Cargando…

Sensitivities of a Standard Test Method for the Determination of the pHe of Bioethanol and Suggestions for Improvement

An assessment of the sensitivities of the critical parameters in the ASTM D6423 documentary standard method for the measurement of pHe in (bio)ethanol has been undertaken. Repeatability of measurements made using the same glass electrode and reproducibility between different glass electrodes have be...

Descripción completa

Detalles Bibliográficos
Autores principales: Brown, Richard J. C., Keates, Adam C., Brewer, Paul J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231013/
https://www.ncbi.nlm.nih.gov/pubmed/22163451
http://dx.doi.org/10.3390/s101109982
_version_ 1782218123440553984
author Brown, Richard J. C.
Keates, Adam C.
Brewer, Paul J.
author_facet Brown, Richard J. C.
Keates, Adam C.
Brewer, Paul J.
author_sort Brown, Richard J. C.
collection PubMed
description An assessment of the sensitivities of the critical parameters in the ASTM D6423 documentary standard method for the measurement of pHe in (bio)ethanol has been undertaken. Repeatability of measurements made using the same glass electrode and reproducibility between different glass electrodes have been identified as the main contributors to the uncertainty of the values produced. Strategies to reduce the uncertainty of the measurement have been identified and tested. Both increasing the time after which the pHe measurement is made following immersion in the sample, and rinsing the glass electrode with ethanol prior to immersion in the sample, have been shown to be effective in reducing the uncertainty of the numerical value produced. However, it is acknowledged that the values produced using these modified approaches may not be directly compared with those obtained using the documentary ASTM method since pHe is defined operationally by the process used to measure it.
format Online
Article
Text
id pubmed-3231013
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32310132011-12-07 Sensitivities of a Standard Test Method for the Determination of the pHe of Bioethanol and Suggestions for Improvement Brown, Richard J. C. Keates, Adam C. Brewer, Paul J. Sensors (Basel) Article An assessment of the sensitivities of the critical parameters in the ASTM D6423 documentary standard method for the measurement of pHe in (bio)ethanol has been undertaken. Repeatability of measurements made using the same glass electrode and reproducibility between different glass electrodes have been identified as the main contributors to the uncertainty of the values produced. Strategies to reduce the uncertainty of the measurement have been identified and tested. Both increasing the time after which the pHe measurement is made following immersion in the sample, and rinsing the glass electrode with ethanol prior to immersion in the sample, have been shown to be effective in reducing the uncertainty of the numerical value produced. However, it is acknowledged that the values produced using these modified approaches may not be directly compared with those obtained using the documentary ASTM method since pHe is defined operationally by the process used to measure it. Molecular Diversity Preservation International (MDPI) 2010-11-09 /pmc/articles/PMC3231013/ /pubmed/22163451 http://dx.doi.org/10.3390/s101109982 Text en © 2010 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/. (http://creativecommons.org/licenses/by/3.0/) )
spellingShingle Article
Brown, Richard J. C.
Keates, Adam C.
Brewer, Paul J.
Sensitivities of a Standard Test Method for the Determination of the pHe of Bioethanol and Suggestions for Improvement
title Sensitivities of a Standard Test Method for the Determination of the pHe of Bioethanol and Suggestions for Improvement
title_full Sensitivities of a Standard Test Method for the Determination of the pHe of Bioethanol and Suggestions for Improvement
title_fullStr Sensitivities of a Standard Test Method for the Determination of the pHe of Bioethanol and Suggestions for Improvement
title_full_unstemmed Sensitivities of a Standard Test Method for the Determination of the pHe of Bioethanol and Suggestions for Improvement
title_short Sensitivities of a Standard Test Method for the Determination of the pHe of Bioethanol and Suggestions for Improvement
title_sort sensitivities of a standard test method for the determination of the phe of bioethanol and suggestions for improvement
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231013/
https://www.ncbi.nlm.nih.gov/pubmed/22163451
http://dx.doi.org/10.3390/s101109982
work_keys_str_mv AT brownrichardjc sensitivitiesofastandardtestmethodforthedeterminationofthepheofbioethanolandsuggestionsforimprovement
AT keatesadamc sensitivitiesofastandardtestmethodforthedeterminationofthepheofbioethanolandsuggestionsforimprovement
AT brewerpaulj sensitivitiesofastandardtestmethodforthedeterminationofthepheofbioethanolandsuggestionsforimprovement