Performance Evaluation of a Biometric System Based on Acoustic Images

An acoustic electronic scanning array for acquiring images from a person using a biometric application is developed. Based on pulse-echo techniques, multifrequency acoustic images are obtained for a set of positions of a person (front, front with arms outstretched, back and side). Two Uniform Linear...

Descripción completa

Detalles Bibliográficos
Autores principales: Izquierdo-Fuente, Alberto, del Val, Lara, Jiménez, María I., Villacorta, Juan J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231278/
https://www.ncbi.nlm.nih.gov/pubmed/22163708
http://dx.doi.org/10.3390/s111009499
_version_ 1782218184881864704
author Izquierdo-Fuente, Alberto
del Val, Lara
Jiménez, María I.
Villacorta, Juan J.
author_facet Izquierdo-Fuente, Alberto
del Val, Lara
Jiménez, María I.
Villacorta, Juan J.
author_sort Izquierdo-Fuente, Alberto
collection PubMed
description An acoustic electronic scanning array for acquiring images from a person using a biometric application is developed. Based on pulse-echo techniques, multifrequency acoustic images are obtained for a set of positions of a person (front, front with arms outstretched, back and side). Two Uniform Linear Arrays (ULA) with 15 λ/2-equispaced sensors have been employed, using different spatial apertures in order to reduce sidelobe levels. Working frequencies have been designed on the basis of the main lobe width, the grating lobe levels and the frequency responses of people and sensors. For a case-study with 10 people, the acoustic profiles, formed by all images acquired, are evaluated and compared in a mean square error sense. Finally, system performance, using False Match Rate (FMR)/False Non-Match Rate (FNMR) parameters and the Receiver Operating Characteristic (ROC) curve, is evaluated. On the basis of the obtained results, this system could be used for biometric applications.
format Online
Article
Text
id pubmed-3231278
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32312782011-12-07 Performance Evaluation of a Biometric System Based on Acoustic Images Izquierdo-Fuente, Alberto del Val, Lara Jiménez, María I. Villacorta, Juan J. Sensors (Basel) Article An acoustic electronic scanning array for acquiring images from a person using a biometric application is developed. Based on pulse-echo techniques, multifrequency acoustic images are obtained for a set of positions of a person (front, front with arms outstretched, back and side). Two Uniform Linear Arrays (ULA) with 15 λ/2-equispaced sensors have been employed, using different spatial apertures in order to reduce sidelobe levels. Working frequencies have been designed on the basis of the main lobe width, the grating lobe levels and the frequency responses of people and sensors. For a case-study with 10 people, the acoustic profiles, formed by all images acquired, are evaluated and compared in a mean square error sense. Finally, system performance, using False Match Rate (FMR)/False Non-Match Rate (FNMR) parameters and the Receiver Operating Characteristic (ROC) curve, is evaluated. On the basis of the obtained results, this system could be used for biometric applications. Molecular Diversity Preservation International (MDPI) 2011-10-10 /pmc/articles/PMC3231278/ /pubmed/22163708 http://dx.doi.org/10.3390/s111009499 Text en © 2011 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Izquierdo-Fuente, Alberto
del Val, Lara
Jiménez, María I.
Villacorta, Juan J.
Performance Evaluation of a Biometric System Based on Acoustic Images
title Performance Evaluation of a Biometric System Based on Acoustic Images
title_full Performance Evaluation of a Biometric System Based on Acoustic Images
title_fullStr Performance Evaluation of a Biometric System Based on Acoustic Images
title_full_unstemmed Performance Evaluation of a Biometric System Based on Acoustic Images
title_short Performance Evaluation of a Biometric System Based on Acoustic Images
title_sort performance evaluation of a biometric system based on acoustic images
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231278/
https://www.ncbi.nlm.nih.gov/pubmed/22163708
http://dx.doi.org/10.3390/s111009499
work_keys_str_mv AT izquierdofuentealberto performanceevaluationofabiometricsystembasedonacousticimages
AT delvallara performanceevaluationofabiometricsystembasedonacousticimages
AT jimenezmariai performanceevaluationofabiometricsystembasedonacousticimages
AT villacortajuanj performanceevaluationofabiometricsystembasedonacousticimages