These results show that the pig-specific models are capable of tracking disease-dependent changes in pulmonary resistance (afterload), right ventricular contractility (inotropy), and ventricular loading (preload) during induced APE. Continuous, accurate estimation of these fundamental metrics of cardiovascular status can help to assist clinicians with diagnosis, monitoring, and therapy-based decisions in an intensive care environment. Furthermore, because the method only uses measurements already available in the ICU, it can be implemented with no added risk to the patient and little extra cost. CONCLUSIONS: This computer-based monitoring method shows potential for real-time, continuous diagnosis and monitoring of acute CVS dysfunction in critically ill patients. Springer 2011-08-11 /pmc/articles/PMC3224493/ /pubmed/21906388 http://dx.doi.org/10.1186/2110-5820-1-33 Text en Copyright ©2011 Revie et al; licensee Springer. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Revie, James A
Stevenson, David J
Chase, J Geoffrey
Hann, Christopher E
Lambermont, Bernard C
Ghuysen, Alexandre
Kolh, Philippe
Morimont, Philippe
Shaw, Geoffrey M
Desaive, Thomas
Clinical detection and monitoring of acute pulmonary embolism: proof of concept of a computer-based method
title Clinical detection and monitoring of acute pulmonary embolism: proof of concept of a computer-based method
title_full Clinical detection and monitoring of acute pulmonary embolism: proof of concept of a computer-based method
title_fullStr Clinical detection and monitoring of acute pulmonary embolism: proof of concept of a computer-based method
title_full_unstemmed Clinical detection and monitoring of acute pulmonary embolism: proof of concept of a computer-based method
title_short Clinical detection and monitoring of acute pulmonary embolism: proof of concept of a computer-based method
title_sort clinical detection and monitoring of acute pulmonary embolism: proof of concept of a computer-based method
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3224493/
https://www.ncbi.nlm.nih.gov/pubmed/21906388
http://dx.doi.org/10.1186/2110-5820-1-33
work_keys_str_mv AT reviejamesa clinicaldetectionandmonitoringofacutepulmonaryembolismproofofconceptofacomputerbasedmethod
AT stevensondavidj clinicaldetectionandmonitoringofacutepulmonaryembolismproofofconceptofacomputerbasedmethod
AT chasejgeoffrey clinicaldetectionandmonitoringofacutepulmonaryembolismproofofconceptofacomputerbasedmethod
AT hannchristophere clinicaldetectionandmonitoringofacutepulmonaryembolismproofofconceptofacomputerbasedmethod
AT lambermontbernardc clinicaldetectionandmonitoringofacutepulmonaryembolismproofofconceptofacomputerbasedmethod
AT ghuysenalexandre clinicaldetectionandmonitoringofacutepulmonaryembolismproofofconceptofacomputerbasedmethod
AT kolhphilippe clinicaldetectionandmonitoringofacutepulmonaryembolismproofofconceptofacomputerbasedmethod
AT morimontphilippe clinicaldetectionandmonitoringofacutepulmonaryembolismproofofconceptofacomputerbasedmethod
AT shawgeoffreym clinicaldetectionandmonitoringofacutepulmonaryembolismproofofconceptofacomputerbasedmethod
AT desaivethomas clinicaldetectionandmonitoringofacutepulmonaryembolismproofofconceptofacomputerbasedmethod