Cargando…
Outcome and reproducibility of data concerning the Oxford unicompartmental knee arthroplasty: A structured literature review including arthroplasty registry data
BACKGROUND AND PURPOSE: The reproducibility of results and potential confounders in sample-based studies is important to consider in the assessment of studies. Comprehensive arthroplasty registers could serve as a reference dataset for comparative analyses. We analyzed an implant that is frequently...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Informa Healthcare
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3235280/ https://www.ncbi.nlm.nih.gov/pubmed/21434760 http://dx.doi.org/10.3109/17453674.2011.566134 |
_version_ | 1782218583824138240 |
---|---|
author | Labek, Gerold Sekyra, Kathrin Pawelka, Wolfram Janda, Wolfgang Stöckl, Bernd |
author_facet | Labek, Gerold Sekyra, Kathrin Pawelka, Wolfram Janda, Wolfgang Stöckl, Bernd |
author_sort | Labek, Gerold |
collection | PubMed |
description | BACKGROUND AND PURPOSE: The reproducibility of results and potential confounders in sample-based studies is important to consider in the assessment of studies. Comprehensive arthroplasty registers could serve as a reference dataset for comparative analyses. We analyzed an implant that is frequently used worldwide, the Oxford unicompartmental knee replacement, in order to identify potential confounders inherent in the datasets and to evaluate the outcome achieved with this implant. METHODS: We performed a structured literature review of the data published on the revision rate of the Oxford medial unicompartmental arthroplasty. Both clinical follow-up studies and worldwide registry data were included. Confidence intervals were calculated to determine the statistical significance of differences. RESULTS: A substantial proportion of the published data (52–68% depending on the method of calculation) is derived from studies involving participation of the institution that developed the implant. The results published by this group show a statistically significant deviation from the reference datasets from registers or independent studies. Data from the developing hospital show mean revision rates that are 4 times lower than those based on worldwide register data, and 3 times lower than the ones quoted in independent studies. On average, the data published in independent studies are reproducible in registry data. INTERPRETATION: A conventional meta-analysis of clinical studies is substantially affected by the influence of the developing hospital, and is therefore subject to bias. For assessment of the outcome of implants, registry data are superior and, in terms of reference data for the detection of potential bias factors in the literature, could make an essential contribution to meta-analyses. |
format | Online Article Text |
id | pubmed-3235280 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Informa Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-32352802011-12-16 Outcome and reproducibility of data concerning the Oxford unicompartmental knee arthroplasty: A structured literature review including arthroplasty registry data Labek, Gerold Sekyra, Kathrin Pawelka, Wolfram Janda, Wolfgang Stöckl, Bernd Acta Orthop Article BACKGROUND AND PURPOSE: The reproducibility of results and potential confounders in sample-based studies is important to consider in the assessment of studies. Comprehensive arthroplasty registers could serve as a reference dataset for comparative analyses. We analyzed an implant that is frequently used worldwide, the Oxford unicompartmental knee replacement, in order to identify potential confounders inherent in the datasets and to evaluate the outcome achieved with this implant. METHODS: We performed a structured literature review of the data published on the revision rate of the Oxford medial unicompartmental arthroplasty. Both clinical follow-up studies and worldwide registry data were included. Confidence intervals were calculated to determine the statistical significance of differences. RESULTS: A substantial proportion of the published data (52–68% depending on the method of calculation) is derived from studies involving participation of the institution that developed the implant. The results published by this group show a statistically significant deviation from the reference datasets from registers or independent studies. Data from the developing hospital show mean revision rates that are 4 times lower than those based on worldwide register data, and 3 times lower than the ones quoted in independent studies. On average, the data published in independent studies are reproducible in registry data. INTERPRETATION: A conventional meta-analysis of clinical studies is substantially affected by the influence of the developing hospital, and is therefore subject to bias. For assessment of the outcome of implants, registry data are superior and, in terms of reference data for the detection of potential bias factors in the literature, could make an essential contribution to meta-analyses. Informa Healthcare 2011-04 2011-04-05 /pmc/articles/PMC3235280/ /pubmed/21434760 http://dx.doi.org/10.3109/17453674.2011.566134 Text en Copyright: © Nordic Orthopaedic Federation http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited. |
spellingShingle | Article Labek, Gerold Sekyra, Kathrin Pawelka, Wolfram Janda, Wolfgang Stöckl, Bernd Outcome and reproducibility of data concerning the Oxford unicompartmental knee arthroplasty: A structured literature review including arthroplasty registry data |
title | Outcome and reproducibility of data concerning the Oxford unicompartmental knee arthroplasty: A structured literature review including arthroplasty registry data |
title_full | Outcome and reproducibility of data concerning the Oxford unicompartmental knee arthroplasty: A structured literature review including arthroplasty registry data |
title_fullStr | Outcome and reproducibility of data concerning the Oxford unicompartmental knee arthroplasty: A structured literature review including arthroplasty registry data |
title_full_unstemmed | Outcome and reproducibility of data concerning the Oxford unicompartmental knee arthroplasty: A structured literature review including arthroplasty registry data |
title_short | Outcome and reproducibility of data concerning the Oxford unicompartmental knee arthroplasty: A structured literature review including arthroplasty registry data |
title_sort | outcome and reproducibility of data concerning the oxford unicompartmental knee arthroplasty: a structured literature review including arthroplasty registry data |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3235280/ https://www.ncbi.nlm.nih.gov/pubmed/21434760 http://dx.doi.org/10.3109/17453674.2011.566134 |
work_keys_str_mv | AT labekgerold outcomeandreproducibilityofdataconcerningtheoxfordunicompartmentalkneearthroplastyastructuredliteraturereviewincludingarthroplastyregistrydata AT sekyrakathrin outcomeandreproducibilityofdataconcerningtheoxfordunicompartmentalkneearthroplastyastructuredliteraturereviewincludingarthroplastyregistrydata AT pawelkawolfram outcomeandreproducibilityofdataconcerningtheoxfordunicompartmentalkneearthroplastyastructuredliteraturereviewincludingarthroplastyregistrydata AT jandawolfgang outcomeandreproducibilityofdataconcerningtheoxfordunicompartmentalkneearthroplastyastructuredliteraturereviewincludingarthroplastyregistrydata AT stocklbernd outcomeandreproducibilityofdataconcerningtheoxfordunicompartmentalkneearthroplastyastructuredliteraturereviewincludingarthroplastyregistrydata |