Cargando…

Performance Evaluation of an Infrared Thermocouple

The measurement of the leaf temperature of forests or agricultural plants is an important technique for the monitoring of the physiological state of crops. The infrared thermometer is a convenient device due to its fast response and nondestructive measurement technique. Nowadays, a novel infrared th...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Chiachung, Weng, Yu-Kai, Shen, Te-Ching
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231037/
https://www.ncbi.nlm.nih.gov/pubmed/22163458
http://dx.doi.org/10.3390/s101110081
_version_ 1782218129109155840
author Chen, Chiachung
Weng, Yu-Kai
Shen, Te-Ching
author_facet Chen, Chiachung
Weng, Yu-Kai
Shen, Te-Ching
author_sort Chen, Chiachung
collection PubMed
description The measurement of the leaf temperature of forests or agricultural plants is an important technique for the monitoring of the physiological state of crops. The infrared thermometer is a convenient device due to its fast response and nondestructive measurement technique. Nowadays, a novel infrared thermocouple, developed with the same measurement principle of the infrared thermometer but using a different detector, has been commercialized for non-contact temperature measurement. The performances of two-kinds of infrared thermocouples were evaluated in this study. The standard temperature was maintained by a temperature calibrator and a special black cavity device. The results indicated that both types of infrared thermocouples had good precision. The error distribution ranged from −1.8 °C to 18 °C as the reading values served as the true values. Within the range from 13 °C to 37 °C, the adequate calibration equations were the high-order polynomial equations. Within the narrower range from 20 °C to 35 °C, the adequate equation was a linear equation for one sensor and a two-order polynomial equation for the other sensor. The accuracy of the two kinds of infrared thermocouple was improved by nearly 0.4 °C with the calibration equations. These devices could serve as mobile monitoring tools for in situ and real time routine estimation of leaf temperatures.
format Online
Article
Text
id pubmed-3231037
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32310372011-12-07 Performance Evaluation of an Infrared Thermocouple Chen, Chiachung Weng, Yu-Kai Shen, Te-Ching Sensors (Basel) Article The measurement of the leaf temperature of forests or agricultural plants is an important technique for the monitoring of the physiological state of crops. The infrared thermometer is a convenient device due to its fast response and nondestructive measurement technique. Nowadays, a novel infrared thermocouple, developed with the same measurement principle of the infrared thermometer but using a different detector, has been commercialized for non-contact temperature measurement. The performances of two-kinds of infrared thermocouples were evaluated in this study. The standard temperature was maintained by a temperature calibrator and a special black cavity device. The results indicated that both types of infrared thermocouples had good precision. The error distribution ranged from −1.8 °C to 18 °C as the reading values served as the true values. Within the range from 13 °C to 37 °C, the adequate calibration equations were the high-order polynomial equations. Within the narrower range from 20 °C to 35 °C, the adequate equation was a linear equation for one sensor and a two-order polynomial equation for the other sensor. The accuracy of the two kinds of infrared thermocouple was improved by nearly 0.4 °C with the calibration equations. These devices could serve as mobile monitoring tools for in situ and real time routine estimation of leaf temperatures. Molecular Diversity Preservation International (MDPI) 2010-11-10 /pmc/articles/PMC3231037/ /pubmed/22163458 http://dx.doi.org/10.3390/s101110081 Text en © 2010 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/. (http://creativecommons.org/licenses/by/3.0/) )
spellingShingle Article
Chen, Chiachung
Weng, Yu-Kai
Shen, Te-Ching
Performance Evaluation of an Infrared Thermocouple
title Performance Evaluation of an Infrared Thermocouple
title_full Performance Evaluation of an Infrared Thermocouple
title_fullStr Performance Evaluation of an Infrared Thermocouple
title_full_unstemmed Performance Evaluation of an Infrared Thermocouple
title_short Performance Evaluation of an Infrared Thermocouple
title_sort performance evaluation of an infrared thermocouple
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231037/
https://www.ncbi.nlm.nih.gov/pubmed/22163458
http://dx.doi.org/10.3390/s101110081
work_keys_str_mv AT chenchiachung performanceevaluationofaninfraredthermocouple
AT wengyukai performanceevaluationofaninfraredthermocouple
AT shenteching performanceevaluationofaninfraredthermocouple