Cargando…
The NTD Nanoscope: potential applications and implementations
BACKGROUND: Nanopore transduction detection (NTD) offers prospects for a number of highly sensitive and discriminative applications, including: (i) single nucleotide polymorphism (SNP) detection; (ii) targeted DNA re-sequencing; (iii) protein isoform assaying; and (iv) biosensing via antibody or apt...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3236844/ https://www.ncbi.nlm.nih.gov/pubmed/22166072 http://dx.doi.org/10.1186/1471-2105-12-S10-S21 |
_version_ | 1782218794755686400 |
---|---|
author | Winters-Hilt, Stephen Horton-Chao, Evenie Morales, Eric |
author_facet | Winters-Hilt, Stephen Horton-Chao, Evenie Morales, Eric |
author_sort | Winters-Hilt, Stephen |
collection | PubMed |
description | BACKGROUND: Nanopore transduction detection (NTD) offers prospects for a number of highly sensitive and discriminative applications, including: (i) single nucleotide polymorphism (SNP) detection; (ii) targeted DNA re-sequencing; (iii) protein isoform assaying; and (iv) biosensing via antibody or aptamer coupled molecules. Nanopore event transduction involves single-molecule biophysics, engineered information flows, and nanopore cheminformatics. The NTD Nanoscope has seen limited use in the scientific community, however, due to lack of information about potential applications, and lack of availability for the device itself. Meta Logos Inc. is developing both pre-packaged device platforms and component-level (unassembled) kit platforms (the latter described here). In both cases a lipid bi-layer workstation is first established, then augmentations and operational protocols are provided to have a nanopore transduction detector. In this paper we provide an overview of the NTD Nanoscope applications and implementations. The NTD Nanoscope Kit, in particular, is a component-level reproduction of the standard NTD device used in previous research papers. RESULTS: The NTD Nanoscope method is shown to functionalize a single nanopore with a channel current modulator that is designed to transduce events, such as binding to a specific target. To expedite set-up in new lab settings, the calibration and troubleshooting for the NTD Nanoscope kit components and signal processing software, the NTD Nanoscope Kit, is designed to include a set of test buffers and control molecules based on experiments described in previous NTD papers (the model systems briefly described in what follows). The description of the Server-interfacing for advanced signal processing support is also briefly mentioned. CONCLUSIONS: SNP assaying, SNP discovery, DNA sequencing and RNA-seq methods are typically limited by the accuracy of the error rate of the enzymes involved, such as methods involving the polymerase chain reaction (PCR) enzyme. The NTD Nanoscope offers a means to obtain higher accuracy as it is a single-molecule method that does not inherently involve use of enzymes, using a functionalized nanopore instead. |
format | Online Article Text |
id | pubmed-3236844 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-32368442011-12-14 The NTD Nanoscope: potential applications and implementations Winters-Hilt, Stephen Horton-Chao, Evenie Morales, Eric BMC Bioinformatics Proceedings BACKGROUND: Nanopore transduction detection (NTD) offers prospects for a number of highly sensitive and discriminative applications, including: (i) single nucleotide polymorphism (SNP) detection; (ii) targeted DNA re-sequencing; (iii) protein isoform assaying; and (iv) biosensing via antibody or aptamer coupled molecules. Nanopore event transduction involves single-molecule biophysics, engineered information flows, and nanopore cheminformatics. The NTD Nanoscope has seen limited use in the scientific community, however, due to lack of information about potential applications, and lack of availability for the device itself. Meta Logos Inc. is developing both pre-packaged device platforms and component-level (unassembled) kit platforms (the latter described here). In both cases a lipid bi-layer workstation is first established, then augmentations and operational protocols are provided to have a nanopore transduction detector. In this paper we provide an overview of the NTD Nanoscope applications and implementations. The NTD Nanoscope Kit, in particular, is a component-level reproduction of the standard NTD device used in previous research papers. RESULTS: The NTD Nanoscope method is shown to functionalize a single nanopore with a channel current modulator that is designed to transduce events, such as binding to a specific target. To expedite set-up in new lab settings, the calibration and troubleshooting for the NTD Nanoscope kit components and signal processing software, the NTD Nanoscope Kit, is designed to include a set of test buffers and control molecules based on experiments described in previous NTD papers (the model systems briefly described in what follows). The description of the Server-interfacing for advanced signal processing support is also briefly mentioned. CONCLUSIONS: SNP assaying, SNP discovery, DNA sequencing and RNA-seq methods are typically limited by the accuracy of the error rate of the enzymes involved, such as methods involving the polymerase chain reaction (PCR) enzyme. The NTD Nanoscope offers a means to obtain higher accuracy as it is a single-molecule method that does not inherently involve use of enzymes, using a functionalized nanopore instead. BioMed Central 2011-10-18 /pmc/articles/PMC3236844/ /pubmed/22166072 http://dx.doi.org/10.1186/1471-2105-12-S10-S21 Text en Copyright ©2011 Winters-Hilt et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Proceedings Winters-Hilt, Stephen Horton-Chao, Evenie Morales, Eric The NTD Nanoscope: potential applications and implementations |
title | The NTD Nanoscope: potential applications and implementations |
title_full | The NTD Nanoscope: potential applications and implementations |
title_fullStr | The NTD Nanoscope: potential applications and implementations |
title_full_unstemmed | The NTD Nanoscope: potential applications and implementations |
title_short | The NTD Nanoscope: potential applications and implementations |
title_sort | ntd nanoscope: potential applications and implementations |
topic | Proceedings |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3236844/ https://www.ncbi.nlm.nih.gov/pubmed/22166072 http://dx.doi.org/10.1186/1471-2105-12-S10-S21 |
work_keys_str_mv | AT wintershiltstephen thentdnanoscopepotentialapplicationsandimplementations AT hortonchaoevenie thentdnanoscopepotentialapplicationsandimplementations AT moraleseric thentdnanoscopepotentialapplicationsandimplementations AT wintershiltstephen ntdnanoscopepotentialapplicationsandimplementations AT hortonchaoevenie ntdnanoscopepotentialapplicationsandimplementations AT moraleseric ntdnanoscopepotentialapplicationsandimplementations |