Cargando…

Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008: A report from the Norwegian Arthroplasty Register

BACKGROUND AND PURPOSE: Improvement of positioning and alignment by the use of computer-assisted surgery (CAS) might improve longevity and function in total knee replacements, but there is little evidence. In this study, we evaluated the short-term results of computer-navigated knee replacements bas...

Descripción completa

Detalles Bibliográficos
Autores principales: Gøthesen, Øystein, Espehaug, Birgitte, Havelin, Leif, Petursson, Gunnar, Furnes, Ove
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Informa Healthcare 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3235306/
https://www.ncbi.nlm.nih.gov/pubmed/21504309
http://dx.doi.org/10.3109/17453674.2011.575743
_version_ 1782218589811507200
author Gøthesen, Øystein
Espehaug, Birgitte
Havelin, Leif
Petursson, Gunnar
Furnes, Ove
author_facet Gøthesen, Øystein
Espehaug, Birgitte
Havelin, Leif
Petursson, Gunnar
Furnes, Ove
author_sort Gøthesen, Øystein
collection PubMed
description BACKGROUND AND PURPOSE: Improvement of positioning and alignment by the use of computer-assisted surgery (CAS) might improve longevity and function in total knee replacements, but there is little evidence. In this study, we evaluated the short-term results of computer-navigated knee replacements based on data from the Norwegian Arthroplasty Register. PATIENTS AND METHODS: Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005–2008, were evaluated. The 5 most common implants and the 3 most common navigation systems were selected. Cemented, uncemented, and hybrid knees were included. With the risk of revision for any cause as the primary endpoint and intraoperative complications and operating time as secondary outcomes, 1,465 computer-navigated knee replacements (CAS) and 8,214 conventionally operated knee replacements (CON) were compared. Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis, and ASA category were used. RESULTS: Kaplan-Meier estimated survival at 2 years was 98% (95% CI: 97.5–98.3) in the CON group and 96% (95% CI: 95.0–97.8) in the CAS group. The adjusted Cox regression analysis showed a higher risk of revision in the CAS group (RR = 1.7, 95% CI: 1.1–2.5; p = 0.02). The LCS Complete knee had a higher risk of revision with CAS than with CON (RR = 2.1, 95% CI: 1.3–3.4; p = 0.004)). The differences were not statistically significant for the other prosthesis brands. Mean operating time was 15 min longer in the CAS group. INTERPRETATION: With the introduction of computer-navigated knee replacement surgery in Norway, the short-term risk of revision has increased for computer-navigated replacement with the LCS Complete. The mechanisms of failure of these implantations should be explored in greater depth, and in this study we have not been able to draw conclusions regarding causation.
format Online
Article
Text
id pubmed-3235306
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Informa Healthcare
record_format MEDLINE/PubMed
spelling pubmed-32353062011-12-16 Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008: A report from the Norwegian Arthroplasty Register Gøthesen, Øystein Espehaug, Birgitte Havelin, Leif Petursson, Gunnar Furnes, Ove Acta Orthop Article BACKGROUND AND PURPOSE: Improvement of positioning and alignment by the use of computer-assisted surgery (CAS) might improve longevity and function in total knee replacements, but there is little evidence. In this study, we evaluated the short-term results of computer-navigated knee replacements based on data from the Norwegian Arthroplasty Register. PATIENTS AND METHODS: Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005–2008, were evaluated. The 5 most common implants and the 3 most common navigation systems were selected. Cemented, uncemented, and hybrid knees were included. With the risk of revision for any cause as the primary endpoint and intraoperative complications and operating time as secondary outcomes, 1,465 computer-navigated knee replacements (CAS) and 8,214 conventionally operated knee replacements (CON) were compared. Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis, and ASA category were used. RESULTS: Kaplan-Meier estimated survival at 2 years was 98% (95% CI: 97.5–98.3) in the CON group and 96% (95% CI: 95.0–97.8) in the CAS group. The adjusted Cox regression analysis showed a higher risk of revision in the CAS group (RR = 1.7, 95% CI: 1.1–2.5; p = 0.02). The LCS Complete knee had a higher risk of revision with CAS than with CON (RR = 2.1, 95% CI: 1.3–3.4; p = 0.004)). The differences were not statistically significant for the other prosthesis brands. Mean operating time was 15 min longer in the CAS group. INTERPRETATION: With the introduction of computer-navigated knee replacement surgery in Norway, the short-term risk of revision has increased for computer-navigated replacement with the LCS Complete. The mechanisms of failure of these implantations should be explored in greater depth, and in this study we have not been able to draw conclusions regarding causation. Informa Healthcare 2011-06 2011-07-08 /pmc/articles/PMC3235306/ /pubmed/21504309 http://dx.doi.org/10.3109/17453674.2011.575743 Text en Copyright: © Nordic Orthopaedic Federation http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited.
spellingShingle Article
Gøthesen, Øystein
Espehaug, Birgitte
Havelin, Leif
Petursson, Gunnar
Furnes, Ove
Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008: A report from the Norwegian Arthroplasty Register
title Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008: A report from the Norwegian Arthroplasty Register
title_full Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008: A report from the Norwegian Arthroplasty Register
title_fullStr Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008: A report from the Norwegian Arthroplasty Register
title_full_unstemmed Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008: A report from the Norwegian Arthroplasty Register
title_short Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008: A report from the Norwegian Arthroplasty Register
title_sort short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008: a report from the norwegian arthroplasty register
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3235306/
https://www.ncbi.nlm.nih.gov/pubmed/21504309
http://dx.doi.org/10.3109/17453674.2011.575743
work_keys_str_mv AT gøthesenøystein shorttermoutcomeof1465computernavigatedprimarytotalkneereplacements20052008areportfromthenorwegianarthroplastyregister
AT espehaugbirgitte shorttermoutcomeof1465computernavigatedprimarytotalkneereplacements20052008areportfromthenorwegianarthroplastyregister
AT havelinleif shorttermoutcomeof1465computernavigatedprimarytotalkneereplacements20052008areportfromthenorwegianarthroplastyregister
AT peturssongunnar shorttermoutcomeof1465computernavigatedprimarytotalkneereplacements20052008areportfromthenorwegianarthroplastyregister
AT furnesove shorttermoutcomeof1465computernavigatedprimarytotalkneereplacements20052008areportfromthenorwegianarthroplastyregister