Cargando…

Development of an Integrated Microfluidic Perfusion Cell Culture System for Real-Time Microscopic Observation of Biological Cells

This study reports an integrated microfluidic perfusion cell culture system consisting of a microfluidic cell culture chip, and an indium tin oxide (ITO) glass-based microheater chip for micro-scale perfusion cell culture, and its real-time microscopic observation. The system features in maintaining...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Lung, Wang, Shih-Siou, Wu, Min-Hsien, Oh-Yang, Chih-Chin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231477/
https://www.ncbi.nlm.nih.gov/pubmed/22164082
http://dx.doi.org/10.3390/s110908395
_version_ 1782218230953148416
author Lin, Lung
Wang, Shih-Siou
Wu, Min-Hsien
Oh-Yang, Chih-Chin
author_facet Lin, Lung
Wang, Shih-Siou
Wu, Min-Hsien
Oh-Yang, Chih-Chin
author_sort Lin, Lung
collection PubMed
description This study reports an integrated microfluidic perfusion cell culture system consisting of a microfluidic cell culture chip, and an indium tin oxide (ITO) glass-based microheater chip for micro-scale perfusion cell culture, and its real-time microscopic observation. The system features in maintaining both uniform, and stable chemical or thermal environments, and providing a backflow-free medium pumping, and a precise thermal control functions. In this work, the performance of the medium pumping scheme, and the ITO glass microheater were experimentally evaluated. Results show that the medium delivery mechanism was able to provide pumping rates ranging from 15.4 to 120.0 μL·min(−1). In addition, numerical simulation and experimental evaluation were conducted to verify that the ITO glass microheater was capable of providing a spatially uniform thermal environment, and precise temperature control with a mild variation of ±0.3 °C. Furthermore, a perfusion cell culture was successfully demonstrated, showing the cultured cells were kept at high cell viability of 95 ± 2%. In the process, the cultured chondrocytes can be clearly visualized microscopically. As a whole, the proposed cell culture system has paved an alternative route to carry out real-time microscopic observation of biological cells in a simple, user-friendly, and low cost manner.
format Online
Article
Text
id pubmed-3231477
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32314772011-12-07 Development of an Integrated Microfluidic Perfusion Cell Culture System for Real-Time Microscopic Observation of Biological Cells Lin, Lung Wang, Shih-Siou Wu, Min-Hsien Oh-Yang, Chih-Chin Sensors (Basel) Article This study reports an integrated microfluidic perfusion cell culture system consisting of a microfluidic cell culture chip, and an indium tin oxide (ITO) glass-based microheater chip for micro-scale perfusion cell culture, and its real-time microscopic observation. The system features in maintaining both uniform, and stable chemical or thermal environments, and providing a backflow-free medium pumping, and a precise thermal control functions. In this work, the performance of the medium pumping scheme, and the ITO glass microheater were experimentally evaluated. Results show that the medium delivery mechanism was able to provide pumping rates ranging from 15.4 to 120.0 μL·min(−1). In addition, numerical simulation and experimental evaluation were conducted to verify that the ITO glass microheater was capable of providing a spatially uniform thermal environment, and precise temperature control with a mild variation of ±0.3 °C. Furthermore, a perfusion cell culture was successfully demonstrated, showing the cultured cells were kept at high cell viability of 95 ± 2%. In the process, the cultured chondrocytes can be clearly visualized microscopically. As a whole, the proposed cell culture system has paved an alternative route to carry out real-time microscopic observation of biological cells in a simple, user-friendly, and low cost manner. Molecular Diversity Preservation International (MDPI) 2011-08-29 /pmc/articles/PMC3231477/ /pubmed/22164082 http://dx.doi.org/10.3390/s110908395 Text en © 2011 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Lin, Lung
Wang, Shih-Siou
Wu, Min-Hsien
Oh-Yang, Chih-Chin
Development of an Integrated Microfluidic Perfusion Cell Culture System for Real-Time Microscopic Observation of Biological Cells
title Development of an Integrated Microfluidic Perfusion Cell Culture System for Real-Time Microscopic Observation of Biological Cells
title_full Development of an Integrated Microfluidic Perfusion Cell Culture System for Real-Time Microscopic Observation of Biological Cells
title_fullStr Development of an Integrated Microfluidic Perfusion Cell Culture System for Real-Time Microscopic Observation of Biological Cells
title_full_unstemmed Development of an Integrated Microfluidic Perfusion Cell Culture System for Real-Time Microscopic Observation of Biological Cells
title_short Development of an Integrated Microfluidic Perfusion Cell Culture System for Real-Time Microscopic Observation of Biological Cells
title_sort development of an integrated microfluidic perfusion cell culture system for real-time microscopic observation of biological cells
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231477/
https://www.ncbi.nlm.nih.gov/pubmed/22164082
http://dx.doi.org/10.3390/s110908395
work_keys_str_mv AT linlung developmentofanintegratedmicrofluidicperfusioncellculturesystemforrealtimemicroscopicobservationofbiologicalcells
AT wangshihsiou developmentofanintegratedmicrofluidicperfusioncellculturesystemforrealtimemicroscopicobservationofbiologicalcells
AT wuminhsien developmentofanintegratedmicrofluidicperfusioncellculturesystemforrealtimemicroscopicobservationofbiologicalcells
AT ohyangchihchin developmentofanintegratedmicrofluidicperfusioncellculturesystemforrealtimemicroscopicobservationofbiologicalcells