Cargando…

Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors

In the last ten to fifteen years there has been much research in using amorphous and polycrystalline semiconductors as x-ray photoconductors in various x-ray image sensor applications, most notably in flat panel x-ray imagers (FPXIs). We first outline the essential requirements for an ideal large ar...

Descripción completa

Detalles Bibliográficos
Autores principales: Kasap, Safa, Frey, Joel B., Belev, George, Tousignant, Olivier, Mani, Habib, Greenspan, Jonathan, Laperriere, Luc, Bubon, Oleksandr, Reznik, Alla, DeCrescenzo, Giovanni, Karim, Karim S., Rowlands, John A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231396/
https://www.ncbi.nlm.nih.gov/pubmed/22163893
http://dx.doi.org/10.3390/s110505112
_version_ 1782218212355604480
author Kasap, Safa
Frey, Joel B.
Belev, George
Tousignant, Olivier
Mani, Habib
Greenspan, Jonathan
Laperriere, Luc
Bubon, Oleksandr
Reznik, Alla
DeCrescenzo, Giovanni
Karim, Karim S.
Rowlands, John A.
author_facet Kasap, Safa
Frey, Joel B.
Belev, George
Tousignant, Olivier
Mani, Habib
Greenspan, Jonathan
Laperriere, Luc
Bubon, Oleksandr
Reznik, Alla
DeCrescenzo, Giovanni
Karim, Karim S.
Rowlands, John A.
author_sort Kasap, Safa
collection PubMed
description In the last ten to fifteen years there has been much research in using amorphous and polycrystalline semiconductors as x-ray photoconductors in various x-ray image sensor applications, most notably in flat panel x-ray imagers (FPXIs). We first outline the essential requirements for an ideal large area photoconductor for use in a FPXI, and discuss how some of the current amorphous and polycrystalline semiconductors fulfill these requirements. At present, only stabilized amorphous selenium (doped and alloyed a-Se) has been commercialized, and FPXIs based on a-Se are particularly suitable for mammography, operating at the ideal limit of high detective quantum efficiency (DQE). Further, these FPXIs can also be used in real-time, and have already been used in such applications as tomosynthesis. We discuss some of the important attributes of amorphous and polycrystalline x-ray photoconductors such as their large area deposition ability, charge collection efficiency, x-ray sensitivity, DQE, modulation transfer function (MTF) and the importance of the dark current. We show the importance of charge trapping in limiting not only the sensitivity but also the resolution of these detectors. Limitations on the maximum acceptable dark current and the corresponding charge collection efficiency jointly impose a practical constraint that many photoconductors fail to satisfy. We discuss the case of a-Se in which the dark current was brought down by three orders of magnitude by the use of special blocking layers to satisfy the dark current constraint. There are also a number of polycrystalline photoconductors, HgI(2) and PbO being good examples, that show potential for commercialization in the same way that multilayer stabilized a-Se x-ray photoconductors were developed for commercial applications. We highlight the unique nature of avalanche multiplication in a-Se and how it has led to the development of the commercial HARP video-tube. An all solid state version of the HARP has been recently demonstrated with excellent avalanche gains; the latter is expected to lead to a number of novel imaging device applications that would be quantum noise limited. While passive pixel sensors use one TFT (thin film transistor) as a switch at the pixel, active pixel sensors (APSs) have two or more transistors and provide gain at the pixel level. The advantages of APS based x-ray imagers are also discussed with examples.
format Online
Article
Text
id pubmed-3231396
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32313962011-12-07 Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors Kasap, Safa Frey, Joel B. Belev, George Tousignant, Olivier Mani, Habib Greenspan, Jonathan Laperriere, Luc Bubon, Oleksandr Reznik, Alla DeCrescenzo, Giovanni Karim, Karim S. Rowlands, John A. Sensors (Basel) Review In the last ten to fifteen years there has been much research in using amorphous and polycrystalline semiconductors as x-ray photoconductors in various x-ray image sensor applications, most notably in flat panel x-ray imagers (FPXIs). We first outline the essential requirements for an ideal large area photoconductor for use in a FPXI, and discuss how some of the current amorphous and polycrystalline semiconductors fulfill these requirements. At present, only stabilized amorphous selenium (doped and alloyed a-Se) has been commercialized, and FPXIs based on a-Se are particularly suitable for mammography, operating at the ideal limit of high detective quantum efficiency (DQE). Further, these FPXIs can also be used in real-time, and have already been used in such applications as tomosynthesis. We discuss some of the important attributes of amorphous and polycrystalline x-ray photoconductors such as their large area deposition ability, charge collection efficiency, x-ray sensitivity, DQE, modulation transfer function (MTF) and the importance of the dark current. We show the importance of charge trapping in limiting not only the sensitivity but also the resolution of these detectors. Limitations on the maximum acceptable dark current and the corresponding charge collection efficiency jointly impose a practical constraint that many photoconductors fail to satisfy. We discuss the case of a-Se in which the dark current was brought down by three orders of magnitude by the use of special blocking layers to satisfy the dark current constraint. There are also a number of polycrystalline photoconductors, HgI(2) and PbO being good examples, that show potential for commercialization in the same way that multilayer stabilized a-Se x-ray photoconductors were developed for commercial applications. We highlight the unique nature of avalanche multiplication in a-Se and how it has led to the development of the commercial HARP video-tube. An all solid state version of the HARP has been recently demonstrated with excellent avalanche gains; the latter is expected to lead to a number of novel imaging device applications that would be quantum noise limited. While passive pixel sensors use one TFT (thin film transistor) as a switch at the pixel, active pixel sensors (APSs) have two or more transistors and provide gain at the pixel level. The advantages of APS based x-ray imagers are also discussed with examples. Molecular Diversity Preservation International (MDPI) 2011-05-09 /pmc/articles/PMC3231396/ /pubmed/22163893 http://dx.doi.org/10.3390/s110505112 Text en © 2011 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Review
Kasap, Safa
Frey, Joel B.
Belev, George
Tousignant, Olivier
Mani, Habib
Greenspan, Jonathan
Laperriere, Luc
Bubon, Oleksandr
Reznik, Alla
DeCrescenzo, Giovanni
Karim, Karim S.
Rowlands, John A.
Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors
title Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors
title_full Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors
title_fullStr Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors
title_full_unstemmed Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors
title_short Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors
title_sort amorphous and polycrystalline photoconductors for direct conversion flat panel x-ray image sensors
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231396/
https://www.ncbi.nlm.nih.gov/pubmed/22163893
http://dx.doi.org/10.3390/s110505112
work_keys_str_mv AT kasapsafa amorphousandpolycrystallinephotoconductorsfordirectconversionflatpanelxrayimagesensors
AT freyjoelb amorphousandpolycrystallinephotoconductorsfordirectconversionflatpanelxrayimagesensors
AT belevgeorge amorphousandpolycrystallinephotoconductorsfordirectconversionflatpanelxrayimagesensors
AT tousignantolivier amorphousandpolycrystallinephotoconductorsfordirectconversionflatpanelxrayimagesensors
AT manihabib amorphousandpolycrystallinephotoconductorsfordirectconversionflatpanelxrayimagesensors
AT greenspanjonathan amorphousandpolycrystallinephotoconductorsfordirectconversionflatpanelxrayimagesensors
AT laperriereluc amorphousandpolycrystallinephotoconductorsfordirectconversionflatpanelxrayimagesensors
AT bubonoleksandr amorphousandpolycrystallinephotoconductorsfordirectconversionflatpanelxrayimagesensors
AT reznikalla amorphousandpolycrystallinephotoconductorsfordirectconversionflatpanelxrayimagesensors
AT decrescenzogiovanni amorphousandpolycrystallinephotoconductorsfordirectconversionflatpanelxrayimagesensors
AT karimkarims amorphousandpolycrystallinephotoconductorsfordirectconversionflatpanelxrayimagesensors
AT rowlandsjohna amorphousandpolycrystallinephotoconductorsfordirectconversionflatpanelxrayimagesensors