Cargando…

LuxCDABE—Transformed Constitutively Bioluminescent Escherichia coli for Toxicity Screening: Comparison with Naturally Luminous Vibrio fischeri

We show that in vitro toxicity assay based on inhibition of the bioluminescence of recombinant Escherichia coli encoding thermostable luciferase from Photorhabdus luminescens is a versatile alternative to Vibrio fischeri Microtox™ test. Performance of two luxCDABE-transformed E. coli MC1061 construc...

Descripción completa

Detalles Bibliográficos
Autores principales: Kurvet, Imbi, Ivask, Angela, Bondarenko, Olesja, Sihtmäe, Mariliis, Kahru, Anne
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231736/
https://www.ncbi.nlm.nih.gov/pubmed/22164050
http://dx.doi.org/10.3390/s110807865
_version_ 1782218275674914816
author Kurvet, Imbi
Ivask, Angela
Bondarenko, Olesja
Sihtmäe, Mariliis
Kahru, Anne
author_facet Kurvet, Imbi
Ivask, Angela
Bondarenko, Olesja
Sihtmäe, Mariliis
Kahru, Anne
author_sort Kurvet, Imbi
collection PubMed
description We show that in vitro toxicity assay based on inhibition of the bioluminescence of recombinant Escherichia coli encoding thermostable luciferase from Photorhabdus luminescens is a versatile alternative to Vibrio fischeri Microtox™ test. Performance of two luxCDABE-transformed E. coli MC1061 constructs (pDNlux) and (pSLlux) otherwise identical, but having 100-fold different background luminescence was compared with the performance of V. fischeri. The microplate luminometer and a kinetic Flash-Assay test format was used that differently from Microtox test is also applicable for high throughput analysis. Toxic effects (30-s till 30-min EC(50)) of four heavy metals (Zn, Cd, Hg, Cu) and three organic chemicals (aniline, 3,5-dichloroaniline and 3,5-dichlorophenol) were studied. Both E. coli strains had comparable sensitivity and the respective 30-min EC(50) values highly correlated (log-log R(2) = 0.99; p < 0.01) showing that the sensitivity of the recombinant bacteria towards chemicals analyzed did not depend on the bioluminescence level of the recombinant cells. The most toxic chemical for all used bacterial strains (E. coli, V. fischeri) was mercury whereas the lowest EC(50) values for Hg (0.04–0.05 mg/L) and highest EC(50) values for aniline (1,300–1,700 mg/L) were observed for E. coli strains. Despite of that, toxicity results obtained with both E. coli strains (pSLlux and pDNlux) significantly correlated with V. fischeri results (log-log R(2) = 0.70/0.75; p < 0.05/0.01). The use of amino acids (0.25%) and glucose (0.05%)-supplemented M9 medium instead of leucine-supplemented saline significantly (p < 0.05) reduced the apparent toxicity of heavy metals to both E. coli strains up to three orders of magnitude, but had little or no complexing effect on organic compounds. Thus, P. luminescens luxCDABE-transformed E. coli strains can be successfully used for the acute toxicity screening of various types of organic chemicals and heavy metals and can replace V. fischeri in certain cases where the thermostability of luciferase >30 °C is crucial. The kinetic Flash Assay test format of the bioluminescence inhibition assay facilitates high throughput analysis. The assay medium, especially in case of testing heavy metals should be a compromise: optimal for the viability/luminescence of the recombinant test strain and of minimum complexing potential.
format Online
Article
Text
id pubmed-3231736
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32317362011-12-07 LuxCDABE—Transformed Constitutively Bioluminescent Escherichia coli for Toxicity Screening: Comparison with Naturally Luminous Vibrio fischeri Kurvet, Imbi Ivask, Angela Bondarenko, Olesja Sihtmäe, Mariliis Kahru, Anne Sensors (Basel) Article We show that in vitro toxicity assay based on inhibition of the bioluminescence of recombinant Escherichia coli encoding thermostable luciferase from Photorhabdus luminescens is a versatile alternative to Vibrio fischeri Microtox™ test. Performance of two luxCDABE-transformed E. coli MC1061 constructs (pDNlux) and (pSLlux) otherwise identical, but having 100-fold different background luminescence was compared with the performance of V. fischeri. The microplate luminometer and a kinetic Flash-Assay test format was used that differently from Microtox test is also applicable for high throughput analysis. Toxic effects (30-s till 30-min EC(50)) of four heavy metals (Zn, Cd, Hg, Cu) and three organic chemicals (aniline, 3,5-dichloroaniline and 3,5-dichlorophenol) were studied. Both E. coli strains had comparable sensitivity and the respective 30-min EC(50) values highly correlated (log-log R(2) = 0.99; p < 0.01) showing that the sensitivity of the recombinant bacteria towards chemicals analyzed did not depend on the bioluminescence level of the recombinant cells. The most toxic chemical for all used bacterial strains (E. coli, V. fischeri) was mercury whereas the lowest EC(50) values for Hg (0.04–0.05 mg/L) and highest EC(50) values for aniline (1,300–1,700 mg/L) were observed for E. coli strains. Despite of that, toxicity results obtained with both E. coli strains (pSLlux and pDNlux) significantly correlated with V. fischeri results (log-log R(2) = 0.70/0.75; p < 0.05/0.01). The use of amino acids (0.25%) and glucose (0.05%)-supplemented M9 medium instead of leucine-supplemented saline significantly (p < 0.05) reduced the apparent toxicity of heavy metals to both E. coli strains up to three orders of magnitude, but had little or no complexing effect on organic compounds. Thus, P. luminescens luxCDABE-transformed E. coli strains can be successfully used for the acute toxicity screening of various types of organic chemicals and heavy metals and can replace V. fischeri in certain cases where the thermostability of luciferase >30 °C is crucial. The kinetic Flash Assay test format of the bioluminescence inhibition assay facilitates high throughput analysis. The assay medium, especially in case of testing heavy metals should be a compromise: optimal for the viability/luminescence of the recombinant test strain and of minimum complexing potential. Molecular Diversity Preservation International (MDPI) 2011-08-11 /pmc/articles/PMC3231736/ /pubmed/22164050 http://dx.doi.org/10.3390/s110807865 Text en © 2011 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Kurvet, Imbi
Ivask, Angela
Bondarenko, Olesja
Sihtmäe, Mariliis
Kahru, Anne
LuxCDABE—Transformed Constitutively Bioluminescent Escherichia coli for Toxicity Screening: Comparison with Naturally Luminous Vibrio fischeri
title LuxCDABE—Transformed Constitutively Bioluminescent Escherichia coli for Toxicity Screening: Comparison with Naturally Luminous Vibrio fischeri
title_full LuxCDABE—Transformed Constitutively Bioluminescent Escherichia coli for Toxicity Screening: Comparison with Naturally Luminous Vibrio fischeri
title_fullStr LuxCDABE—Transformed Constitutively Bioluminescent Escherichia coli for Toxicity Screening: Comparison with Naturally Luminous Vibrio fischeri
title_full_unstemmed LuxCDABE—Transformed Constitutively Bioluminescent Escherichia coli for Toxicity Screening: Comparison with Naturally Luminous Vibrio fischeri
title_short LuxCDABE—Transformed Constitutively Bioluminescent Escherichia coli for Toxicity Screening: Comparison with Naturally Luminous Vibrio fischeri
title_sort luxcdabe—transformed constitutively bioluminescent escherichia coli for toxicity screening: comparison with naturally luminous vibrio fischeri
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231736/
https://www.ncbi.nlm.nih.gov/pubmed/22164050
http://dx.doi.org/10.3390/s110807865
work_keys_str_mv AT kurvetimbi luxcdabetransformedconstitutivelybioluminescentescherichiacolifortoxicityscreeningcomparisonwithnaturallyluminousvibriofischeri
AT ivaskangela luxcdabetransformedconstitutivelybioluminescentescherichiacolifortoxicityscreeningcomparisonwithnaturallyluminousvibriofischeri
AT bondarenkoolesja luxcdabetransformedconstitutivelybioluminescentescherichiacolifortoxicityscreeningcomparisonwithnaturallyluminousvibriofischeri
AT sihtmaemariliis luxcdabetransformedconstitutivelybioluminescentescherichiacolifortoxicityscreeningcomparisonwithnaturallyluminousvibriofischeri
AT kahruanne luxcdabetransformedconstitutivelybioluminescentescherichiacolifortoxicityscreeningcomparisonwithnaturallyluminousvibriofischeri