Cargando…
A New Approach to Laminar Flowmeters
After studying the performance and characteristics of actual laminar flowmeters a new disposition for this type of sensors is proposed in such a way that the measurement errors introduced by the intrinsic nature of the device can be minimized. The preliminary study shows that the developing entry re...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231082/ https://www.ncbi.nlm.nih.gov/pubmed/22163486 http://dx.doi.org/10.3390/s101210560 |
_version_ | 1782218139842379776 |
---|---|
author | Pena, Fernando Lopez Diaz, Alvaro Deibe Lema, Marcos Rodriguez Rodriguez, Santiago Vazquez |
author_facet | Pena, Fernando Lopez Diaz, Alvaro Deibe Lema, Marcos Rodriguez Rodriguez, Santiago Vazquez |
author_sort | Pena, Fernando Lopez |
collection | PubMed |
description | After studying the performance and characteristics of actual laminar flowmeters a new disposition for this type of sensors is proposed in such a way that the measurement errors introduced by the intrinsic nature of the device can be minimized. The preliminary study shows that the developing entry region introduces non-linearity effects in all these devices. These effects bring about not only errors, but also a change in the slope of the linear calibration respect of the Poiseuille relation. After a subsequent analysis on how these non-linearity errors can be reduced, a new disposition of this type of flowmeters is introduced. This device makes used of flow elements having pressure taps at three locations along its length and connected to three isolated chambers. In this way, the static pressure can be measured at three locations and contributed to by the pressure taps at the level of each chamber. Thus the linearization error is reduced with an additional advantage of producing a reduced pressure drop. |
format | Online Article Text |
id | pubmed-3231082 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-32310822011-12-07 A New Approach to Laminar Flowmeters Pena, Fernando Lopez Diaz, Alvaro Deibe Lema, Marcos Rodriguez Rodriguez, Santiago Vazquez Sensors (Basel) Article After studying the performance and characteristics of actual laminar flowmeters a new disposition for this type of sensors is proposed in such a way that the measurement errors introduced by the intrinsic nature of the device can be minimized. The preliminary study shows that the developing entry region introduces non-linearity effects in all these devices. These effects bring about not only errors, but also a change in the slope of the linear calibration respect of the Poiseuille relation. After a subsequent analysis on how these non-linearity errors can be reduced, a new disposition of this type of flowmeters is introduced. This device makes used of flow elements having pressure taps at three locations along its length and connected to three isolated chambers. In this way, the static pressure can be measured at three locations and contributed to by the pressure taps at the level of each chamber. Thus the linearization error is reduced with an additional advantage of producing a reduced pressure drop. Molecular Diversity Preservation International (MDPI) 2010-11-29 /pmc/articles/PMC3231082/ /pubmed/22163486 http://dx.doi.org/10.3390/s101210560 Text en © 2010 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Pena, Fernando Lopez Diaz, Alvaro Deibe Lema, Marcos Rodriguez Rodriguez, Santiago Vazquez A New Approach to Laminar Flowmeters |
title | A New Approach to Laminar Flowmeters |
title_full | A New Approach to Laminar Flowmeters |
title_fullStr | A New Approach to Laminar Flowmeters |
title_full_unstemmed | A New Approach to Laminar Flowmeters |
title_short | A New Approach to Laminar Flowmeters |
title_sort | new approach to laminar flowmeters |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231082/ https://www.ncbi.nlm.nih.gov/pubmed/22163486 http://dx.doi.org/10.3390/s101210560 |
work_keys_str_mv | AT penafernandolopez anewapproachtolaminarflowmeters AT diazalvarodeibe anewapproachtolaminarflowmeters AT lemamarcosrodriguez anewapproachtolaminarflowmeters AT rodriguezsantiagovazquez anewapproachtolaminarflowmeters AT penafernandolopez newapproachtolaminarflowmeters AT diazalvarodeibe newapproachtolaminarflowmeters AT lemamarcosrodriguez newapproachtolaminarflowmeters AT rodriguezsantiagovazquez newapproachtolaminarflowmeters |