Cargando…
An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines
This paper presents an original non-invasive procedure for the diagnosis of electromagnetic devices, as well as AC electrical rotating machines using two external flux coil sensors that measure the external magnetic field in the machines’ vicinity. The diagnosis exploits the signal delivered by the...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3230988/ https://www.ncbi.nlm.nih.gov/pubmed/22163480 http://dx.doi.org/10.3390/s101110448 |
_version_ | 1782218117514002432 |
---|---|
author | Pusca, Remus Romary, Raphael Ceban, Andrian Brudny, Jean-François |
author_facet | Pusca, Remus Romary, Raphael Ceban, Andrian Brudny, Jean-François |
author_sort | Pusca, Remus |
collection | PubMed |
description | This paper presents an original non-invasive procedure for the diagnosis of electromagnetic devices, as well as AC electrical rotating machines using two external flux coil sensors that measure the external magnetic field in the machines’ vicinity. The diagnosis exploits the signal delivered by the two sensors placed in particular positions. Contrary to classical methods using only one sensor, the presented method does not require any knowledge of a presumed machine’s healthy former state. On the other hand, the loading operating is not a disturbing factor but it is used to the fault discrimination. In order to present this procedure, an internal stator inter-turn short-circuit fault is considered as well. |
format | Online Article Text |
id | pubmed-3230988 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-32309882011-12-07 An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines Pusca, Remus Romary, Raphael Ceban, Andrian Brudny, Jean-François Sensors (Basel) Article This paper presents an original non-invasive procedure for the diagnosis of electromagnetic devices, as well as AC electrical rotating machines using two external flux coil sensors that measure the external magnetic field in the machines’ vicinity. The diagnosis exploits the signal delivered by the two sensors placed in particular positions. Contrary to classical methods using only one sensor, the presented method does not require any knowledge of a presumed machine’s healthy former state. On the other hand, the loading operating is not a disturbing factor but it is used to the fault discrimination. In order to present this procedure, an internal stator inter-turn short-circuit fault is considered as well. Molecular Diversity Preservation International (MDPI) 2010-11-18 /pmc/articles/PMC3230988/ /pubmed/22163480 http://dx.doi.org/10.3390/s101110448 Text en © 2010 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/. (http://creativecommons.org/licenses/by/3.0/) ) |
spellingShingle | Article Pusca, Remus Romary, Raphael Ceban, Andrian Brudny, Jean-François An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines |
title | An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines |
title_full | An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines |
title_fullStr | An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines |
title_full_unstemmed | An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines |
title_short | An Online Universal Diagnosis Procedure Using Two External Flux Sensors Applied to the AC Electrical Rotating Machines |
title_sort | online universal diagnosis procedure using two external flux sensors applied to the ac electrical rotating machines |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3230988/ https://www.ncbi.nlm.nih.gov/pubmed/22163480 http://dx.doi.org/10.3390/s101110448 |
work_keys_str_mv | AT puscaremus anonlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines AT romaryraphael anonlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines AT cebanandrian anonlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines AT brudnyjeanfrancois anonlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines AT puscaremus onlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines AT romaryraphael onlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines AT cebanandrian onlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines AT brudnyjeanfrancois onlineuniversaldiagnosisprocedureusingtwoexternalfluxsensorsappliedtotheacelectricalrotatingmachines |