Cargando…

Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties

BACKGROUND AND PURPOSE: Soft tissue necrobiosis and T-lymphocyte infiltration within the periprosthetic soft tissue have been linked to a suggested hypersensitivity reaction of the delayed-type following the metal-on-metal arthroplasty. While we observed both synovial necrobiosis and lymphocyte infi...

Descripción completa

Detalles Bibliográficos
Autores principales: von Domarus, Christoph, Rosenberg, Jens P, Rüther, Wolfgang, Zustin, Jozef
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Informa Healthcare 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3242957/
https://www.ncbi.nlm.nih.gov/pubmed/22112191
http://dx.doi.org/10.3109/17453674.2011.625534
_version_ 1782219658443620352
author von Domarus, Christoph
Rosenberg, Jens P
Rüther, Wolfgang
Zustin, Jozef
author_facet von Domarus, Christoph
Rosenberg, Jens P
Rüther, Wolfgang
Zustin, Jozef
author_sort von Domarus, Christoph
collection PubMed
description BACKGROUND AND PURPOSE: Soft tissue necrobiosis and T-lymphocyte infiltration within the periprosthetic soft tissue have been linked to a suggested hypersensitivity reaction of the delayed-type following the metal-on-metal arthroplasty. While we observed both synovial necrobiosis and lymphocyte infiltrates in synovial tissues with failed metal-on-polyethylene prostheses, we hypothesized that both findings are unspecific for metal-on-metal bearing coupes. Thus, we wished to quantify the extent of necrobiosis and the amount of T-lymphocyte infiltration in aseptically loosened metal-on-polyethylene prostheses. MATERIALS AND METHODS: We analyzed 28 consecutive synovial biopsy specimens obtained at revision surgery of aseptically loosened metal-on-polyethylene prostheses (19 hips and 9 knees) and quantified both the extent of necrobiosis vertically and the density of CD3+, CD4+, and CD8+ lymphocytes within the joint capsular tissue. We excluded patients with inflammatory skeletal disease or with a history of metal hypersensitivity. RESULTS: We found necrobiosis in 23 of 28 cases and it was most often connected with the superficial portions of the synovium. Necrobiosis of deeper tissues was seen in 8 specimens and it was strongly associated with superficial necrobiosis. While CD3+ lymphocytes were detected in each biopsy, 4 cases with more than 300 CD3+ lymphocytes were identified in the group of 26 cases that presented with more than 100 CD3+ lymphocytes within one high-power field. 16 cases with more than 100 CD3+ lymphocytes also showed concomitant superficial necrobiosis of the synovium. In the inflammatory infiltration of periprosthetic synovium, CD8+ lymphocytes predominated over CD4+ cells. INTERPRETATION: Synovial necrobiosis and infiltration of T-lymphocytes are common findings in tissues around aseptically loosened metal-on-polyethylene arthroplasty in patients without a clinically suspected metal hypersensitivity reaction. Thus, neither necrobiosis nor infiltration of T-lymphocytes should be considered to be specific for failed metal-on-metal bearings or metal hypersensitivity reaction.
format Online
Article
Text
id pubmed-3242957
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Informa Healthcare
record_format MEDLINE/PubMed
spelling pubmed-32429572012-01-03 Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties von Domarus, Christoph Rosenberg, Jens P Rüther, Wolfgang Zustin, Jozef Acta Orthop Article BACKGROUND AND PURPOSE: Soft tissue necrobiosis and T-lymphocyte infiltration within the periprosthetic soft tissue have been linked to a suggested hypersensitivity reaction of the delayed-type following the metal-on-metal arthroplasty. While we observed both synovial necrobiosis and lymphocyte infiltrates in synovial tissues with failed metal-on-polyethylene prostheses, we hypothesized that both findings are unspecific for metal-on-metal bearing coupes. Thus, we wished to quantify the extent of necrobiosis and the amount of T-lymphocyte infiltration in aseptically loosened metal-on-polyethylene prostheses. MATERIALS AND METHODS: We analyzed 28 consecutive synovial biopsy specimens obtained at revision surgery of aseptically loosened metal-on-polyethylene prostheses (19 hips and 9 knees) and quantified both the extent of necrobiosis vertically and the density of CD3+, CD4+, and CD8+ lymphocytes within the joint capsular tissue. We excluded patients with inflammatory skeletal disease or with a history of metal hypersensitivity. RESULTS: We found necrobiosis in 23 of 28 cases and it was most often connected with the superficial portions of the synovium. Necrobiosis of deeper tissues was seen in 8 specimens and it was strongly associated with superficial necrobiosis. While CD3+ lymphocytes were detected in each biopsy, 4 cases with more than 300 CD3+ lymphocytes were identified in the group of 26 cases that presented with more than 100 CD3+ lymphocytes within one high-power field. 16 cases with more than 100 CD3+ lymphocytes also showed concomitant superficial necrobiosis of the synovium. In the inflammatory infiltration of periprosthetic synovium, CD8+ lymphocytes predominated over CD4+ cells. INTERPRETATION: Synovial necrobiosis and infiltration of T-lymphocytes are common findings in tissues around aseptically loosened metal-on-polyethylene arthroplasty in patients without a clinically suspected metal hypersensitivity reaction. Thus, neither necrobiosis nor infiltration of T-lymphocytes should be considered to be specific for failed metal-on-metal bearings or metal hypersensitivity reaction. Informa Healthcare 2011-10 2011-11-24 /pmc/articles/PMC3242957/ /pubmed/22112191 http://dx.doi.org/10.3109/17453674.2011.625534 Text en Copyright: © Nordic Orthopaedic Federation http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited.
spellingShingle Article
von Domarus, Christoph
Rosenberg, Jens P
Rüther, Wolfgang
Zustin, Jozef
Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties
title Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties
title_full Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties
title_fullStr Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties
title_full_unstemmed Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties
title_short Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties
title_sort necrobiosis and t-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3242957/
https://www.ncbi.nlm.nih.gov/pubmed/22112191
http://dx.doi.org/10.3109/17453674.2011.625534
work_keys_str_mv AT vondomaruschristoph necrobiosisandtlymphocyteinfiltrationinretrievedasepticallyloosenedmetalonpolyethylenearthroplasties
AT rosenbergjensp necrobiosisandtlymphocyteinfiltrationinretrievedasepticallyloosenedmetalonpolyethylenearthroplasties
AT rutherwolfgang necrobiosisandtlymphocyteinfiltrationinretrievedasepticallyloosenedmetalonpolyethylenearthroplasties
AT zustinjozef necrobiosisandtlymphocyteinfiltrationinretrievedasepticallyloosenedmetalonpolyethylenearthroplasties