Cargando…
Performance of the CareStart™ G6PD Deficiency Screening Test, a Point-of-Care Diagnostic for Primaquine Therapy Screening
Development of reliable, easy-to-use, rapid diagnostic tests (RDTs) to detect glucose-6-phosphate dehydrogenase (G6PD) deficiency at point of care is essential to deploying primaquine therapies as part of malaria elimination strategies. We assessed a kit under research and development called CareSta...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3229584/ https://www.ncbi.nlm.nih.gov/pubmed/22164279 http://dx.doi.org/10.1371/journal.pone.0028357 |
_version_ | 1782217970265620480 |
---|---|
author | Kim, Saorin Nguon, Chea Guillard, Bertrand Duong, Socheat Chy, Sophy Sum, Sarorn Nhem, Sina Bouchier, Christiane Tichit, Magali Christophel, Eva Taylor, Walter R. J. Baird, John Kevin Menard, Didier |
author_facet | Kim, Saorin Nguon, Chea Guillard, Bertrand Duong, Socheat Chy, Sophy Sum, Sarorn Nhem, Sina Bouchier, Christiane Tichit, Magali Christophel, Eva Taylor, Walter R. J. Baird, John Kevin Menard, Didier |
author_sort | Kim, Saorin |
collection | PubMed |
description | Development of reliable, easy-to-use, rapid diagnostic tests (RDTs) to detect glucose-6-phosphate dehydrogenase (G6PD) deficiency at point of care is essential to deploying primaquine therapies as part of malaria elimination strategies. We assessed a kit under research and development called CareStart™ G6PD deficiency screening test (Access Bio, New Jersey, USA) by comparing its performance to quantitative G6PD enzyme activity using a standardized spectrophotometric method (‘gold standard’). Blood samples (n = 903) were collected from Cambodian adults living in Pailin province, western Cambodia. G6PD enzyme activities ranged from 0 to 20.5 U/g Hb (median 12.0 U/g Hg). Based on a normal haemoglobin concentration and wild-type G6PD gene, the normal values of G6PD enzymatic activity for this population was 3.6 to 20.5 U/g Hg (95(th) percentiles from 5.5 to 17.2 U/g Hg). Ninety-seven subjects (10.7%) had <3.6 U/g Hg and were classified as G6PD deficient. Prevalence of deficiency was 15.0% (64/425) among men and 6.9% (33/478) among women. Genotype was analyzed in 66 G6PD-deficient subjects and 63 of these exhibited findings consistent with Viangchang genotype. The sensitivity and specificity of the CareStart™ G6PD deficiency screening test was 0.68 and 1.0, respectively. Its detection threshold was <2.7 U/g Hg, well within the range of moderate and severe enzyme deficiencies. Thirteen subjects (1.4%, 12 males and 1 female) with G6PD enzyme activities <2 U/g Hg were falsely classified as “normal” by RDT. This experimental RDT test here evaluated outside of the laboratory for the first time shows real promise, but safe application of it will require lower rates of falsely “normal” results. |
format | Online Article Text |
id | pubmed-3229584 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-32295842011-12-07 Performance of the CareStart™ G6PD Deficiency Screening Test, a Point-of-Care Diagnostic for Primaquine Therapy Screening Kim, Saorin Nguon, Chea Guillard, Bertrand Duong, Socheat Chy, Sophy Sum, Sarorn Nhem, Sina Bouchier, Christiane Tichit, Magali Christophel, Eva Taylor, Walter R. J. Baird, John Kevin Menard, Didier PLoS One Research Article Development of reliable, easy-to-use, rapid diagnostic tests (RDTs) to detect glucose-6-phosphate dehydrogenase (G6PD) deficiency at point of care is essential to deploying primaquine therapies as part of malaria elimination strategies. We assessed a kit under research and development called CareStart™ G6PD deficiency screening test (Access Bio, New Jersey, USA) by comparing its performance to quantitative G6PD enzyme activity using a standardized spectrophotometric method (‘gold standard’). Blood samples (n = 903) were collected from Cambodian adults living in Pailin province, western Cambodia. G6PD enzyme activities ranged from 0 to 20.5 U/g Hb (median 12.0 U/g Hg). Based on a normal haemoglobin concentration and wild-type G6PD gene, the normal values of G6PD enzymatic activity for this population was 3.6 to 20.5 U/g Hg (95(th) percentiles from 5.5 to 17.2 U/g Hg). Ninety-seven subjects (10.7%) had <3.6 U/g Hg and were classified as G6PD deficient. Prevalence of deficiency was 15.0% (64/425) among men and 6.9% (33/478) among women. Genotype was analyzed in 66 G6PD-deficient subjects and 63 of these exhibited findings consistent with Viangchang genotype. The sensitivity and specificity of the CareStart™ G6PD deficiency screening test was 0.68 and 1.0, respectively. Its detection threshold was <2.7 U/g Hg, well within the range of moderate and severe enzyme deficiencies. Thirteen subjects (1.4%, 12 males and 1 female) with G6PD enzyme activities <2 U/g Hg were falsely classified as “normal” by RDT. This experimental RDT test here evaluated outside of the laboratory for the first time shows real promise, but safe application of it will require lower rates of falsely “normal” results. Public Library of Science 2011-12-02 /pmc/articles/PMC3229584/ /pubmed/22164279 http://dx.doi.org/10.1371/journal.pone.0028357 Text en Kim et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Kim, Saorin Nguon, Chea Guillard, Bertrand Duong, Socheat Chy, Sophy Sum, Sarorn Nhem, Sina Bouchier, Christiane Tichit, Magali Christophel, Eva Taylor, Walter R. J. Baird, John Kevin Menard, Didier Performance of the CareStart™ G6PD Deficiency Screening Test, a Point-of-Care Diagnostic for Primaquine Therapy Screening |
title | Performance of the CareStart™ G6PD Deficiency Screening Test, a Point-of-Care Diagnostic for Primaquine Therapy Screening |
title_full | Performance of the CareStart™ G6PD Deficiency Screening Test, a Point-of-Care Diagnostic for Primaquine Therapy Screening |
title_fullStr | Performance of the CareStart™ G6PD Deficiency Screening Test, a Point-of-Care Diagnostic for Primaquine Therapy Screening |
title_full_unstemmed | Performance of the CareStart™ G6PD Deficiency Screening Test, a Point-of-Care Diagnostic for Primaquine Therapy Screening |
title_short | Performance of the CareStart™ G6PD Deficiency Screening Test, a Point-of-Care Diagnostic for Primaquine Therapy Screening |
title_sort | performance of the carestart™ g6pd deficiency screening test, a point-of-care diagnostic for primaquine therapy screening |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3229584/ https://www.ncbi.nlm.nih.gov/pubmed/22164279 http://dx.doi.org/10.1371/journal.pone.0028357 |
work_keys_str_mv | AT kimsaorin performanceofthecarestartg6pddeficiencyscreeningtestapointofcarediagnosticforprimaquinetherapyscreening AT nguonchea performanceofthecarestartg6pddeficiencyscreeningtestapointofcarediagnosticforprimaquinetherapyscreening AT guillardbertrand performanceofthecarestartg6pddeficiencyscreeningtestapointofcarediagnosticforprimaquinetherapyscreening AT duongsocheat performanceofthecarestartg6pddeficiencyscreeningtestapointofcarediagnosticforprimaquinetherapyscreening AT chysophy performanceofthecarestartg6pddeficiencyscreeningtestapointofcarediagnosticforprimaquinetherapyscreening AT sumsarorn performanceofthecarestartg6pddeficiencyscreeningtestapointofcarediagnosticforprimaquinetherapyscreening AT nhemsina performanceofthecarestartg6pddeficiencyscreeningtestapointofcarediagnosticforprimaquinetherapyscreening AT bouchierchristiane performanceofthecarestartg6pddeficiencyscreeningtestapointofcarediagnosticforprimaquinetherapyscreening AT tichitmagali performanceofthecarestartg6pddeficiencyscreeningtestapointofcarediagnosticforprimaquinetherapyscreening AT christopheleva performanceofthecarestartg6pddeficiencyscreeningtestapointofcarediagnosticforprimaquinetherapyscreening AT taylorwalterrj performanceofthecarestartg6pddeficiencyscreeningtestapointofcarediagnosticforprimaquinetherapyscreening AT bairdjohnkevin performanceofthecarestartg6pddeficiencyscreeningtestapointofcarediagnosticforprimaquinetherapyscreening AT menarddidier performanceofthecarestartg6pddeficiencyscreeningtestapointofcarediagnosticforprimaquinetherapyscreening |