Laboratory evaluation on the sensitivity and specificity of a novel and rapid detection method for malaria diagnosis based on magneto-optical technology (MOT)
BACKGROUND: This study describes the laboratory evaluation of a novel diagnostic platform for malaria. The Magneto Optical Test (MOT) is based on the bio-physical detection of haemozoin in clinical samples. Having an assay time of around one minute, it offers the potential of high throughput screeni...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3224991/ https://www.ncbi.nlm.nih.gov/pubmed/20642834 http://dx.doi.org/10.1186/1475-2875-9-207 |
_version_ | 1782217471644663808 |
---|---|
author | Mens, Petra F Matelon, Raphael J Nour, Bakri YM Newman, Dave M Schallig, Henk DFH |
author_facet | Mens, Petra F Matelon, Raphael J Nour, Bakri YM Newman, Dave M Schallig, Henk DFH |
author_sort | Mens, Petra F |
collection | PubMed |
description | BACKGROUND: This study describes the laboratory evaluation of a novel diagnostic platform for malaria. The Magneto Optical Test (MOT) is based on the bio-physical detection of haemozoin in clinical samples. Having an assay time of around one minute, it offers the potential of high throughput screening. METHODS: Blood samples of confirmed malaria patients from different regions of Africa, patients with other diseases and healthy non-endemic controls were used in the present study. The samples were analysed with two reference tests, i.e. an histidine rich protein-2 based rapid diagnostic test (RDT) and a conventional Pan-Plasmodium PCR, and the MOT as index test. Data were entered in 2 × 2 tables and analysed for sensitivity and specificity. The agreement between microscopy, RDT and PCR and the MOT assay was determined by calculating Kappa values with a 95% confidence interval. RESULTS: The observed sensitivity/specificity of the MOT test in comparison with clinical description, RDT or PCR ranged from 77.2 - 78.8% (sensitivity) and from 72.5 - 74.6% (specificity). In general, the agreement between MOT and the other assays is around 0.5 indicating a moderate agreement between the reference and the index test. However, when RDT and PCR are compared to each other, an almost perfect agreement can be observed (k = 0.97) with a sensitivity and specificity of >95%. CONCLUSIONS: Although MOT sensitivity and specificity are currently not yet at a competing level compared to other diagnostic test, such as PCR and RDTs, it has a potential to rapidly screen patients for malaria in endemic as well as non-endemic countries. |
format | Online Article Text |
id | pubmed-3224991 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-32249912011-11-30 Laboratory evaluation on the sensitivity and specificity of a novel and rapid detection method for malaria diagnosis based on magneto-optical technology (MOT) Mens, Petra F Matelon, Raphael J Nour, Bakri YM Newman, Dave M Schallig, Henk DFH Malar J Research BACKGROUND: This study describes the laboratory evaluation of a novel diagnostic platform for malaria. The Magneto Optical Test (MOT) is based on the bio-physical detection of haemozoin in clinical samples. Having an assay time of around one minute, it offers the potential of high throughput screening. METHODS: Blood samples of confirmed malaria patients from different regions of Africa, patients with other diseases and healthy non-endemic controls were used in the present study. The samples were analysed with two reference tests, i.e. an histidine rich protein-2 based rapid diagnostic test (RDT) and a conventional Pan-Plasmodium PCR, and the MOT as index test. Data were entered in 2 × 2 tables and analysed for sensitivity and specificity. The agreement between microscopy, RDT and PCR and the MOT assay was determined by calculating Kappa values with a 95% confidence interval. RESULTS: The observed sensitivity/specificity of the MOT test in comparison with clinical description, RDT or PCR ranged from 77.2 - 78.8% (sensitivity) and from 72.5 - 74.6% (specificity). In general, the agreement between MOT and the other assays is around 0.5 indicating a moderate agreement between the reference and the index test. However, when RDT and PCR are compared to each other, an almost perfect agreement can be observed (k = 0.97) with a sensitivity and specificity of >95%. CONCLUSIONS: Although MOT sensitivity and specificity are currently not yet at a competing level compared to other diagnostic test, such as PCR and RDTs, it has a potential to rapidly screen patients for malaria in endemic as well as non-endemic countries. BioMed Central 2010-07-19 /pmc/articles/PMC3224991/ /pubmed/20642834 http://dx.doi.org/10.1186/1475-2875-9-207 Text en Copyright ©2010 Mens et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Mens, Petra F Matelon, Raphael J Nour, Bakri YM Newman, Dave M Schallig, Henk DFH Laboratory evaluation on the sensitivity and specificity of a novel and rapid detection method for malaria diagnosis based on magneto-optical technology (MOT) |
title | Laboratory evaluation on the sensitivity and specificity of a novel and rapid detection method for malaria diagnosis based on magneto-optical technology (MOT) |
title_full | Laboratory evaluation on the sensitivity and specificity of a novel and rapid detection method for malaria diagnosis based on magneto-optical technology (MOT) |
title_fullStr | Laboratory evaluation on the sensitivity and specificity of a novel and rapid detection method for malaria diagnosis based on magneto-optical technology (MOT) |
title_full_unstemmed | Laboratory evaluation on the sensitivity and specificity of a novel and rapid detection method for malaria diagnosis based on magneto-optical technology (MOT) |
title_short | Laboratory evaluation on the sensitivity and specificity of a novel and rapid detection method for malaria diagnosis based on magneto-optical technology (MOT) |
title_sort | laboratory evaluation on the sensitivity and specificity of a novel and rapid detection method for malaria diagnosis based on magneto-optical technology (mot) |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3224991/ https://www.ncbi.nlm.nih.gov/pubmed/20642834 http://dx.doi.org/10.1186/1475-2875-9-207 |
work_keys_str_mv | AT menspetraf laboratoryevaluationonthesensitivityandspecificityofanovelandrapiddetectionmethodformalariadiagnosisbasedonmagnetoopticaltechnologymot AT matelonraphaelj laboratoryevaluationonthesensitivityandspecificityofanovelandrapiddetectionmethodformalariadiagnosisbasedonmagnetoopticaltechnologymot AT nourbakriym laboratoryevaluationonthesensitivityandspecificityofanovelandrapiddetectionmethodformalariadiagnosisbasedonmagnetoopticaltechnologymot AT newmandavem laboratoryevaluationonthesensitivityandspecificityofanovelandrapiddetectionmethodformalariadiagnosisbasedonmagnetoopticaltechnologymot AT schallighenkdfh laboratoryevaluationonthesensitivityandspecificityofanovelandrapiddetectionmethodformalariadiagnosisbasedonmagnetoopticaltechnologymot |