Cargando…

Commercialisation of CMOS Integrated Circuit Technology in Multi-Electrode Arrays for Neuroscience and Cell-Based Biosensors

The adaptation of standard integrated circuit (IC) technology as a transducer in cell-based biosensors in drug discovery pharmacology, neural interface systems and electrophysiology requires electrodes that are electrochemically stable, biocompatible and affordable. Unfortunately, the ubiquitous Com...

Descripción completa

Detalles Bibliográficos
Autores principales: Graham, Anthony H. D., Robbins, Jon, Bowen, Chris R., Taylor, John
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231360/
https://www.ncbi.nlm.nih.gov/pubmed/22163884
http://dx.doi.org/10.3390/s110504943
_version_ 1782218204372795392
author Graham, Anthony H. D.
Robbins, Jon
Bowen, Chris R.
Taylor, John
author_facet Graham, Anthony H. D.
Robbins, Jon
Bowen, Chris R.
Taylor, John
author_sort Graham, Anthony H. D.
collection PubMed
description The adaptation of standard integrated circuit (IC) technology as a transducer in cell-based biosensors in drug discovery pharmacology, neural interface systems and electrophysiology requires electrodes that are electrochemically stable, biocompatible and affordable. Unfortunately, the ubiquitous Complementary Metal Oxide Semiconductor (CMOS) IC technology does not meet the first of these requirements. For devices intended only for research, modification of CMOS by post-processing using cleanroom facilities has been achieved. However, to enable adoption of CMOS as a basis for commercial biosensors, the economies of scale of CMOS fabrication must be maintained by using only low-cost post-processing techniques. This review highlights the methodologies employed in cell-based biosensor design where CMOS-based integrated circuits (ICs) form an integral part of the transducer system. Particular emphasis will be placed on the application of multi-electrode arrays for in vitro neuroscience applications. Identifying suitable IC packaging methods presents further significant challenges when considering specific applications. The various challenges and difficulties are reviewed and some potential solutions are presented.
format Online
Article
Text
id pubmed-3231360
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32313602011-12-07 Commercialisation of CMOS Integrated Circuit Technology in Multi-Electrode Arrays for Neuroscience and Cell-Based Biosensors Graham, Anthony H. D. Robbins, Jon Bowen, Chris R. Taylor, John Sensors (Basel) Review The adaptation of standard integrated circuit (IC) technology as a transducer in cell-based biosensors in drug discovery pharmacology, neural interface systems and electrophysiology requires electrodes that are electrochemically stable, biocompatible and affordable. Unfortunately, the ubiquitous Complementary Metal Oxide Semiconductor (CMOS) IC technology does not meet the first of these requirements. For devices intended only for research, modification of CMOS by post-processing using cleanroom facilities has been achieved. However, to enable adoption of CMOS as a basis for commercial biosensors, the economies of scale of CMOS fabrication must be maintained by using only low-cost post-processing techniques. This review highlights the methodologies employed in cell-based biosensor design where CMOS-based integrated circuits (ICs) form an integral part of the transducer system. Particular emphasis will be placed on the application of multi-electrode arrays for in vitro neuroscience applications. Identifying suitable IC packaging methods presents further significant challenges when considering specific applications. The various challenges and difficulties are reviewed and some potential solutions are presented. Molecular Diversity Preservation International (MDPI) 2011-05-04 /pmc/articles/PMC3231360/ /pubmed/22163884 http://dx.doi.org/10.3390/s110504943 Text en © 2011 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Review
Graham, Anthony H. D.
Robbins, Jon
Bowen, Chris R.
Taylor, John
Commercialisation of CMOS Integrated Circuit Technology in Multi-Electrode Arrays for Neuroscience and Cell-Based Biosensors
title Commercialisation of CMOS Integrated Circuit Technology in Multi-Electrode Arrays for Neuroscience and Cell-Based Biosensors
title_full Commercialisation of CMOS Integrated Circuit Technology in Multi-Electrode Arrays for Neuroscience and Cell-Based Biosensors
title_fullStr Commercialisation of CMOS Integrated Circuit Technology in Multi-Electrode Arrays for Neuroscience and Cell-Based Biosensors
title_full_unstemmed Commercialisation of CMOS Integrated Circuit Technology in Multi-Electrode Arrays for Neuroscience and Cell-Based Biosensors
title_short Commercialisation of CMOS Integrated Circuit Technology in Multi-Electrode Arrays for Neuroscience and Cell-Based Biosensors
title_sort commercialisation of cmos integrated circuit technology in multi-electrode arrays for neuroscience and cell-based biosensors
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231360/
https://www.ncbi.nlm.nih.gov/pubmed/22163884
http://dx.doi.org/10.3390/s110504943
work_keys_str_mv AT grahamanthonyhd commercialisationofcmosintegratedcircuittechnologyinmultielectrodearraysforneuroscienceandcellbasedbiosensors
AT robbinsjon commercialisationofcmosintegratedcircuittechnologyinmultielectrodearraysforneuroscienceandcellbasedbiosensors
AT bowenchrisr commercialisationofcmosintegratedcircuittechnologyinmultielectrodearraysforneuroscienceandcellbasedbiosensors
AT taylorjohn commercialisationofcmosintegratedcircuittechnologyinmultielectrodearraysforneuroscienceandcellbasedbiosensors