Cargando…

An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines

This paper presents an original non-invasive procedure for the diagnosis of electromagnetic devices, as well as AC electrical rotating machines using two external flux coil sensors that measure the external magnetic field in the machines’ vicinity. The diagnosis exploits the signal delivered by the...

Descripción completa

Detalles Bibliográficos
Autores principales: Pusca, Remus, Romary, Raphael, Ceban, Andrian, Brudny, Jean-François
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3230988/
https://www.ncbi.nlm.nih.gov/pubmed/22163480
http://dx.doi.org/10.3390/s101110448
_version_ 1782218117514002432
author Pusca, Remus
Romary, Raphael
Ceban, Andrian
Brudny, Jean-François
author_facet Pusca, Remus
Romary, Raphael
Ceban, Andrian
Brudny, Jean-François
author_sort Pusca, Remus
collection PubMed
description This paper presents an original non-invasive procedure for the diagnosis of electromagnetic devices, as well as AC electrical rotating machines using two external flux coil sensors that measure the external magnetic field in the machines’ vicinity. The diagnosis exploits the signal delivered by the two sensors placed in particular positions. Contrary to classical methods using only one sensor, the presented method does not require any knowledge of a presumed machine’s healthy former state. On the other hand, the loading operating is not a disturbing factor but it is used to the fault discrimination. In order to present this procedure, an internal stator inter-turn short-circuit fault is considered as well.
format Online
Article
Text
id pubmed-3230988
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32309882011-12-07 An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines Pusca, Remus Romary, Raphael Ceban, Andrian Brudny, Jean-François Sensors (Basel) Article This paper presents an original non-invasive procedure for the diagnosis of electromagnetic devices, as well as AC electrical rotating machines using two external flux coil sensors that measure the external magnetic field in the machines’ vicinity. The diagnosis exploits the signal delivered by the two sensors placed in particular positions. Contrary to classical methods using only one sensor, the presented method does not require any knowledge of a presumed machine’s healthy former state. On the other hand, the loading operating is not a disturbing factor but it is used to the fault discrimination. In order to present this procedure, an internal stator inter-turn short-circuit fault is considered as well. Molecular Diversity Preservation International (MDPI) 2010-11-18 /pmc/articles/PMC3230988/ /pubmed/22163480 http://dx.doi.org/10.3390/s101110448 Text en © 2010 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/. (http://creativecommons.org/licenses/by/3.0/) )
spellingShingle Article
Pusca, Remus
Romary, Raphael
Ceban, Andrian
Brudny, Jean-François
An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines
title An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines
title_full An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines
title_fullStr An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines
title_full_unstemmed An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines
title_short An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines
title_sort online universal diagnosis procedure using two external flux sensors applied to the ac electrical rotating machines
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3230988/
https://www.ncbi.nlm.nih.gov/pubmed/22163480
http://dx.doi.org/10.3390/s101110448
work_keys_str_mv AT puscaremus anonlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines
AT romaryraphael anonlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines
AT cebanandrian anonlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines
AT brudnyjeanfrancois anonlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines
AT puscaremus onlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines
AT romaryraphael onlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines
AT cebanandrian onlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines
AT brudnyjeanfrancois onlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines