The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome
Following its introduction into clinical practice, the Amplatzer duct occluder (ADO) has achieved a definite place in the armamentarium of the interventional cardiologist for the closure of moderate to large sized PDAs. The device combines ease of use, including retrievability and repositioning when...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3232577/ https://www.ncbi.nlm.nih.gov/pubmed/22368670 |
_version_ | 1782218380744327168 |
---|---|
author | Boehm, W Emmel, M Sreeram, N |
author_facet | Boehm, W Emmel, M Sreeram, N |
author_sort | Boehm, W |
collection | PubMed |
description | Following its introduction into clinical practice, the Amplatzer duct occluder (ADO) has achieved a definite place in the armamentarium of the interventional cardiologist for the closure of moderate to large sized PDAs. The device combines ease of use, including retrievability and repositioning when required, and a high occlusion rate (>99% complete occlusion of PDA within 6 months of implant, with the majority of occlusions occurring within 24 hours of implant). Possible complications, such as device embolization, protrusion of the retention disc of the device into the aorta producing aortic obstruction, or obstruction of a branch pulmonary artery by the device are also uncommon and can be avoided by choosing the appropriate sized device (with the pulmonary end of the device being 2mm larger in diameter than the minimum measured ductal diameter), and paying scrupulous attention to technique of deployment. The device can be safely deployed in infants >3.5 kg, and can currently close PDAs of upto 11 to 12mm in minimum diameter. A brief description of the device, the technique of implantation, and the clinical results to date are provided. |
format | Online Article Text |
id | pubmed-3232577 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2007 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-32325772012-02-22 The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome Boehm, W Emmel, M Sreeram, N Images Paediatr Cardiol Original Article Following its introduction into clinical practice, the Amplatzer duct occluder (ADO) has achieved a definite place in the armamentarium of the interventional cardiologist for the closure of moderate to large sized PDAs. The device combines ease of use, including retrievability and repositioning when required, and a high occlusion rate (>99% complete occlusion of PDA within 6 months of implant, with the majority of occlusions occurring within 24 hours of implant). Possible complications, such as device embolization, protrusion of the retention disc of the device into the aorta producing aortic obstruction, or obstruction of a branch pulmonary artery by the device are also uncommon and can be avoided by choosing the appropriate sized device (with the pulmonary end of the device being 2mm larger in diameter than the minimum measured ductal diameter), and paying scrupulous attention to technique of deployment. The device can be safely deployed in infants >3.5 kg, and can currently close PDAs of upto 11 to 12mm in minimum diameter. A brief description of the device, the technique of implantation, and the clinical results to date are provided. Medknow Publications & Media Pvt Ltd 2007 /pmc/articles/PMC3232577/ /pubmed/22368670 Text en Copyright: © Images in Paediatric Cardiology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Boehm, W Emmel, M Sreeram, N The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome |
title | The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome |
title_full | The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome |
title_fullStr | The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome |
title_full_unstemmed | The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome |
title_short | The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome |
title_sort | amplatzer duct occluder for pda closure: indications, technique of implantation and clinical outcome |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3232577/ https://www.ncbi.nlm.nih.gov/pubmed/22368670 |
work_keys_str_mv | AT boehmw theamplatzerductoccluderforpdaclosureindicationstechniqueofimplantationandclinicaloutcome AT emmelm theamplatzerductoccluderforpdaclosureindicationstechniqueofimplantationandclinicaloutcome AT sreeramn theamplatzerductoccluderforpdaclosureindicationstechniqueofimplantationandclinicaloutcome AT boehmw amplatzerductoccluderforpdaclosureindicationstechniqueofimplantationandclinicaloutcome AT emmelm amplatzerductoccluderforpdaclosureindicationstechniqueofimplantationandclinicaloutcome AT sreeramn amplatzerductoccluderforpdaclosureindicationstechniqueofimplantationandclinicaloutcome |