Cargando…
Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties
BACKGROUND AND PURPOSE: Soft tissue necrobiosis and T-lymphocyte infiltration within the periprosthetic soft tissue have been linked to a suggested hypersensitivity reaction of the delayed-type following the metal-on-metal arthroplasty. While we observed both synovial necrobiosis and lymphocyte infi...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Informa Healthcare
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3242957/ https://www.ncbi.nlm.nih.gov/pubmed/22112191 http://dx.doi.org/10.3109/17453674.2011.625534 |
_version_ | 1782219658443620352 |
---|---|
author | von Domarus, Christoph Rosenberg, Jens P Rüther, Wolfgang Zustin, Jozef |
author_facet | von Domarus, Christoph Rosenberg, Jens P Rüther, Wolfgang Zustin, Jozef |
author_sort | von Domarus, Christoph |
collection | PubMed |
description | BACKGROUND AND PURPOSE: Soft tissue necrobiosis and T-lymphocyte infiltration within the periprosthetic soft tissue have been linked to a suggested hypersensitivity reaction of the delayed-type following the metal-on-metal arthroplasty. While we observed both synovial necrobiosis and lymphocyte infiltrates in synovial tissues with failed metal-on-polyethylene prostheses, we hypothesized that both findings are unspecific for metal-on-metal bearing coupes. Thus, we wished to quantify the extent of necrobiosis and the amount of T-lymphocyte infiltration in aseptically loosened metal-on-polyethylene prostheses. MATERIALS AND METHODS: We analyzed 28 consecutive synovial biopsy specimens obtained at revision surgery of aseptically loosened metal-on-polyethylene prostheses (19 hips and 9 knees) and quantified both the extent of necrobiosis vertically and the density of CD3+, CD4+, and CD8+ lymphocytes within the joint capsular tissue. We excluded patients with inflammatory skeletal disease or with a history of metal hypersensitivity. RESULTS: We found necrobiosis in 23 of 28 cases and it was most often connected with the superficial portions of the synovium. Necrobiosis of deeper tissues was seen in 8 specimens and it was strongly associated with superficial necrobiosis. While CD3+ lymphocytes were detected in each biopsy, 4 cases with more than 300 CD3+ lymphocytes were identified in the group of 26 cases that presented with more than 100 CD3+ lymphocytes within one high-power field. 16 cases with more than 100 CD3+ lymphocytes also showed concomitant superficial necrobiosis of the synovium. In the inflammatory infiltration of periprosthetic synovium, CD8+ lymphocytes predominated over CD4+ cells. INTERPRETATION: Synovial necrobiosis and infiltration of T-lymphocytes are common findings in tissues around aseptically loosened metal-on-polyethylene arthroplasty in patients without a clinically suspected metal hypersensitivity reaction. Thus, neither necrobiosis nor infiltration of T-lymphocytes should be considered to be specific for failed metal-on-metal bearings or metal hypersensitivity reaction. |
format | Online Article Text |
id | pubmed-3242957 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Informa Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-32429572012-01-03 Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties von Domarus, Christoph Rosenberg, Jens P Rüther, Wolfgang Zustin, Jozef Acta Orthop Article BACKGROUND AND PURPOSE: Soft tissue necrobiosis and T-lymphocyte infiltration within the periprosthetic soft tissue have been linked to a suggested hypersensitivity reaction of the delayed-type following the metal-on-metal arthroplasty. While we observed both synovial necrobiosis and lymphocyte infiltrates in synovial tissues with failed metal-on-polyethylene prostheses, we hypothesized that both findings are unspecific for metal-on-metal bearing coupes. Thus, we wished to quantify the extent of necrobiosis and the amount of T-lymphocyte infiltration in aseptically loosened metal-on-polyethylene prostheses. MATERIALS AND METHODS: We analyzed 28 consecutive synovial biopsy specimens obtained at revision surgery of aseptically loosened metal-on-polyethylene prostheses (19 hips and 9 knees) and quantified both the extent of necrobiosis vertically and the density of CD3+, CD4+, and CD8+ lymphocytes within the joint capsular tissue. We excluded patients with inflammatory skeletal disease or with a history of metal hypersensitivity. RESULTS: We found necrobiosis in 23 of 28 cases and it was most often connected with the superficial portions of the synovium. Necrobiosis of deeper tissues was seen in 8 specimens and it was strongly associated with superficial necrobiosis. While CD3+ lymphocytes were detected in each biopsy, 4 cases with more than 300 CD3+ lymphocytes were identified in the group of 26 cases that presented with more than 100 CD3+ lymphocytes within one high-power field. 16 cases with more than 100 CD3+ lymphocytes also showed concomitant superficial necrobiosis of the synovium. In the inflammatory infiltration of periprosthetic synovium, CD8+ lymphocytes predominated over CD4+ cells. INTERPRETATION: Synovial necrobiosis and infiltration of T-lymphocytes are common findings in tissues around aseptically loosened metal-on-polyethylene arthroplasty in patients without a clinically suspected metal hypersensitivity reaction. Thus, neither necrobiosis nor infiltration of T-lymphocytes should be considered to be specific for failed metal-on-metal bearings or metal hypersensitivity reaction. Informa Healthcare 2011-10 2011-11-24 /pmc/articles/PMC3242957/ /pubmed/22112191 http://dx.doi.org/10.3109/17453674.2011.625534 Text en Copyright: © Nordic Orthopaedic Federation http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited. |
spellingShingle | Article von Domarus, Christoph Rosenberg, Jens P Rüther, Wolfgang Zustin, Jozef Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties |
title | Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties |
title_full | Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties |
title_fullStr | Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties |
title_full_unstemmed | Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties |
title_short | Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties |
title_sort | necrobiosis and t-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3242957/ https://www.ncbi.nlm.nih.gov/pubmed/22112191 http://dx.doi.org/10.3109/17453674.2011.625534 |
work_keys_str_mv | AT vondomaruschristoph necrobiosisandtlymphocyteinfiltrationinretrievedasepticallyloosenedmetalonpolyethylenearthroplasties AT rosenbergjensp necrobiosisandtlymphocyteinfiltrationinretrievedasepticallyloosenedmetalonpolyethylenearthroplasties AT rutherwolfgang necrobiosisandtlymphocyteinfiltrationinretrievedasepticallyloosenedmetalonpolyethylenearthroplasties AT zustinjozef necrobiosisandtlymphocyteinfiltrationinretrievedasepticallyloosenedmetalonpolyethylenearthroplasties |