This report investigates the sensing characteristics of polysilicon wire (PSW) glucose biosensors, including thickness characteristics and line-width effects on detection limits, linear range and interference immunity with membranes coated by micropipette/spin-coating and focus-ion-beam (FIB) proces...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231599/ https://www.ncbi.nlm.nih.gov/pubmed/22163767 http://dx.doi.org/10.3390/s110302796 |
_version_ | 1782218244314103808 |
---|---|
author | Lin, Jing-Jenn Hsu, Po-Yen Wu, You-Lin Jhuang, Jheng-Jia |
author_facet | Lin, Jing-Jenn Hsu, Po-Yen Wu, You-Lin Jhuang, Jheng-Jia |
author_sort | Lin, Jing-Jenn |
collection | PubMed |
description | This report investigates the sensing characteristics of polysilicon wire (PSW) glucose biosensors, including thickness characteristics and line-width effects on detection limits, linear range and interference immunity with membranes coated by micropipette/spin-coating and focus-ion-beam (FIB) processed capillary atomic-force-microscopy (C-AFM) tip scan/coating methods. The PSW surface was modified with a mixture of 3-aminopropyl-triethoxysilane (γ-APTES) and polydimethylsiloxane (PDMS)-treated hydrophobic fumed silica nanoparticles (NPs). We found that the thickness of the γ-APTES+NPs nonocomposite could be controlled well at about 22 nm with small relative standard deviation (RSD) with repeated C-AFM tip scan/coatings. The detection limit increased and linear range decreased with the line width of the PSW through the tip-coating process. Interestingly, the interference immunity ability improves as the line width increases. For a 500 nm-wide PSW, the percentage changes of the channel current density changes (ΔJ) caused by acetaminophen (AP) can be kept below 3.5% at an ultra-high AP-to-glucose concentration ratio of 600:1. Simulation results showed that the line width dependence of interference immunity was strongly correlated with the channel electrical field of the PSW biosensor. |
format | Online Article Text |
id | pubmed-3231599 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-32315992011-12-07 Characteristics of Polysilicon Wire Glucose Sensors with a Surface Modified by Silica Nanoparticles/γ-APTES Nanocomposite Lin, Jing-Jenn Hsu, Po-Yen Wu, You-Lin Jhuang, Jheng-Jia Sensors (Basel) Article This report investigates the sensing characteristics of polysilicon wire (PSW) glucose biosensors, including thickness characteristics and line-width effects on detection limits, linear range and interference immunity with membranes coated by micropipette/spin-coating and focus-ion-beam (FIB) processed capillary atomic-force-microscopy (C-AFM) tip scan/coating methods. The PSW surface was modified with a mixture of 3-aminopropyl-triethoxysilane (γ-APTES) and polydimethylsiloxane (PDMS)-treated hydrophobic fumed silica nanoparticles (NPs). We found that the thickness of the γ-APTES+NPs nonocomposite could be controlled well at about 22 nm with small relative standard deviation (RSD) with repeated C-AFM tip scan/coatings. The detection limit increased and linear range decreased with the line width of the PSW through the tip-coating process. Interestingly, the interference immunity ability improves as the line width increases. For a 500 nm-wide PSW, the percentage changes of the channel current density changes (ΔJ) caused by acetaminophen (AP) can be kept below 3.5% at an ultra-high AP-to-glucose concentration ratio of 600:1. Simulation results showed that the line width dependence of interference immunity was strongly correlated with the channel electrical field of the PSW biosensor. Molecular Diversity Preservation International (MDPI) 2011-03-02 /pmc/articles/PMC3231599/ /pubmed/22163767 http://dx.doi.org/10.3390/s110302796 Text en © 2011 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Lin, Jing-Jenn Hsu, Po-Yen Wu, You-Lin Jhuang, Jheng-Jia Characteristics of Polysilicon Wire Glucose Sensors with a Surface Modified by Silica Nanoparticles/γ-APTES Nanocomposite |
title | Characteristics of Polysilicon Wire Glucose Sensors with a Surface Modified by Silica Nanoparticles/γ-APTES Nanocomposite |
title_full | Characteristics of Polysilicon Wire Glucose Sensors with a Surface Modified by Silica Nanoparticles/γ-APTES Nanocomposite |
title_fullStr | Characteristics of Polysilicon Wire Glucose Sensors with a Surface Modified by Silica Nanoparticles/γ-APTES Nanocomposite |
title_full_unstemmed | Characteristics of Polysilicon Wire Glucose Sensors with a Surface Modified by Silica Nanoparticles/γ-APTES Nanocomposite |
title_short | Characteristics of Polysilicon Wire Glucose Sensors with a Surface Modified by Silica Nanoparticles/γ-APTES Nanocomposite |
title_sort | characteristics of polysilicon wire glucose sensors with a surface modified by silica nanoparticles/γ-aptes nanocomposite |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231599/ https://www.ncbi.nlm.nih.gov/pubmed/22163767 http://dx.doi.org/10.3390/s110302796 |
work_keys_str_mv | AT linjingjenn characteristicsofpolysiliconwireglucosesensorswithasurfacemodifiedbysilicananoparticlesgaptesnanocomposite AT hsupoyen characteristicsofpolysiliconwireglucosesensorswithasurfacemodifiedbysilicananoparticlesgaptesnanocomposite AT wuyoulin characteristicsofpolysiliconwireglucosesensorswithasurfacemodifiedbysilicananoparticlesgaptesnanocomposite AT jhuangjhengjia characteristicsofpolysiliconwireglucosesensorswithasurfacemodifiedbysilicananoparticlesgaptesnanocomposite |