A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems: 55 hips followed for 2 years with RSA and DXA
BACKGROUND AND PURPOSE: Plasma-sprayed hydroxyapatite (HA) is a successful coating for fixation of uncemented femoral stems. There may be alternative coatings with advantages in bone remodeling and transport of bone-active substances. We investigated whether an electrochemically deposited hydroxyapa...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Informa Healthcare
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3229992/ https://www.ncbi.nlm.nih.gov/pubmed/21189109 http://dx.doi.org/10.3109/17453674.2010.548027 |
_version_ | 1782218017427423232 |
---|---|
author | Bøe, Berte Grimsmo Röhrl, Stephan M Heier, Tore Snorrason, Finnur Nordsletten, Lars |
author_facet | Bøe, Berte Grimsmo Röhrl, Stephan M Heier, Tore Snorrason, Finnur Nordsletten, Lars |
author_sort | Bøe, Berte Grimsmo |
collection | PubMed |
description | BACKGROUND AND PURPOSE: Plasma-sprayed hydroxyapatite (HA) is a successful coating for fixation of uncemented femoral stems. There may be alternative coatings with advantages in bone remodeling and transport of bone-active substances. We investigated whether an electrochemically deposited hydroxyapatite, Bonemaster (BM), might be a safe alternative in total hip arthroplasty. Our hypothesis was that the new coating would not be inferior to the conventional one. PATIENTS AND METHODS: 50 patients (55 hips) were included. The stem was tapered and porous-coated proximally. On top of the porous coating was either HA or BM. Patients were evaluated postoperatively and after 3, 6, 12, and 24 months to measure fixation by radiostereometric analysis (RSA), bone mineral density by dual-energy X-ray absorptiometry (DXA), and conventional radiography. Clinical evaluation was performed with Harris hip score and Oxford hip score, both preoperatively and after 2 years. RESULTS: After 2 years, the stems had subsided 0.25 (HA) and 0.28 (BM) mm and there were no statistically significant differences between the groups in any direction, regarding both migration and rotation. The BM group retained significantly more bone than the HA group in Gruen zone 1 during the first 2 years. The Harris and Oxford hip scores were similar in both groups. INTERPRETATION: Electrochemically deposited hydroxyapatite on an uncemented stem does not appear to be inferior to plasma-sprayed HA regarding clinical and radiological results, bone remodeling, and micromotion after 2 years follow-up. |
format | Online Article Text |
id | pubmed-3229992 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Informa Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-32299922012-01-03 A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems: 55 hips followed for 2 years with RSA and DXA Bøe, Berte Grimsmo Röhrl, Stephan M Heier, Tore Snorrason, Finnur Nordsletten, Lars Acta Orthop Article BACKGROUND AND PURPOSE: Plasma-sprayed hydroxyapatite (HA) is a successful coating for fixation of uncemented femoral stems. There may be alternative coatings with advantages in bone remodeling and transport of bone-active substances. We investigated whether an electrochemically deposited hydroxyapatite, Bonemaster (BM), might be a safe alternative in total hip arthroplasty. Our hypothesis was that the new coating would not be inferior to the conventional one. PATIENTS AND METHODS: 50 patients (55 hips) were included. The stem was tapered and porous-coated proximally. On top of the porous coating was either HA or BM. Patients were evaluated postoperatively and after 3, 6, 12, and 24 months to measure fixation by radiostereometric analysis (RSA), bone mineral density by dual-energy X-ray absorptiometry (DXA), and conventional radiography. Clinical evaluation was performed with Harris hip score and Oxford hip score, both preoperatively and after 2 years. RESULTS: After 2 years, the stems had subsided 0.25 (HA) and 0.28 (BM) mm and there were no statistically significant differences between the groups in any direction, regarding both migration and rotation. The BM group retained significantly more bone than the HA group in Gruen zone 1 during the first 2 years. The Harris and Oxford hip scores were similar in both groups. INTERPRETATION: Electrochemically deposited hydroxyapatite on an uncemented stem does not appear to be inferior to plasma-sprayed HA regarding clinical and radiological results, bone remodeling, and micromotion after 2 years follow-up. Informa Healthcare 2011-02 2011-02-10 /pmc/articles/PMC3229992/ /pubmed/21189109 http://dx.doi.org/10.3109/17453674.2010.548027 Text en Copyright: © Nordic Orthopaedic Federation http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited. |
spellingShingle | Article Bøe, Berte Grimsmo Röhrl, Stephan M Heier, Tore Snorrason, Finnur Nordsletten, Lars A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems: 55 hips followed for 2 years with RSA and DXA |
title | A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems: 55 hips followed for 2 years with RSA and DXA |
title_full | A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems: 55 hips followed for 2 years with RSA and DXA |
title_fullStr | A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems: 55 hips followed for 2 years with RSA and DXA |
title_full_unstemmed | A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems: 55 hips followed for 2 years with RSA and DXA |
title_short | A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems: 55 hips followed for 2 years with RSA and DXA |
title_sort | prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems: 55 hips followed for 2 years with rsa and dxa |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3229992/ https://www.ncbi.nlm.nih.gov/pubmed/21189109 http://dx.doi.org/10.3109/17453674.2010.548027 |
work_keys_str_mv | AT bøebertegrimsmo aprospectiverandomizedstudycomparingelectrochemicallydepositedhydroxyapatiteandplasmasprayedhydroxyapatiteontitaniumstems55hipsfollowedfor2yearswithrsaanddxa AT rohrlstephanm aprospectiverandomizedstudycomparingelectrochemicallydepositedhydroxyapatiteandplasmasprayedhydroxyapatiteontitaniumstems55hipsfollowedfor2yearswithrsaanddxa AT heiertore aprospectiverandomizedstudycomparingelectrochemicallydepositedhydroxyapatiteandplasmasprayedhydroxyapatiteontitaniumstems55hipsfollowedfor2yearswithrsaanddxa AT snorrasonfinnur aprospectiverandomizedstudycomparingelectrochemicallydepositedhydroxyapatiteandplasmasprayedhydroxyapatiteontitaniumstems55hipsfollowedfor2yearswithrsaanddxa AT nordslettenlars aprospectiverandomizedstudycomparingelectrochemicallydepositedhydroxyapatiteandplasmasprayedhydroxyapatiteontitaniumstems55hipsfollowedfor2yearswithrsaanddxa AT bøebertegrimsmo prospectiverandomizedstudycomparingelectrochemicallydepositedhydroxyapatiteandplasmasprayedhydroxyapatiteontitaniumstems55hipsfollowedfor2yearswithrsaanddxa AT rohrlstephanm prospectiverandomizedstudycomparingelectrochemicallydepositedhydroxyapatiteandplasmasprayedhydroxyapatiteontitaniumstems55hipsfollowedfor2yearswithrsaanddxa AT heiertore prospectiverandomizedstudycomparingelectrochemicallydepositedhydroxyapatiteandplasmasprayedhydroxyapatiteontitaniumstems55hipsfollowedfor2yearswithrsaanddxa AT snorrasonfinnur prospectiverandomizedstudycomparingelectrochemicallydepositedhydroxyapatiteandplasmasprayedhydroxyapatiteontitaniumstems55hipsfollowedfor2yearswithrsaanddxa AT nordslettenlars prospectiverandomizedstudycomparingelectrochemicallydepositedhydroxyapatiteandplasmasprayedhydroxyapatiteontitaniumstems55hipsfollowedfor2yearswithrsaanddxa |