A Piezoelectric Plethysmograph Sensor Based on a Pt Wire Implanted Lead Lanthanum Zirconate Titanate Bulk Ceramic

This work reports on the development of a Lead Lanthanum Zirconate Titanate (PLZT) bulk ferroelectric poled ceramic structure as a Piezoelectric Plethysmograph (PZPG) sensor. The ceramic was implanted during its fabrication with a platinum (Pt) wire which works as an internal electrode. The ceramic...

Descripción completa

Detalles Bibliográficos
Autores principales: González-Morán, Carlos O., Flores-Cuautle, J.J. Agustín, Suaste-Gómez, Ernesto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231161/
https://www.ncbi.nlm.nih.gov/pubmed/22163596
http://dx.doi.org/10.3390/s100807146
_version_ 1782218157764640768
author González-Morán, Carlos O.
Flores-Cuautle, J.J. Agustín
Suaste-Gómez, Ernesto
author_facet González-Morán, Carlos O.
Flores-Cuautle, J.J. Agustín
Suaste-Gómez, Ernesto
author_sort González-Morán, Carlos O.
collection PubMed
description This work reports on the development of a Lead Lanthanum Zirconate Titanate (PLZT) bulk ferroelectric poled ceramic structure as a Piezoelectric Plethysmograph (PZPG) sensor. The ceramic was implanted during its fabrication with a platinum (Pt) wire which works as an internal electrode. The ceramic was then submitted to an experimental setup in order to validate and determine the Pt-wire mechanical effects. This PZPG sensor was also mounted on a finger splint in order to measure the blood flow that results from the pulsations of blood occurring with each heartbeat. Fingertip pulses were recorded jointly with an ECG signal from a 25 year old male to compare the time shift; the PZPG sensor guarantees the electrical isolation of the patient. The proposed PZPG has several advantages: it can be adjusted for fingertip measurements, but it can easily be extended by means of spare bands, therefore making possible PZPG measurements from different body locations, e.g., forehead, forearm, knee, neck, etc.
format Online
Article
Text
id pubmed-3231161
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32311612011-12-07 A Piezoelectric Plethysmograph Sensor Based on a Pt Wire Implanted Lead Lanthanum Zirconate Titanate Bulk Ceramic González-Morán, Carlos O. Flores-Cuautle, J.J. Agustín Suaste-Gómez, Ernesto Sensors (Basel) Article This work reports on the development of a Lead Lanthanum Zirconate Titanate (PLZT) bulk ferroelectric poled ceramic structure as a Piezoelectric Plethysmograph (PZPG) sensor. The ceramic was implanted during its fabrication with a platinum (Pt) wire which works as an internal electrode. The ceramic was then submitted to an experimental setup in order to validate and determine the Pt-wire mechanical effects. This PZPG sensor was also mounted on a finger splint in order to measure the blood flow that results from the pulsations of blood occurring with each heartbeat. Fingertip pulses were recorded jointly with an ECG signal from a 25 year old male to compare the time shift; the PZPG sensor guarantees the electrical isolation of the patient. The proposed PZPG has several advantages: it can be adjusted for fingertip measurements, but it can easily be extended by means of spare bands, therefore making possible PZPG measurements from different body locations, e.g., forehead, forearm, knee, neck, etc. Molecular Diversity Preservation International (MDPI) 2010-07-29 /pmc/articles/PMC3231161/ /pubmed/22163596 http://dx.doi.org/10.3390/s100807146 Text en © 2010 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
González-Morán, Carlos O.
Flores-Cuautle, J.J. Agustín
Suaste-Gómez, Ernesto
A Piezoelectric Plethysmograph Sensor Based on a Pt Wire Implanted Lead Lanthanum Zirconate Titanate Bulk Ceramic
title A Piezoelectric Plethysmograph Sensor Based on a Pt Wire Implanted Lead Lanthanum Zirconate Titanate Bulk Ceramic
title_full A Piezoelectric Plethysmograph Sensor Based on a Pt Wire Implanted Lead Lanthanum Zirconate Titanate Bulk Ceramic
title_fullStr A Piezoelectric Plethysmograph Sensor Based on a Pt Wire Implanted Lead Lanthanum Zirconate Titanate Bulk Ceramic
title_full_unstemmed A Piezoelectric Plethysmograph Sensor Based on a Pt Wire Implanted Lead Lanthanum Zirconate Titanate Bulk Ceramic
title_short A Piezoelectric Plethysmograph Sensor Based on a Pt Wire Implanted Lead Lanthanum Zirconate Titanate Bulk Ceramic
title_sort piezoelectric plethysmograph sensor based on a pt wire implanted lead lanthanum zirconate titanate bulk ceramic
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231161/
https://www.ncbi.nlm.nih.gov/pubmed/22163596
http://dx.doi.org/10.3390/s100807146
work_keys_str_mv AT gonzalezmorancarloso apiezoelectricplethysmographsensorbasedonaptwireimplantedleadlanthanumzirconatetitanatebulkceramic
AT florescuautlejjagustin apiezoelectricplethysmographsensorbasedonaptwireimplantedleadlanthanumzirconatetitanatebulkceramic
AT suastegomezernesto apiezoelectricplethysmographsensorbasedonaptwireimplantedleadlanthanumzirconatetitanatebulkceramic
AT gonzalezmorancarloso piezoelectricplethysmographsensorbasedonaptwireimplantedleadlanthanumzirconatetitanatebulkceramic
AT florescuautlejjagustin piezoelectricplethysmographsensorbasedonaptwireimplantedleadlanthanumzirconatetitanatebulkceramic
AT suastegomezernesto piezoelectricplethysmographsensorbasedonaptwireimplantedleadlanthanumzirconatetitanatebulkceramic