Cargando…

A Microfluidic Long-Period Fiber Grating Sensor Platform for Chloride Ion Concentration Measurement

Optical fiber sensors based on waveguide technology are promising and attractive in chemical, biotechnological, agronomy, and civil engineering applications. A microfluidic system equipped with a long-period fiber grating (LPFG) capable of measuring chloride ion concentrations of several sample mate...

Descripción completa

Detalles Bibliográficos
Autor principal: Wang, Jian-Neng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231478/
https://www.ncbi.nlm.nih.gov/pubmed/22164091
http://dx.doi.org/10.3390/s110908550
_version_ 1782218231178592256
author Wang, Jian-Neng
author_facet Wang, Jian-Neng
author_sort Wang, Jian-Neng
collection PubMed
description Optical fiber sensors based on waveguide technology are promising and attractive in chemical, biotechnological, agronomy, and civil engineering applications. A microfluidic system equipped with a long-period fiber grating (LPFG) capable of measuring chloride ion concentrations of several sample materials is presented. The LPFG-based microfluidic platform was shown to be effective in sensing very small quantities of samples and its transmitted light signal could easily be used as a measurand. The investigated sample materials included reverse osmosis (RO) water, tap water, dilute aqueous sample of sea sand soaked in RO water, aqueous sample of sea sand soaked in RO water, dilute seawater, and seawater. By employing additionally a chloride ion-selective electrode sensor for the calibration of chloride-ion concentration, a useful correlation (R(2) = 0.975) was found between the separately-measured chloride concentration and the light intensity transmitted through the LPFG at a wavelength of 1,550 nm. Experimental results show that the sensitivity of the LPFG sensor by light intensity interrogation was determined to be 5.0 × 10(−6) mW/mg/L for chloride ion concentrations below 2,400 mg/L. The results obtained from the analysis of data variations in time-series measurements for all sample materials show that standard deviations of output power were relatively small and found in the range of 7.413 × 10(−5)−2.769 × 10(−3) mW. In addition, a fairly small coefficients of variations were also obtained, which were in the range of 0.03%–1.29% and decreased with the decrease of chloride ion concentrations of sample materials. Moreover, the analysis of stability performance of the LPFG sensor indicated that the random walk coefficient decreased with the increase of the chloride ion concentration, illustrating that measurement stability using the microfluidic platform was capable of measuring transmitted optical power with accuracy in the range of −0.8569 mW/ [Formula: see text] to −0.5169 mW/ [Formula: see text]. Furthermore, the bias stability was determined to be in the range of less than 6.134 × 10(−8) mW/h with 600 s time cluster to less than 1.412 × 10(−6) mW/h with 600 s time cluster. Thus, the proposed LPFG-based microfluidic platform has the potential for civil, chemical, biological, and biochemical sensing with aqueous solutions. The compact (3.5 × 4.2 cm), low-cost, real-time, small-volume (∼70 μL), low-noise, and high-sensitive chloride ion sensing system reported here could hopefully benefit the development and applications in the field of chemical, biotechnical, soil and geotechnical, and civil engineering.
format Online
Article
Text
id pubmed-3231478
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32314782011-12-07 A Microfluidic Long-Period Fiber Grating Sensor Platform for Chloride Ion Concentration Measurement Wang, Jian-Neng Sensors (Basel) Article Optical fiber sensors based on waveguide technology are promising and attractive in chemical, biotechnological, agronomy, and civil engineering applications. A microfluidic system equipped with a long-period fiber grating (LPFG) capable of measuring chloride ion concentrations of several sample materials is presented. The LPFG-based microfluidic platform was shown to be effective in sensing very small quantities of samples and its transmitted light signal could easily be used as a measurand. The investigated sample materials included reverse osmosis (RO) water, tap water, dilute aqueous sample of sea sand soaked in RO water, aqueous sample of sea sand soaked in RO water, dilute seawater, and seawater. By employing additionally a chloride ion-selective electrode sensor for the calibration of chloride-ion concentration, a useful correlation (R(2) = 0.975) was found between the separately-measured chloride concentration and the light intensity transmitted through the LPFG at a wavelength of 1,550 nm. Experimental results show that the sensitivity of the LPFG sensor by light intensity interrogation was determined to be 5.0 × 10(−6) mW/mg/L for chloride ion concentrations below 2,400 mg/L. The results obtained from the analysis of data variations in time-series measurements for all sample materials show that standard deviations of output power were relatively small and found in the range of 7.413 × 10(−5)−2.769 × 10(−3) mW. In addition, a fairly small coefficients of variations were also obtained, which were in the range of 0.03%–1.29% and decreased with the decrease of chloride ion concentrations of sample materials. Moreover, the analysis of stability performance of the LPFG sensor indicated that the random walk coefficient decreased with the increase of the chloride ion concentration, illustrating that measurement stability using the microfluidic platform was capable of measuring transmitted optical power with accuracy in the range of −0.8569 mW/ [Formula: see text] to −0.5169 mW/ [Formula: see text]. Furthermore, the bias stability was determined to be in the range of less than 6.134 × 10(−8) mW/h with 600 s time cluster to less than 1.412 × 10(−6) mW/h with 600 s time cluster. Thus, the proposed LPFG-based microfluidic platform has the potential for civil, chemical, biological, and biochemical sensing with aqueous solutions. The compact (3.5 × 4.2 cm), low-cost, real-time, small-volume (∼70 μL), low-noise, and high-sensitive chloride ion sensing system reported here could hopefully benefit the development and applications in the field of chemical, biotechnical, soil and geotechnical, and civil engineering. Molecular Diversity Preservation International (MDPI) 2011-09-02 /pmc/articles/PMC3231478/ /pubmed/22164091 http://dx.doi.org/10.3390/s110908550 Text en © 2011 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Wang, Jian-Neng
A Microfluidic Long-Period Fiber Grating Sensor Platform for Chloride Ion Concentration Measurement
title A Microfluidic Long-Period Fiber Grating Sensor Platform for Chloride Ion Concentration Measurement
title_full A Microfluidic Long-Period Fiber Grating Sensor Platform for Chloride Ion Concentration Measurement
title_fullStr A Microfluidic Long-Period Fiber Grating Sensor Platform for Chloride Ion Concentration Measurement
title_full_unstemmed A Microfluidic Long-Period Fiber Grating Sensor Platform for Chloride Ion Concentration Measurement
title_short A Microfluidic Long-Period Fiber Grating Sensor Platform for Chloride Ion Concentration Measurement
title_sort microfluidic long-period fiber grating sensor platform for chloride ion concentration measurement
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231478/
https://www.ncbi.nlm.nih.gov/pubmed/22164091
http://dx.doi.org/10.3390/s110908550
work_keys_str_mv AT wangjianneng amicrofluidiclongperiodfibergratingsensorplatformforchlorideionconcentrationmeasurement
AT wangjianneng microfluidiclongperiodfibergratingsensorplatformforchlorideionconcentrationmeasurement