Cargando…

Suitability of bilateral filtering for edge-preserving noise reduction in PET

BACKGROUND: To achieve an acceptable signal-to-noise ratio (SNR) in PET images, smoothing filters (SF) are usually employed during or after image reconstruction preventing utilisation of the full intrinsic resolution of the respective scanner. Quite generally Gaussian-shaped moving average filters (...

Descripción completa

Detalles Bibliográficos
Autores principales: Hofheinz, Frank, Langner, Jens, Beuthien-Baumann, Bettina, Oehme, Liane, Steinbach, Jörg, Kotzerke, Jörg, van den Hoff, Jörg
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3250981/
https://www.ncbi.nlm.nih.gov/pubmed/22214263
http://dx.doi.org/10.1186/2191-219X-1-23
_version_ 1782220512222511104
author Hofheinz, Frank
Langner, Jens
Beuthien-Baumann, Bettina
Oehme, Liane
Steinbach, Jörg
Kotzerke, Jörg
van den Hoff, Jörg
author_facet Hofheinz, Frank
Langner, Jens
Beuthien-Baumann, Bettina
Oehme, Liane
Steinbach, Jörg
Kotzerke, Jörg
van den Hoff, Jörg
author_sort Hofheinz, Frank
collection PubMed
description BACKGROUND: To achieve an acceptable signal-to-noise ratio (SNR) in PET images, smoothing filters (SF) are usually employed during or after image reconstruction preventing utilisation of the full intrinsic resolution of the respective scanner. Quite generally Gaussian-shaped moving average filters (MAF) are used for this purpose. A potential alternative to MAF is the group of so-called bilateral filters (BF) which provide a combination of noise reduction and edge preservation thus minimising resolution deterioration of the images. We have investigated the performance of this filter type with respect to improvement of SNR, influence on spatial resolution and for derivation of SUV(max )values in target structures of varying size. METHODS: Data of ten patients with head and neck cancer were evaluated. The patients had been investigated by routine whole body scans (ECAT EXACT HR(+), Siemens, Erlangen). Tomographic images were reconstructed (OSEM 6i/16s) using a Gaussian filter (full width half maximum (FWHM): Γ(0 )= 4 mm). Image data were then post-processed with a Gaussian MAF (FWHM: Γ(M )= 7 mm) and a Gaussian BF (spatial domain: Γ(S )= 9 mm, intensity domain: Γ(I )= 2.5 SUV), respectively. Images were assessed regarding SNR as well as spatial resolution. Thirty-four lesions (volumes of about 1-100 mL) were analysed with respect to their SUV(max )values in the original as well as in the MAF and BF filtered images. RESULTS: With the chosen filter parameters both filters improved SNR approximately by a factor of two in comparison to the original data. Spatial resolution was significantly better in the BF-filtered images in comparison to MAF (MAF: 9.5 mm, BF: 6.8 mm). In MAF-filtered data, the SUV(max )was lower by 24.1 ± 9.9% compared to the original data and showed a strong size dependency. In the BF-filtered data, the SUV(max )was lower by 4.6 ± 3.7% and no size effects were observed. CONCLUSION: Bilateral filtering allows to increase the SNR of PET image data while preserving spatial resolution and preventing smoothing-induced underestimation of SUV(max )values in small lesions. Bilateral filtering seems a promising and superior alternative to standard smoothing filters.
format Online
Article
Text
id pubmed-3250981
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Springer
record_format MEDLINE/PubMed
spelling pubmed-32509812012-02-03 Suitability of bilateral filtering for edge-preserving noise reduction in PET Hofheinz, Frank Langner, Jens Beuthien-Baumann, Bettina Oehme, Liane Steinbach, Jörg Kotzerke, Jörg van den Hoff, Jörg EJNMMI Res Original Research BACKGROUND: To achieve an acceptable signal-to-noise ratio (SNR) in PET images, smoothing filters (SF) are usually employed during or after image reconstruction preventing utilisation of the full intrinsic resolution of the respective scanner. Quite generally Gaussian-shaped moving average filters (MAF) are used for this purpose. A potential alternative to MAF is the group of so-called bilateral filters (BF) which provide a combination of noise reduction and edge preservation thus minimising resolution deterioration of the images. We have investigated the performance of this filter type with respect to improvement of SNR, influence on spatial resolution and for derivation of SUV(max )values in target structures of varying size. METHODS: Data of ten patients with head and neck cancer were evaluated. The patients had been investigated by routine whole body scans (ECAT EXACT HR(+), Siemens, Erlangen). Tomographic images were reconstructed (OSEM 6i/16s) using a Gaussian filter (full width half maximum (FWHM): Γ(0 )= 4 mm). Image data were then post-processed with a Gaussian MAF (FWHM: Γ(M )= 7 mm) and a Gaussian BF (spatial domain: Γ(S )= 9 mm, intensity domain: Γ(I )= 2.5 SUV), respectively. Images were assessed regarding SNR as well as spatial resolution. Thirty-four lesions (volumes of about 1-100 mL) were analysed with respect to their SUV(max )values in the original as well as in the MAF and BF filtered images. RESULTS: With the chosen filter parameters both filters improved SNR approximately by a factor of two in comparison to the original data. Spatial resolution was significantly better in the BF-filtered images in comparison to MAF (MAF: 9.5 mm, BF: 6.8 mm). In MAF-filtered data, the SUV(max )was lower by 24.1 ± 9.9% compared to the original data and showed a strong size dependency. In the BF-filtered data, the SUV(max )was lower by 4.6 ± 3.7% and no size effects were observed. CONCLUSION: Bilateral filtering allows to increase the SNR of PET image data while preserving spatial resolution and preventing smoothing-induced underestimation of SUV(max )values in small lesions. Bilateral filtering seems a promising and superior alternative to standard smoothing filters. Springer 2011-10-05 /pmc/articles/PMC3250981/ /pubmed/22214263 http://dx.doi.org/10.1186/2191-219X-1-23 Text en Copyright © 2011 Hofheinz et al; licensee Springer. https://creativecommons.org/licenses/by/2.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0 (https://creativecommons.org/licenses/by/2.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Hofheinz, Frank
Langner, Jens
Beuthien-Baumann, Bettina
Oehme, Liane
Steinbach, Jörg
Kotzerke, Jörg
van den Hoff, Jörg
Suitability of bilateral filtering for edge-preserving noise reduction in PET
title Suitability of bilateral filtering for edge-preserving noise reduction in PET
title_full Suitability of bilateral filtering for edge-preserving noise reduction in PET
title_fullStr Suitability of bilateral filtering for edge-preserving noise reduction in PET
title_full_unstemmed Suitability of bilateral filtering for edge-preserving noise reduction in PET
title_short Suitability of bilateral filtering for edge-preserving noise reduction in PET
title_sort suitability of bilateral filtering for edge-preserving noise reduction in pet
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3250981/
https://www.ncbi.nlm.nih.gov/pubmed/22214263
http://dx.doi.org/10.1186/2191-219X-1-23
work_keys_str_mv AT hofheinzfrank suitabilityofbilateralfilteringforedgepreservingnoisereductioninpet
AT langnerjens suitabilityofbilateralfilteringforedgepreservingnoisereductioninpet
AT beuthienbaumannbettina suitabilityofbilateralfilteringforedgepreservingnoisereductioninpet
AT oehmeliane suitabilityofbilateralfilteringforedgepreservingnoisereductioninpet
AT steinbachjorg suitabilityofbilateralfilteringforedgepreservingnoisereductioninpet
AT kotzerkejorg suitabilityofbilateralfilteringforedgepreservingnoisereductioninpet
AT vandenhoffjorg suitabilityofbilateralfilteringforedgepreservingnoisereductioninpet