Cargando…

The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome

Following its introduction into clinical practice, the Amplatzer duct occluder (ADO) has achieved a definite place in the armamentarium of the interventional cardiologist for the closure of moderate to large sized PDAs. The device combines ease of use, including retrievability and repositioning when...

Descripción completa

Detalles Bibliográficos
Autores principales: Boehm, W, Emmel, M, Sreeram, N
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3232577/
https://www.ncbi.nlm.nih.gov/pubmed/22368670
_version_ 1782218380744327168
author Boehm, W
Emmel, M
Sreeram, N
author_facet Boehm, W
Emmel, M
Sreeram, N
author_sort Boehm, W
collection PubMed
description Following its introduction into clinical practice, the Amplatzer duct occluder (ADO) has achieved a definite place in the armamentarium of the interventional cardiologist for the closure of moderate to large sized PDAs. The device combines ease of use, including retrievability and repositioning when required, and a high occlusion rate (>99% complete occlusion of PDA within 6 months of implant, with the majority of occlusions occurring within 24 hours of implant). Possible complications, such as device embolization, protrusion of the retention disc of the device into the aorta producing aortic obstruction, or obstruction of a branch pulmonary artery by the device are also uncommon and can be avoided by choosing the appropriate sized device (with the pulmonary end of the device being 2mm larger in diameter than the minimum measured ductal diameter), and paying scrupulous attention to technique of deployment. The device can be safely deployed in infants >3.5 kg, and can currently close PDAs of upto 11 to 12mm in minimum diameter. A brief description of the device, the technique of implantation, and the clinical results to date are provided.
format Online
Article
Text
id pubmed-3232577
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-32325772012-02-22 The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome Boehm, W Emmel, M Sreeram, N Images Paediatr Cardiol Original Article Following its introduction into clinical practice, the Amplatzer duct occluder (ADO) has achieved a definite place in the armamentarium of the interventional cardiologist for the closure of moderate to large sized PDAs. The device combines ease of use, including retrievability and repositioning when required, and a high occlusion rate (>99% complete occlusion of PDA within 6 months of implant, with the majority of occlusions occurring within 24 hours of implant). Possible complications, such as device embolization, protrusion of the retention disc of the device into the aorta producing aortic obstruction, or obstruction of a branch pulmonary artery by the device are also uncommon and can be avoided by choosing the appropriate sized device (with the pulmonary end of the device being 2mm larger in diameter than the minimum measured ductal diameter), and paying scrupulous attention to technique of deployment. The device can be safely deployed in infants >3.5 kg, and can currently close PDAs of upto 11 to 12mm in minimum diameter. A brief description of the device, the technique of implantation, and the clinical results to date are provided. Medknow Publications & Media Pvt Ltd 2007 /pmc/articles/PMC3232577/ /pubmed/22368670 Text en Copyright: © Images in Paediatric Cardiology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Boehm, W
Emmel, M
Sreeram, N
The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome
title The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome
title_full The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome
title_fullStr The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome
title_full_unstemmed The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome
title_short The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome
title_sort amplatzer duct occluder for pda closure: indications, technique of implantation and clinical outcome
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3232577/
https://www.ncbi.nlm.nih.gov/pubmed/22368670
work_keys_str_mv AT boehmw theamplatzerductoccluderforpdaclosureindicationstechniqueofimplantationandclinicaloutcome
AT emmelm theamplatzerductoccluderforpdaclosureindicationstechniqueofimplantationandclinicaloutcome
AT sreeramn theamplatzerductoccluderforpdaclosureindicationstechniqueofimplantationandclinicaloutcome
AT boehmw amplatzerductoccluderforpdaclosureindicationstechniqueofimplantationandclinicaloutcome
AT emmelm amplatzerductoccluderforpdaclosureindicationstechniqueofimplantationandclinicaloutcome
AT sreeramn amplatzerductoccluderforpdaclosureindicationstechniqueofimplantationandclinicaloutcome