Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR

OBJECTIVES: To examine the feasibility and value of 7 T 3D T2-weighted Fluid Attenuated Inversion Recovery (FLAIR) and Double Inversion Recovery (DIR) MR sequences for lesion detection in multiple sclerosis (MS). METHODS: High-resolution 3D-FLAIR and 3D-DIR MR sequences at 7 T were obtained using ma...

Descripción completa

Detalles Bibliográficos
Autores principales: de Graaf, Wolter L., Zwanenburg, Jaco J. M., Visser, Fredy, Wattjes, Mike P., Pouwels, Petra J. W., Geurts, Jeroen J. G., Polman, Chris H., Barkhof, Frederik, Luijten, Peter R., Castelijns, Jonas A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer-Verlag 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3229693/
https://www.ncbi.nlm.nih.gov/pubmed/21874361
http://dx.doi.org/10.1007/s00330-011-2242-z
_version_ 1782217982128160768
author de Graaf, Wolter L.
Zwanenburg, Jaco J. M.
Visser, Fredy
Wattjes, Mike P.
Pouwels, Petra J. W.
Geurts, Jeroen J. G.
Polman, Chris H.
Barkhof, Frederik
Luijten, Peter R.
Castelijns, Jonas A.
author_facet de Graaf, Wolter L.
Zwanenburg, Jaco J. M.
Visser, Fredy
Wattjes, Mike P.
Pouwels, Petra J. W.
Geurts, Jeroen J. G.
Polman, Chris H.
Barkhof, Frederik
Luijten, Peter R.
Castelijns, Jonas A.
author_sort de Graaf, Wolter L.
collection PubMed
description OBJECTIVES: To examine the feasibility and value of 7 T 3D T2-weighted Fluid Attenuated Inversion Recovery (FLAIR) and Double Inversion Recovery (DIR) MR sequences for lesion detection in multiple sclerosis (MS). METHODS: High-resolution 3D-FLAIR and 3D-DIR MR sequences at 7 T were obtained using magnetisation preparation (MP), and compared with 2D-T2-weighted and 3D-T1-weighted sequences in 10 MS patients and five healthy controls. We determined contrast ratios and counted lesions according to anatomical location. RESULTS: MR imaging at 7 T was safe and allowed multi-contrast imaging within clinically acceptable imaging times. Lesion to white matter (WM) and grey matter (GM) contrast ratios were higher in 3D-MP-FLAIR and 3D-MP-DIR compared with 2D-T2 and 3D-T1. Cortical (mixed+intra-cortical) and total lesion counts were 97/592 on 3D-MP-FLAIR and 100/558 on 3D-MP-DIR compared with 84/384 on 2D-T2 and 42/442 on 3D-T1. More juxta-cortical lesions were seen with 3D-MP-FLAIR (205) and 3D-MP-DIR (133) than with 2D-T2 (125) and 3D-T1 (70). Finally, higher numbers of lesions were found for deep WM lesions: 176 for 3D-MP-FLAIR and 196 for 3D-MP-DIR vs. 155 for 2D-T2 and 131 for 3D-T1. CONCLUSIONS: Near isotropic 3D-MP-FLAIR and 3D-MP-DIR allows high quality T2-weighted MR imaging in MS at 7 T, improving (cortical) lesion detection. Key Points • Magnetization prepared 3D-FLAIR and 3D-DIR 7 T MRI provide high quality isotropic images. • MS lesions are well demonstrated by 3D-MP-FLAIR and 3D-MP-DIR at 7 T MRI. • 3D-MP-FLAIR and 3D-MP-DIR at 7 T MRI show many more Virchov-Robin spaces.
format Online
Article
Text
id pubmed-3229693
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-32296932011-12-27 Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR de Graaf, Wolter L. Zwanenburg, Jaco J. M. Visser, Fredy Wattjes, Mike P. Pouwels, Petra J. W. Geurts, Jeroen J. G. Polman, Chris H. Barkhof, Frederik Luijten, Peter R. Castelijns, Jonas A. Eur Radiol Magnetic Resonance OBJECTIVES: To examine the feasibility and value of 7 T 3D T2-weighted Fluid Attenuated Inversion Recovery (FLAIR) and Double Inversion Recovery (DIR) MR sequences for lesion detection in multiple sclerosis (MS). METHODS: High-resolution 3D-FLAIR and 3D-DIR MR sequences at 7 T were obtained using magnetisation preparation (MP), and compared with 2D-T2-weighted and 3D-T1-weighted sequences in 10 MS patients and five healthy controls. We determined contrast ratios and counted lesions according to anatomical location. RESULTS: MR imaging at 7 T was safe and allowed multi-contrast imaging within clinically acceptable imaging times. Lesion to white matter (WM) and grey matter (GM) contrast ratios were higher in 3D-MP-FLAIR and 3D-MP-DIR compared with 2D-T2 and 3D-T1. Cortical (mixed+intra-cortical) and total lesion counts were 97/592 on 3D-MP-FLAIR and 100/558 on 3D-MP-DIR compared with 84/384 on 2D-T2 and 42/442 on 3D-T1. More juxta-cortical lesions were seen with 3D-MP-FLAIR (205) and 3D-MP-DIR (133) than with 2D-T2 (125) and 3D-T1 (70). Finally, higher numbers of lesions were found for deep WM lesions: 176 for 3D-MP-FLAIR and 196 for 3D-MP-DIR vs. 155 for 2D-T2 and 131 for 3D-T1. CONCLUSIONS: Near isotropic 3D-MP-FLAIR and 3D-MP-DIR allows high quality T2-weighted MR imaging in MS at 7 T, improving (cortical) lesion detection. Key Points • Magnetization prepared 3D-FLAIR and 3D-DIR 7 T MRI provide high quality isotropic images. • MS lesions are well demonstrated by 3D-MP-FLAIR and 3D-MP-DIR at 7 T MRI. • 3D-MP-FLAIR and 3D-MP-DIR at 7 T MRI show many more Virchov-Robin spaces. Springer-Verlag 2011-08-27 2012 /pmc/articles/PMC3229693/ /pubmed/21874361 http://dx.doi.org/10.1007/s00330-011-2242-z Text en © The Author(s) 2011 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Magnetic Resonance
de Graaf, Wolter L.
Zwanenburg, Jaco J. M.
Visser, Fredy
Wattjes, Mike P.
Pouwels, Petra J. W.
Geurts, Jeroen J. G.
Polman, Chris H.
Barkhof, Frederik
Luijten, Peter R.
Castelijns, Jonas A.
Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR
title Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR
title_full Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR
title_fullStr Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR
title_full_unstemmed Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR
title_short Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR
title_sort lesion detection at seven tesla in multiple sclerosis using magnetisation prepared 3d-flair and 3d-dir
topic Magnetic Resonance
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3229693/
https://www.ncbi.nlm.nih.gov/pubmed/21874361
http://dx.doi.org/10.1007/s00330-011-2242-z
work_keys_str_mv AT degraafwolterl lesiondetectionatseventeslainmultiplesclerosisusingmagnetisationprepared3dflairand3ddir
AT zwanenburgjacojm lesiondetectionatseventeslainmultiplesclerosisusingmagnetisationprepared3dflairand3ddir
AT visserfredy lesiondetectionatseventeslainmultiplesclerosisusingmagnetisationprepared3dflairand3ddir
AT wattjesmikep lesiondetectionatseventeslainmultiplesclerosisusingmagnetisationprepared3dflairand3ddir
AT pouwelspetrajw lesiondetectionatseventeslainmultiplesclerosisusingmagnetisationprepared3dflairand3ddir
AT geurtsjeroenjg lesiondetectionatseventeslainmultiplesclerosisusingmagnetisationprepared3dflairand3ddir
AT polmanchrish lesiondetectionatseventeslainmultiplesclerosisusingmagnetisationprepared3dflairand3ddir
AT barkhoffrederik lesiondetectionatseventeslainmultiplesclerosisusingmagnetisationprepared3dflairand3ddir
AT luijtenpeterr lesiondetectionatseventeslainmultiplesclerosisusingmagnetisationprepared3dflairand3ddir
AT castelijnsjonasa lesiondetectionatseventeslainmultiplesclerosisusingmagnetisationprepared3dflairand3ddir