Cargando…
Performance Evaluation of an Infrared Thermocouple
The measurement of the leaf temperature of forests or agricultural plants is an important technique for the monitoring of the physiological state of crops. The infrared thermometer is a convenient device due to its fast response and nondestructive measurement technique. Nowadays, a novel infrared th...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231037/ https://www.ncbi.nlm.nih.gov/pubmed/22163458 http://dx.doi.org/10.3390/s101110081 |
_version_ | 1782218129109155840 |
---|---|
author | Chen, Chiachung Weng, Yu-Kai Shen, Te-Ching |
author_facet | Chen, Chiachung Weng, Yu-Kai Shen, Te-Ching |
author_sort | Chen, Chiachung |
collection | PubMed |
description | The measurement of the leaf temperature of forests or agricultural plants is an important technique for the monitoring of the physiological state of crops. The infrared thermometer is a convenient device due to its fast response and nondestructive measurement technique. Nowadays, a novel infrared thermocouple, developed with the same measurement principle of the infrared thermometer but using a different detector, has been commercialized for non-contact temperature measurement. The performances of two-kinds of infrared thermocouples were evaluated in this study. The standard temperature was maintained by a temperature calibrator and a special black cavity device. The results indicated that both types of infrared thermocouples had good precision. The error distribution ranged from −1.8 °C to 18 °C as the reading values served as the true values. Within the range from 13 °C to 37 °C, the adequate calibration equations were the high-order polynomial equations. Within the narrower range from 20 °C to 35 °C, the adequate equation was a linear equation for one sensor and a two-order polynomial equation for the other sensor. The accuracy of the two kinds of infrared thermocouple was improved by nearly 0.4 °C with the calibration equations. These devices could serve as mobile monitoring tools for in situ and real time routine estimation of leaf temperatures. |
format | Online Article Text |
id | pubmed-3231037 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-32310372011-12-07 Performance Evaluation of an Infrared Thermocouple Chen, Chiachung Weng, Yu-Kai Shen, Te-Ching Sensors (Basel) Article The measurement of the leaf temperature of forests or agricultural plants is an important technique for the monitoring of the physiological state of crops. The infrared thermometer is a convenient device due to its fast response and nondestructive measurement technique. Nowadays, a novel infrared thermocouple, developed with the same measurement principle of the infrared thermometer but using a different detector, has been commercialized for non-contact temperature measurement. The performances of two-kinds of infrared thermocouples were evaluated in this study. The standard temperature was maintained by a temperature calibrator and a special black cavity device. The results indicated that both types of infrared thermocouples had good precision. The error distribution ranged from −1.8 °C to 18 °C as the reading values served as the true values. Within the range from 13 °C to 37 °C, the adequate calibration equations were the high-order polynomial equations. Within the narrower range from 20 °C to 35 °C, the adequate equation was a linear equation for one sensor and a two-order polynomial equation for the other sensor. The accuracy of the two kinds of infrared thermocouple was improved by nearly 0.4 °C with the calibration equations. These devices could serve as mobile monitoring tools for in situ and real time routine estimation of leaf temperatures. Molecular Diversity Preservation International (MDPI) 2010-11-10 /pmc/articles/PMC3231037/ /pubmed/22163458 http://dx.doi.org/10.3390/s101110081 Text en © 2010 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/. (http://creativecommons.org/licenses/by/3.0/) ) |
spellingShingle | Article Chen, Chiachung Weng, Yu-Kai Shen, Te-Ching Performance Evaluation of an Infrared Thermocouple |
title | Performance Evaluation of an Infrared Thermocouple |
title_full | Performance Evaluation of an Infrared Thermocouple |
title_fullStr | Performance Evaluation of an Infrared Thermocouple |
title_full_unstemmed | Performance Evaluation of an Infrared Thermocouple |
title_short | Performance Evaluation of an Infrared Thermocouple |
title_sort | performance evaluation of an infrared thermocouple |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231037/ https://www.ncbi.nlm.nih.gov/pubmed/22163458 http://dx.doi.org/10.3390/s101110081 |
work_keys_str_mv | AT chenchiachung performanceevaluationofaninfraredthermocouple AT wengyukai performanceevaluationofaninfraredthermocouple AT shenteching performanceevaluationofaninfraredthermocouple |