Changing from analog to digital images: Does it affect the accuracy of alignment measurements of the lower extremity?

BACKGROUND AND PURPOSE: Medical imaging has changed from analog films to digital media. We examined and compared the accuracy of orthopedic measurements using different media. METHODS: Before knee arthroplasty, full-length standing radiographs of 52 legs were obtained. The mechanical axis (MA), tibi...

Descripción completa

Detalles Bibliográficos
Autores principales: Lohman, Martina, Tallroth, Kaj, Kettunen, Jyrki A, Remes, Ville
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Informa Healthcare 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3235315/
https://www.ncbi.nlm.nih.gov/pubmed/21619504
http://dx.doi.org/10.3109/17453674.2011.570670
_version_ 1782218591876153344
author Lohman, Martina
Tallroth, Kaj
Kettunen, Jyrki A
Remes, Ville
author_facet Lohman, Martina
Tallroth, Kaj
Kettunen, Jyrki A
Remes, Ville
author_sort Lohman, Martina
collection PubMed
description BACKGROUND AND PURPOSE: Medical imaging has changed from analog films to digital media. We examined and compared the accuracy of orthopedic measurements using different media. METHODS: Before knee arthroplasty, full-length standing radiographs of 52 legs were obtained. The mechanical axis (MA), tibio-femoral angle (TFA), and femur angle (FA) were measured and analyzed twice, by 2 radiologists, using (1) true-size films, (2) short films, (3) a digital high-resolution workstation, and (4) a web-based personal computer. The agreement between the 4 media was evaluated using the Bland-Altman method (limits of agreement) using the true-size films as a reference standard. RESULTS: The mean differences in measurements between the traditional true-size films and the 3 other methods were small: for MA –0.20 to 0.07 degrees, and for TFA –0.02 to 0.18 degrees. Also, the limits of agreement between the traditional true-size films and the three other methods were small. INTERPRETATION: The agreement of the alignment measurements across the 4 different media was good. Orthopedic angles can be measured as accurately from analog films as from digital screens, regardless of film or monitor size.
format Online
Article
Text
id pubmed-3235315
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Informa Healthcare
record_format MEDLINE/PubMed
spelling pubmed-32353152011-12-16 Changing from analog to digital images: Does it affect the accuracy of alignment measurements of the lower extremity? Lohman, Martina Tallroth, Kaj Kettunen, Jyrki A Remes, Ville Acta Orthop Article BACKGROUND AND PURPOSE: Medical imaging has changed from analog films to digital media. We examined and compared the accuracy of orthopedic measurements using different media. METHODS: Before knee arthroplasty, full-length standing radiographs of 52 legs were obtained. The mechanical axis (MA), tibio-femoral angle (TFA), and femur angle (FA) were measured and analyzed twice, by 2 radiologists, using (1) true-size films, (2) short films, (3) a digital high-resolution workstation, and (4) a web-based personal computer. The agreement between the 4 media was evaluated using the Bland-Altman method (limits of agreement) using the true-size films as a reference standard. RESULTS: The mean differences in measurements between the traditional true-size films and the 3 other methods were small: for MA –0.20 to 0.07 degrees, and for TFA –0.02 to 0.18 degrees. Also, the limits of agreement between the traditional true-size films and the three other methods were small. INTERPRETATION: The agreement of the alignment measurements across the 4 different media was good. Orthopedic angles can be measured as accurately from analog films as from digital screens, regardless of film or monitor size. Informa Healthcare 2011-06 2011-07-08 /pmc/articles/PMC3235315/ /pubmed/21619504 http://dx.doi.org/10.3109/17453674.2011.570670 Text en Copyright: © Nordic Orthopaedic Federation http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited.
spellingShingle Article
Lohman, Martina
Tallroth, Kaj
Kettunen, Jyrki A
Remes, Ville
Changing from analog to digital images: Does it affect the accuracy of alignment measurements of the lower extremity?
title Changing from analog to digital images: Does it affect the accuracy of alignment measurements of the lower extremity?
title_full Changing from analog to digital images: Does it affect the accuracy of alignment measurements of the lower extremity?
title_fullStr Changing from analog to digital images: Does it affect the accuracy of alignment measurements of the lower extremity?
title_full_unstemmed Changing from analog to digital images: Does it affect the accuracy of alignment measurements of the lower extremity?
title_short Changing from analog to digital images: Does it affect the accuracy of alignment measurements of the lower extremity?
title_sort changing from analog to digital images: does it affect the accuracy of alignment measurements of the lower extremity?
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3235315/
https://www.ncbi.nlm.nih.gov/pubmed/21619504
http://dx.doi.org/10.3109/17453674.2011.570670
work_keys_str_mv AT lohmanmartina changingfromanalogtodigitalimagesdoesitaffecttheaccuracyofalignmentmeasurementsofthelowerextremity
AT tallrothkaj changingfromanalogtodigitalimagesdoesitaffecttheaccuracyofalignmentmeasurementsofthelowerextremity
AT kettunenjyrkia changingfromanalogtodigitalimagesdoesitaffecttheaccuracyofalignmentmeasurementsofthelowerextremity
AT remesville changingfromanalogtodigitalimagesdoesitaffecttheaccuracyofalignmentmeasurementsofthelowerextremity