Cargando…

Effects of hydroxyapatite coating on survival of an uncemented femoral stem: A Swedish Hip Arthroplasty Register study on 4,772 hips

BACKGROUND AND PURPOSE: Hydroxyapatite (HA) is widely used as a coating for uncemented total hip arthroplasty components. This has been suggested to improve implant ingrowth and long-term stability. However, the evidence behind the use of HA coating on femoral stems is ambiguous. We investigated sur...

Descripción completa

Detalles Bibliográficos
Autores principales: Lazarinis, Stergios, Kärrholm, Johan, Hailer, Nils P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Informa Healthcare 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3237027/
https://www.ncbi.nlm.nih.gov/pubmed/21751858
http://dx.doi.org/10.3109/17453674.2011.597699
_version_ 1782218833487986688
author Lazarinis, Stergios
Kärrholm, Johan
Hailer, Nils P
author_facet Lazarinis, Stergios
Kärrholm, Johan
Hailer, Nils P
author_sort Lazarinis, Stergios
collection PubMed
description BACKGROUND AND PURPOSE: Hydroxyapatite (HA) is widely used as a coating for uncemented total hip arthroplasty components. This has been suggested to improve implant ingrowth and long-term stability. However, the evidence behind the use of HA coating on femoral stems is ambiguous. We investigated survival of an uncemented, tapered titanium femoral stem that was available either with or without HA coating (Bi-Metric). PATIENTS AND METHODS: The stem had been used in 4,772 total hip arthroplasties (THAs) in 4,169 patients registered in the Swedish Hip Arthroplasty Register between 1992 and 2009. 59% of the stems investigated were coated with HA and 41% were uncoated. Kaplan-Meier survival analysis and a Cox regression model with adjustment for age, sex, primary diagnosis, and the type of cup fixation were used to calculate survival rates and adjusted risk ratios (RRs) of the risk of revision for various reasons. RESULTS: The 10-year survival rates of the HA-coated version and the uncoated version were about equal when we used revision for any reason as the endpoint: 98% (95% CI: 98–99) and 98% (CI: 97–99), respectively. A Cox regression model adjusting for the covariates mentioned above showed that the presence of HA coating did not have any influence on the risk of stem revision for any reason (RR = 1.0, 95% CI: 0.6–1.6) or due to aseptic loosening (RR = 0.5, CI: 0.2–1.5). There was no effect of HA coating on the risk of stem revision due to infection, dislocation, or fracture. INTERPRETATION: The uncemented Bi-Metric stem showed excellent 10-year survival. Our findings do not support the use of HA coating on this stem to enhance implant survival.
format Online
Article
Text
id pubmed-3237027
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Informa Healthcare
record_format MEDLINE/PubMed
spelling pubmed-32370272012-01-03 Effects of hydroxyapatite coating on survival of an uncemented femoral stem: A Swedish Hip Arthroplasty Register study on 4,772 hips Lazarinis, Stergios Kärrholm, Johan Hailer, Nils P Acta Orthop Article BACKGROUND AND PURPOSE: Hydroxyapatite (HA) is widely used as a coating for uncemented total hip arthroplasty components. This has been suggested to improve implant ingrowth and long-term stability. However, the evidence behind the use of HA coating on femoral stems is ambiguous. We investigated survival of an uncemented, tapered titanium femoral stem that was available either with or without HA coating (Bi-Metric). PATIENTS AND METHODS: The stem had been used in 4,772 total hip arthroplasties (THAs) in 4,169 patients registered in the Swedish Hip Arthroplasty Register between 1992 and 2009. 59% of the stems investigated were coated with HA and 41% were uncoated. Kaplan-Meier survival analysis and a Cox regression model with adjustment for age, sex, primary diagnosis, and the type of cup fixation were used to calculate survival rates and adjusted risk ratios (RRs) of the risk of revision for various reasons. RESULTS: The 10-year survival rates of the HA-coated version and the uncoated version were about equal when we used revision for any reason as the endpoint: 98% (95% CI: 98–99) and 98% (CI: 97–99), respectively. A Cox regression model adjusting for the covariates mentioned above showed that the presence of HA coating did not have any influence on the risk of stem revision for any reason (RR = 1.0, 95% CI: 0.6–1.6) or due to aseptic loosening (RR = 0.5, CI: 0.2–1.5). There was no effect of HA coating on the risk of stem revision due to infection, dislocation, or fracture. INTERPRETATION: The uncemented Bi-Metric stem showed excellent 10-year survival. Our findings do not support the use of HA coating on this stem to enhance implant survival. Informa Healthcare 2011-08 2011-09-02 /pmc/articles/PMC3237027/ /pubmed/21751858 http://dx.doi.org/10.3109/17453674.2011.597699 Text en Copyright: © Nordic Orthopaedic Federation http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited.
spellingShingle Article
Lazarinis, Stergios
Kärrholm, Johan
Hailer, Nils P
Effects of hydroxyapatite coating on survival of an uncemented femoral stem: A Swedish Hip Arthroplasty Register study on 4,772 hips
title Effects of hydroxyapatite coating on survival of an uncemented femoral stem: A Swedish Hip Arthroplasty Register study on 4,772 hips
title_full Effects of hydroxyapatite coating on survival of an uncemented femoral stem: A Swedish Hip Arthroplasty Register study on 4,772 hips
title_fullStr Effects of hydroxyapatite coating on survival of an uncemented femoral stem: A Swedish Hip Arthroplasty Register study on 4,772 hips
title_full_unstemmed Effects of hydroxyapatite coating on survival of an uncemented femoral stem: A Swedish Hip Arthroplasty Register study on 4,772 hips
title_short Effects of hydroxyapatite coating on survival of an uncemented femoral stem: A Swedish Hip Arthroplasty Register study on 4,772 hips
title_sort effects of hydroxyapatite coating on survival of an uncemented femoral stem: a swedish hip arthroplasty register study on 4,772 hips
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3237027/
https://www.ncbi.nlm.nih.gov/pubmed/21751858
http://dx.doi.org/10.3109/17453674.2011.597699
work_keys_str_mv AT lazarinisstergios effectsofhydroxyapatitecoatingonsurvivalofanuncementedfemoralstemaswedishhiparthroplastyregisterstudyon4772hips
AT karrholmjohan effectsofhydroxyapatitecoatingonsurvivalofanuncementedfemoralstemaswedishhiparthroplastyregisterstudyon4772hips
AT hailernilsp effectsofhydroxyapatitecoatingonsurvivalofanuncementedfemoralstemaswedishhiparthroplastyregisterstudyon4772hips