Flow Changes after Endovascular Treatment of a Wide-Neck Anterior Communicating Artery Aneurysm by using X-configured Kissing Stents (Cross-Kissing Stents) Technique

Endovascular treatment for a wide-neck anterior communicating artery (AcomA) aneurysm remains technically challenging. Stent-assisted embolization has been proposed as an alternative of treatment of complex aneurysms. The X-configuration double-stent-assisted technique was used to achieve successful...

Descripción completa

Detalles Bibliográficos
Autores principales: Zeleňák, Kamil, Zeleňáková, Jana, DeRiggo, Július, Kurča, Egon, Boudný, Jaroslav, Poláček, Hubert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer-Verlag 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3228955/
https://www.ncbi.nlm.nih.gov/pubmed/21452072
http://dx.doi.org/10.1007/s00270-011-0153-7
_version_ 1782217891321479168
author Zeleňák, Kamil
Zeleňáková, Jana
DeRiggo, Július
Kurča, Egon
Boudný, Jaroslav
Poláček, Hubert
author_facet Zeleňák, Kamil
Zeleňáková, Jana
DeRiggo, Július
Kurča, Egon
Boudný, Jaroslav
Poláček, Hubert
author_sort Zeleňák, Kamil
collection PubMed
description Endovascular treatment for a wide-neck anterior communicating artery (AcomA) aneurysm remains technically challenging. Stent-assisted embolization has been proposed as an alternative of treatment of complex aneurysms. The X-configuration double-stent-assisted technique was used to achieve successful coiling of wide-neck AcomA aneurysm. Implanted stent can alter intra-arterial flow. Follow-up angiograms 4 months later showed flow changes due to used X-technique of stents implantation and filling of the anterior cerebral artery from the opposite internal carotid artery.
format Online
Article
Text
id pubmed-3228955
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-32289552011-12-27 Flow Changes after Endovascular Treatment of a Wide-Neck Anterior Communicating Artery Aneurysm by using X-configured Kissing Stents (Cross-Kissing Stents) Technique Zeleňák, Kamil Zeleňáková, Jana DeRiggo, Július Kurča, Egon Boudný, Jaroslav Poláček, Hubert Cardiovasc Intervent Radiol Case Report Endovascular treatment for a wide-neck anterior communicating artery (AcomA) aneurysm remains technically challenging. Stent-assisted embolization has been proposed as an alternative of treatment of complex aneurysms. The X-configuration double-stent-assisted technique was used to achieve successful coiling of wide-neck AcomA aneurysm. Implanted stent can alter intra-arterial flow. Follow-up angiograms 4 months later showed flow changes due to used X-technique of stents implantation and filling of the anterior cerebral artery from the opposite internal carotid artery. Springer-Verlag 2011-03-31 2011 /pmc/articles/PMC3228955/ /pubmed/21452072 http://dx.doi.org/10.1007/s00270-011-0153-7 Text en © The Author(s) 2011 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Case Report
Zeleňák, Kamil
Zeleňáková, Jana
DeRiggo, Július
Kurča, Egon
Boudný, Jaroslav
Poláček, Hubert
Flow Changes after Endovascular Treatment of a Wide-Neck Anterior Communicating Artery Aneurysm by using X-configured Kissing Stents (Cross-Kissing Stents) Technique
title Flow Changes after Endovascular Treatment of a Wide-Neck Anterior Communicating Artery Aneurysm by using X-configured Kissing Stents (Cross-Kissing Stents) Technique
title_full Flow Changes after Endovascular Treatment of a Wide-Neck Anterior Communicating Artery Aneurysm by using X-configured Kissing Stents (Cross-Kissing Stents) Technique
title_fullStr Flow Changes after Endovascular Treatment of a Wide-Neck Anterior Communicating Artery Aneurysm by using X-configured Kissing Stents (Cross-Kissing Stents) Technique
title_full_unstemmed Flow Changes after Endovascular Treatment of a Wide-Neck Anterior Communicating Artery Aneurysm by using X-configured Kissing Stents (Cross-Kissing Stents) Technique
title_short Flow Changes after Endovascular Treatment of a Wide-Neck Anterior Communicating Artery Aneurysm by using X-configured Kissing Stents (Cross-Kissing Stents) Technique
title_sort flow changes after endovascular treatment of a wide-neck anterior communicating artery aneurysm by using x-configured kissing stents (cross-kissing stents) technique
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3228955/
https://www.ncbi.nlm.nih.gov/pubmed/21452072
http://dx.doi.org/10.1007/s00270-011-0153-7
work_keys_str_mv AT zelenakkamil flowchangesafterendovasculartreatmentofawideneckanteriorcommunicatingarteryaneurysmbyusingxconfiguredkissingstentscrosskissingstentstechnique
AT zelenakovajana flowchangesafterendovasculartreatmentofawideneckanteriorcommunicatingarteryaneurysmbyusingxconfiguredkissingstentscrosskissingstentstechnique
AT deriggojulius flowchangesafterendovasculartreatmentofawideneckanteriorcommunicatingarteryaneurysmbyusingxconfiguredkissingstentscrosskissingstentstechnique
AT kurcaegon flowchangesafterendovasculartreatmentofawideneckanteriorcommunicatingarteryaneurysmbyusingxconfiguredkissingstentscrosskissingstentstechnique
AT boudnyjaroslav flowchangesafterendovasculartreatmentofawideneckanteriorcommunicatingarteryaneurysmbyusingxconfiguredkissingstentscrosskissingstentstechnique
AT polacekhubert flowchangesafterendovasculartreatmentofawideneckanteriorcommunicatingarteryaneurysmbyusingxconfiguredkissingstentscrosskissingstentstechnique