Validation of four automatic devices for self-measurement of blood pressure according to the international protocol of the European Society of Hypertension
BACKGROUND: Four oscillometric devices for self-measurement of blood pressure (SBPM) were evaluated according to the European Society of Hypertension (ESH) international protocol and its 2010 revision in four separate studies. The Omron(®) M2, Omron M3, and Omron M6 measure blood pressure (BP) at th...
Autores principales: | Topouchian, Jirar, Agnoletti, Davide, Blacher, Jacques, Youssef, Ahmed, Ibanez, Isabel, Khabouth, Jose, Khawaja, Salwa, Beaino, Layale, Asmar, Roland |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3237100/ https://www.ncbi.nlm.nih.gov/pubmed/22174581 http://dx.doi.org/10.2147/VHRM.S27193 |
Ejemplares similares
-
Validation of four devices: Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 for home blood pressure measurement according to the European Society of Hypertension International Protocol
por: Topouchian, Jirar, et al.
Publicado: (2014) -
Validation of the Withings BPM Core Device for Self-Blood Pressure Measurements in General Population According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard
por: Hakobyan, Zoya, et al.
Publicado: (2023) -
Clinical Accuracy of the Withings BPM Connect for Self-Blood Pressure Measurements in Pregnancy and Pre-Eclampsia: Validation According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard
por: Zelveian, Parounak, et al.
Publicado: (2022) -
Accuracy of the Withings BPM Connect Device for Self-Blood Pressure Measurements in General Population – Validation According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard
por: Topouchian, Jirar, et al.
Publicado: (2022) -
Accuracy of the COMBEI BP118A Device for Self-Blood Pressure Measurements in General Population – Validation According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard
por: Tasić, Nebojsa, et al.
Publicado: (2022)