Cargando…
Microbiological safety and cost-effectiveness of weekly breathing circuit changes in combination with heat moisture exchange filters: a prospective longitudinal clinical survey
Aim: To assess the safety and cost effectiveness of a usage for seven days of breathing circuit systems (BCSs) in combination with heat moisture exchanger filters (HMEF) in operation room anesthesia. Method: In a prospective longitudinal clinical study, the contamination on high-risk surfaces (HMEF...
Autores principales: | Hübner, Nils-Olaf, Daeschlein, Georg, Lehmann, Christian, Musatkin, Sergei, Kohlheim, Ute, Gibb, Andreas, Assadian, Ojan, Kobayashi, Hiroyoshi |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
German Medical Science GMS Publishing House
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3252668/ https://www.ncbi.nlm.nih.gov/pubmed/22242096 http://dx.doi.org/10.3205/dgkh000172 |
Ejemplares similares
-
Defective heat moisture exchange filter causing ‘block’ in anaesthesia breathing circuit
por: Kapoor, Hemlata, et al.
Publicado: (2016) -
Infection prevention during anaesthesia ventilation by the use of breathing system filters (BSF): Joint recommendation by German Society of Hospital Hygiene (DGKH) and German Society for Anaesthesiology and Intensive Care (DGAI)
por: Kramer, Axel, et al.
Publicado: (2010) -
Bacterial contamination of anesthesia machines’ internal breathing-circuit-systems
por: Spertini, Verena, et al.
Publicado: (2011) -
Review of indicators for cross-sectoral optimization of nosocomial infection prophylaxis – a perspective from structurally- and process-oriented hygiene
por: Hübner, Nils-Olaf, et al.
Publicado: (2012) -
Evaluation of errors and limits of the 63-μm house-dust-fraction method, a surrogate to predict hidden moisture damage
por: Baudisch, Christoph, et al.
Publicado: (2009)