Cargando…
Micro Cantilever Movement Detection with an Amorphous Silicon Array of Position Sensitive Detectors
The movement of a micro cantilever was detected via a self constructed portable data acquisition prototype system which integrates a linear array of 32 1D amorphous silicon position sensitive detectors (PSD). The system was mounted on a microscope using a metal structure platform and the movement of...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231201/ https://www.ncbi.nlm.nih.gov/pubmed/22163648 http://dx.doi.org/10.3390/s100908173 |
_version_ | 1782218166772957184 |
---|---|
author | Contreras, Javier Costa, Daniel Pereira, Sonia Fortunato, Elvira Martins, Rodrigo Wierzbicki, Rafal Heerlein, Holger Ferreira, Isabel |
author_facet | Contreras, Javier Costa, Daniel Pereira, Sonia Fortunato, Elvira Martins, Rodrigo Wierzbicki, Rafal Heerlein, Holger Ferreira, Isabel |
author_sort | Contreras, Javier |
collection | PubMed |
description | The movement of a micro cantilever was detected via a self constructed portable data acquisition prototype system which integrates a linear array of 32 1D amorphous silicon position sensitive detectors (PSD). The system was mounted on a microscope using a metal structure platform and the movement of the 30 μm wide by 400 μm long cantilever was tracked by analyzing the signals acquired by the 32 sensor array electronic readout system and the relevant data algorithm. The obtained results show a linear behavior of the photocurrent relating X and Y movement, with a non-linearity of about 3%, a spatial resolution of less than 2 μm along the lateral dimension of the sensor as well as of less than 3 μm along the perpendicular dimension of the sensor, when detecting just the micro-cantilever, and a spatial resolution of less than 1 μm when detecting the holding structure. |
format | Online Article Text |
id | pubmed-3231201 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-32312012011-12-07 Micro Cantilever Movement Detection with an Amorphous Silicon Array of Position Sensitive Detectors Contreras, Javier Costa, Daniel Pereira, Sonia Fortunato, Elvira Martins, Rodrigo Wierzbicki, Rafal Heerlein, Holger Ferreira, Isabel Sensors (Basel) Article The movement of a micro cantilever was detected via a self constructed portable data acquisition prototype system which integrates a linear array of 32 1D amorphous silicon position sensitive detectors (PSD). The system was mounted on a microscope using a metal structure platform and the movement of the 30 μm wide by 400 μm long cantilever was tracked by analyzing the signals acquired by the 32 sensor array electronic readout system and the relevant data algorithm. The obtained results show a linear behavior of the photocurrent relating X and Y movement, with a non-linearity of about 3%, a spatial resolution of less than 2 μm along the lateral dimension of the sensor as well as of less than 3 μm along the perpendicular dimension of the sensor, when detecting just the micro-cantilever, and a spatial resolution of less than 1 μm when detecting the holding structure. Molecular Diversity Preservation International (MDPI) 2010-09-01 /pmc/articles/PMC3231201/ /pubmed/22163648 http://dx.doi.org/10.3390/s100908173 Text en © 2010 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Contreras, Javier Costa, Daniel Pereira, Sonia Fortunato, Elvira Martins, Rodrigo Wierzbicki, Rafal Heerlein, Holger Ferreira, Isabel Micro Cantilever Movement Detection with an Amorphous Silicon Array of Position Sensitive Detectors |
title | Micro Cantilever Movement Detection with an Amorphous Silicon Array of Position Sensitive Detectors |
title_full | Micro Cantilever Movement Detection with an Amorphous Silicon Array of Position Sensitive Detectors |
title_fullStr | Micro Cantilever Movement Detection with an Amorphous Silicon Array of Position Sensitive Detectors |
title_full_unstemmed | Micro Cantilever Movement Detection with an Amorphous Silicon Array of Position Sensitive Detectors |
title_short | Micro Cantilever Movement Detection with an Amorphous Silicon Array of Position Sensitive Detectors |
title_sort | micro cantilever movement detection with an amorphous silicon array of position sensitive detectors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231201/ https://www.ncbi.nlm.nih.gov/pubmed/22163648 http://dx.doi.org/10.3390/s100908173 |
work_keys_str_mv | AT contrerasjavier microcantilevermovementdetectionwithanamorphoussiliconarrayofpositionsensitivedetectors AT costadaniel microcantilevermovementdetectionwithanamorphoussiliconarrayofpositionsensitivedetectors AT pereirasonia microcantilevermovementdetectionwithanamorphoussiliconarrayofpositionsensitivedetectors AT fortunatoelvira microcantilevermovementdetectionwithanamorphoussiliconarrayofpositionsensitivedetectors AT martinsrodrigo microcantilevermovementdetectionwithanamorphoussiliconarrayofpositionsensitivedetectors AT wierzbickirafal microcantilevermovementdetectionwithanamorphoussiliconarrayofpositionsensitivedetectors AT heerleinholger microcantilevermovementdetectionwithanamorphoussiliconarrayofpositionsensitivedetectors AT ferreiraisabel microcantilevermovementdetectionwithanamorphoussiliconarrayofpositionsensitivedetectors |