Body electrical loss analysis (BELA) in the assessment of visceral fat: a demonstration

BACKGROUND: Body electrical loss analysis (BELA) is a new non-invasive way to assess visceral fat depot size through the use of electromagnetism. BELA has worked well in phantom measurements, but the technology is not yet fully validated. METHODS: Ten volunteers (5 men and 5 women, age: 22-60 y, BMI...

Descripción completa

Detalles Bibliográficos
Autores principales: Blomqvist, Kim H, Lundbom, Jesper, Lundbom, Nina, Sepponen, Raimo E
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3248862/
https://www.ncbi.nlm.nih.gov/pubmed/22074269
http://dx.doi.org/10.1186/1475-925X-10-98
_version_ 1782220280524963840
author Blomqvist, Kim H
Lundbom, Jesper
Lundbom, Nina
Sepponen, Raimo E
author_facet Blomqvist, Kim H
Lundbom, Jesper
Lundbom, Nina
Sepponen, Raimo E
author_sort Blomqvist, Kim H
collection PubMed
description BACKGROUND: Body electrical loss analysis (BELA) is a new non-invasive way to assess visceral fat depot size through the use of electromagnetism. BELA has worked well in phantom measurements, but the technology is not yet fully validated. METHODS: Ten volunteers (5 men and 5 women, age: 22-60 y, BMI: 21-30 kg/m(2), waist circumference: 73-108 cm) were measured with the BELA instrument and with cross-sectional magnetic resonance imaging (MRI) at the navel level, navel +5 cm and navel -5 cm. The BELA signal was compared with visceral and subcutaneous fat areas calculated from the MR images. RESULTS: The BELA signal did not correlate with subcutaneous fat area at any level, but correlated significantly with visceral fat area at the navel level and navel +5 cm. The correlation was best at level of navel +5 cm (R(2 )= 0.74, P < 0.005, SEE = 29.7 cm(2), LOOCV = 40.1 cm(2)), where SEE is the standard error of the estimate and LOOCV is the root mean squared error of leave-one-out style cross-validation. The average estimate of repeatability of the BELA signal observed through the study was ±9.6 %. One of the volunteers had an exceptionally large amount of visceral fat, which was underestimated by BELA. CONCLUSIONS: The correlation of the BELA signal with the visceral but not with the subcutaneous fat area as measured by MRI is promising. The lack of correlation with the subcutaneous fat suggests that subcutaneous fat has a minor influence to the BELA signal. Further research will show if it is possible to develop a reliable low-cost method for the assessment of visceral fat either using BELA only or combining it, for example, with bioelectrical impedance measurement. The combination of these measurements may help assessing visceral fat in a large scale of body composition. Before large-scale clinical testing and ROC analysis, the initial BELA instrumentation requires improvements. The accuracy of the present equipment is not sufficient for such new technology.
format Online
Article
Text
id pubmed-3248862
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-32488622012-01-03 Body electrical loss analysis (BELA) in the assessment of visceral fat: a demonstration Blomqvist, Kim H Lundbom, Jesper Lundbom, Nina Sepponen, Raimo E Biomed Eng Online Research BACKGROUND: Body electrical loss analysis (BELA) is a new non-invasive way to assess visceral fat depot size through the use of electromagnetism. BELA has worked well in phantom measurements, but the technology is not yet fully validated. METHODS: Ten volunteers (5 men and 5 women, age: 22-60 y, BMI: 21-30 kg/m(2), waist circumference: 73-108 cm) were measured with the BELA instrument and with cross-sectional magnetic resonance imaging (MRI) at the navel level, navel +5 cm and navel -5 cm. The BELA signal was compared with visceral and subcutaneous fat areas calculated from the MR images. RESULTS: The BELA signal did not correlate with subcutaneous fat area at any level, but correlated significantly with visceral fat area at the navel level and navel +5 cm. The correlation was best at level of navel +5 cm (R(2 )= 0.74, P < 0.005, SEE = 29.7 cm(2), LOOCV = 40.1 cm(2)), where SEE is the standard error of the estimate and LOOCV is the root mean squared error of leave-one-out style cross-validation. The average estimate of repeatability of the BELA signal observed through the study was ±9.6 %. One of the volunteers had an exceptionally large amount of visceral fat, which was underestimated by BELA. CONCLUSIONS: The correlation of the BELA signal with the visceral but not with the subcutaneous fat area as measured by MRI is promising. The lack of correlation with the subcutaneous fat suggests that subcutaneous fat has a minor influence to the BELA signal. Further research will show if it is possible to develop a reliable low-cost method for the assessment of visceral fat either using BELA only or combining it, for example, with bioelectrical impedance measurement. The combination of these measurements may help assessing visceral fat in a large scale of body composition. Before large-scale clinical testing and ROC analysis, the initial BELA instrumentation requires improvements. The accuracy of the present equipment is not sufficient for such new technology. BioMed Central 2011-11-10 /pmc/articles/PMC3248862/ /pubmed/22074269 http://dx.doi.org/10.1186/1475-925X-10-98 Text en Copyright ©2011 Blomqvist et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Blomqvist, Kim H
Lundbom, Jesper
Lundbom, Nina
Sepponen, Raimo E
Body electrical loss analysis (BELA) in the assessment of visceral fat: a demonstration
title Body electrical loss analysis (BELA) in the assessment of visceral fat: a demonstration
title_full Body electrical loss analysis (BELA) in the assessment of visceral fat: a demonstration
title_fullStr Body electrical loss analysis (BELA) in the assessment of visceral fat: a demonstration
title_full_unstemmed Body electrical loss analysis (BELA) in the assessment of visceral fat: a demonstration
title_short Body electrical loss analysis (BELA) in the assessment of visceral fat: a demonstration
title_sort body electrical loss analysis (bela) in the assessment of visceral fat: a demonstration
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3248862/
https://www.ncbi.nlm.nih.gov/pubmed/22074269
http://dx.doi.org/10.1186/1475-925X-10-98
work_keys_str_mv AT blomqvistkimh bodyelectricallossanalysisbelaintheassessmentofvisceralfatademonstration
AT lundbomjesper bodyelectricallossanalysisbelaintheassessmentofvisceralfatademonstration
AT lundbomnina bodyelectricallossanalysisbelaintheassessmentofvisceralfatademonstration
AT sepponenraimoe bodyelectricallossanalysisbelaintheassessmentofvisceralfatademonstration