Cargando…

Relationship between the Occurrence of Thromboembolism and INR Measurement Interval in Low Intensity Anticoagulation after Aortic Mechanical Valve Replacement

BACKGROUND: We investigated changes in the International Normalized Ratio (INR) and its measurement interval in patients with thromboembolic events who were treated by low intensity anticoagulation therapy after isolated mechanical aortic valve replacement. MATERIALS AND METHODS: Seventy-seven patie...

Descripción completa

Detalles Bibliográficos
Autores principales: Rhie, Sangho, Choi, Jun Young, Jang, In Seok, Kim, Jong Woo, Lee, Chung Eun, Park, Hyun Oh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society for Thoracic and Cardiovascular Surgery 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3249306/
https://www.ncbi.nlm.nih.gov/pubmed/22263155
http://dx.doi.org/10.5090/kjtcs.2011.44.3.220
_version_ 1782220327918501888
author Rhie, Sangho
Choi, Jun Young
Jang, In Seok
Kim, Jong Woo
Lee, Chung Eun
Park, Hyun Oh
author_facet Rhie, Sangho
Choi, Jun Young
Jang, In Seok
Kim, Jong Woo
Lee, Chung Eun
Park, Hyun Oh
author_sort Rhie, Sangho
collection PubMed
description BACKGROUND: We investigated changes in the International Normalized Ratio (INR) and its measurement interval in patients with thromboembolic events who were treated by low intensity anticoagulation therapy after isolated mechanical aortic valve replacement. MATERIALS AND METHODS: Seventy-seven patients who underwent surgery from June 1990 to September 2006 were enrolled in the study and observed until August 2008. The patients were followed up at 4~8 week intervals and their warfarin (Coumadin)® dosage was adjusted aiming for a target range of INR 1.5~2.5. The rate of thromboembolic events was obtained. Changes in the mean INR and INR measurement interval were comparatively analyzed between the normal group (event free group, N=52) who had no anticoagulation-related complications and the thromboembolic group (N=10). Hospital records were reviewed retrospectively. RESULTS: The observation period was 666.75 patient-years. Thromboembolic events occurred in 10 patients. The linearized occurrence rate of thromboembolism was 1.50%/patient-years. Actuarial thromboembolism-free rates were 97.10±2.02% at 5 years, 84.30±5.22% at 10 years, and 67.44±12.14% at 15 years. The percentages of INR within the target range and mean INR were not statistically significantly different for the normal and thromboembolic groups. However, the mean INR during the segmented period just before the events showed a significantly lower level in the thromboembolic group (during a 4 month period: normal group, 1.86±0.14 vs. thromboembolic group, 1.50±0.28, p<0.001). The mean intervals of INR measurement during the whole observation period showed no significant differences between groups, but in the segmented period just before the events, the interval was significantly longer in thromboembolic group (during a 6 month period: normal group, 49.04±9.47 days vs. thromboembolic group, 65.89±44.88 days, p<0.01). CONCLUSION: To prevent the occurrence of thromboembolic events in patients who receive isolated aortic valve replacement and low intensity anticoagulation therapy, we suggest that it would be safe to maintain an INR level above 1.8 and to measure the INR at least every 7~8 weeks.
format Online
Article
Text
id pubmed-3249306
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Korean Society for Thoracic and Cardiovascular Surgery
record_format MEDLINE/PubMed
spelling pubmed-32493062012-01-19 Relationship between the Occurrence of Thromboembolism and INR Measurement Interval in Low Intensity Anticoagulation after Aortic Mechanical Valve Replacement Rhie, Sangho Choi, Jun Young Jang, In Seok Kim, Jong Woo Lee, Chung Eun Park, Hyun Oh Korean J Thorac Cardiovasc Surg Clinical Research BACKGROUND: We investigated changes in the International Normalized Ratio (INR) and its measurement interval in patients with thromboembolic events who were treated by low intensity anticoagulation therapy after isolated mechanical aortic valve replacement. MATERIALS AND METHODS: Seventy-seven patients who underwent surgery from June 1990 to September 2006 were enrolled in the study and observed until August 2008. The patients were followed up at 4~8 week intervals and their warfarin (Coumadin)® dosage was adjusted aiming for a target range of INR 1.5~2.5. The rate of thromboembolic events was obtained. Changes in the mean INR and INR measurement interval were comparatively analyzed between the normal group (event free group, N=52) who had no anticoagulation-related complications and the thromboembolic group (N=10). Hospital records were reviewed retrospectively. RESULTS: The observation period was 666.75 patient-years. Thromboembolic events occurred in 10 patients. The linearized occurrence rate of thromboembolism was 1.50%/patient-years. Actuarial thromboembolism-free rates were 97.10±2.02% at 5 years, 84.30±5.22% at 10 years, and 67.44±12.14% at 15 years. The percentages of INR within the target range and mean INR were not statistically significantly different for the normal and thromboembolic groups. However, the mean INR during the segmented period just before the events showed a significantly lower level in the thromboembolic group (during a 4 month period: normal group, 1.86±0.14 vs. thromboembolic group, 1.50±0.28, p<0.001). The mean intervals of INR measurement during the whole observation period showed no significant differences between groups, but in the segmented period just before the events, the interval was significantly longer in thromboembolic group (during a 6 month period: normal group, 49.04±9.47 days vs. thromboembolic group, 65.89±44.88 days, p<0.01). CONCLUSION: To prevent the occurrence of thromboembolic events in patients who receive isolated aortic valve replacement and low intensity anticoagulation therapy, we suggest that it would be safe to maintain an INR level above 1.8 and to measure the INR at least every 7~8 weeks. Korean Society for Thoracic and Cardiovascular Surgery 2011-06 2011-06-11 /pmc/articles/PMC3249306/ /pubmed/22263155 http://dx.doi.org/10.5090/kjtcs.2011.44.3.220 Text en © The Korean Society for Thoracic and Cardiovascular Surgery. 2011. All right reserved. This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Research
Rhie, Sangho
Choi, Jun Young
Jang, In Seok
Kim, Jong Woo
Lee, Chung Eun
Park, Hyun Oh
Relationship between the Occurrence of Thromboembolism and INR Measurement Interval in Low Intensity Anticoagulation after Aortic Mechanical Valve Replacement
title Relationship between the Occurrence of Thromboembolism and INR Measurement Interval in Low Intensity Anticoagulation after Aortic Mechanical Valve Replacement
title_full Relationship between the Occurrence of Thromboembolism and INR Measurement Interval in Low Intensity Anticoagulation after Aortic Mechanical Valve Replacement
title_fullStr Relationship between the Occurrence of Thromboembolism and INR Measurement Interval in Low Intensity Anticoagulation after Aortic Mechanical Valve Replacement
title_full_unstemmed Relationship between the Occurrence of Thromboembolism and INR Measurement Interval in Low Intensity Anticoagulation after Aortic Mechanical Valve Replacement
title_short Relationship between the Occurrence of Thromboembolism and INR Measurement Interval in Low Intensity Anticoagulation after Aortic Mechanical Valve Replacement
title_sort relationship between the occurrence of thromboembolism and inr measurement interval in low intensity anticoagulation after aortic mechanical valve replacement
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3249306/
https://www.ncbi.nlm.nih.gov/pubmed/22263155
http://dx.doi.org/10.5090/kjtcs.2011.44.3.220
work_keys_str_mv AT rhiesangho relationshipbetweentheoccurrenceofthromboembolismandinrmeasurementintervalinlowintensityanticoagulationafteraorticmechanicalvalvereplacement
AT choijunyoung relationshipbetweentheoccurrenceofthromboembolismandinrmeasurementintervalinlowintensityanticoagulationafteraorticmechanicalvalvereplacement
AT janginseok relationshipbetweentheoccurrenceofthromboembolismandinrmeasurementintervalinlowintensityanticoagulationafteraorticmechanicalvalvereplacement
AT kimjongwoo relationshipbetweentheoccurrenceofthromboembolismandinrmeasurementintervalinlowintensityanticoagulationafteraorticmechanicalvalvereplacement
AT leechungeun relationshipbetweentheoccurrenceofthromboembolismandinrmeasurementintervalinlowintensityanticoagulationafteraorticmechanicalvalvereplacement
AT parkhyunoh relationshipbetweentheoccurrenceofthromboembolismandinrmeasurementintervalinlowintensityanticoagulationafteraorticmechanicalvalvereplacement