Cargando…
Influence of a prophylaxis paste on surface roughness of different composites, porcelain, enamel and dentin surfaces
OBJECTIVE: To investigate the effect of a prophylaxis paste on surface roughness of different composites, enamel, dentin and porcelain surfaces. METHODS: Three different composites (FiltekZ250/Group1, Filtek Supreme XT/Group2, Premise/Group3), enamel/Group4, dentin/Group5 and porcelain/Group6 sample...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dental Investigations Society
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3252807/ https://www.ncbi.nlm.nih.gov/pubmed/22229001 |
_version_ | 1782220677224333312 |
---|---|
author | Yurdaguven, Haktan Aykor, Arzu Ozel, Emre Sabuncu, Hilmi Soyman, Mubin |
author_facet | Yurdaguven, Haktan Aykor, Arzu Ozel, Emre Sabuncu, Hilmi Soyman, Mubin |
author_sort | Yurdaguven, Haktan |
collection | PubMed |
description | OBJECTIVE: To investigate the effect of a prophylaxis paste on surface roughness of different composites, enamel, dentin and porcelain surfaces. METHODS: Three different composites (FiltekZ250/Group1, Filtek Supreme XT/Group2, Premise/Group3), enamel/Group4, dentin/Group5 and porcelain/Group6 samples were used in this study. All specimens were prepared flat by SiC discs and polished with a diamond polishing paste. The surface roughness measurements were determined with a profilometer after polishing (initial surface roughness). Prophylaxis paste was applied to the samples for 12 seconds, renewing every 6 seconds. After cleaning the samples, roughness values were measured again. Data were analyzed by Kruskal Wallis and Dunn’s multiple comparison test. Wilcoxon test was performed for the comparison of the initial and final surface roughness values (P<.05). The results were evaluated within the P<.05 confidence level. RESULTS: The initial and final surface roughness values (μm) were determined as follows: Group1: 0.039±0.009 and 0.157±0.018, Group2: 0.023±0.005 and 0.145±0.027, Group3: 0.028±0.008 and 0.109±0.012, Group4: 0.024±0.006 and 0.071±0.015, Group5: 0.030±0.007 and 0.143±0.029, Group6: 0.024±0.006 and 0.064±0.014. Significant difference was determined between the initial and final values for all groups. CONCLUSIONS: Composite and dentin surfaces were more affected by the application of prophylaxis paste than enamel and porcelain surfaces. The prophylaxis paste increased the surface roughness of all groups, but did not reach the bacterial retention roughness rate of 0.2μm. |
format | Online Article Text |
id | pubmed-3252807 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Dental Investigations Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-32528072012-01-06 Influence of a prophylaxis paste on surface roughness of different composites, porcelain, enamel and dentin surfaces Yurdaguven, Haktan Aykor, Arzu Ozel, Emre Sabuncu, Hilmi Soyman, Mubin Eur J Dent Original Articles OBJECTIVE: To investigate the effect of a prophylaxis paste on surface roughness of different composites, enamel, dentin and porcelain surfaces. METHODS: Three different composites (FiltekZ250/Group1, Filtek Supreme XT/Group2, Premise/Group3), enamel/Group4, dentin/Group5 and porcelain/Group6 samples were used in this study. All specimens were prepared flat by SiC discs and polished with a diamond polishing paste. The surface roughness measurements were determined with a profilometer after polishing (initial surface roughness). Prophylaxis paste was applied to the samples for 12 seconds, renewing every 6 seconds. After cleaning the samples, roughness values were measured again. Data were analyzed by Kruskal Wallis and Dunn’s multiple comparison test. Wilcoxon test was performed for the comparison of the initial and final surface roughness values (P<.05). The results were evaluated within the P<.05 confidence level. RESULTS: The initial and final surface roughness values (μm) were determined as follows: Group1: 0.039±0.009 and 0.157±0.018, Group2: 0.023±0.005 and 0.145±0.027, Group3: 0.028±0.008 and 0.109±0.012, Group4: 0.024±0.006 and 0.071±0.015, Group5: 0.030±0.007 and 0.143±0.029, Group6: 0.024±0.006 and 0.064±0.014. Significant difference was determined between the initial and final values for all groups. CONCLUSIONS: Composite and dentin surfaces were more affected by the application of prophylaxis paste than enamel and porcelain surfaces. The prophylaxis paste increased the surface roughness of all groups, but did not reach the bacterial retention roughness rate of 0.2μm. Dental Investigations Society 2012-01 /pmc/articles/PMC3252807/ /pubmed/22229001 Text en Copyright 2012 European Journal of Dentistry. All rights reserved. |
spellingShingle | Original Articles Yurdaguven, Haktan Aykor, Arzu Ozel, Emre Sabuncu, Hilmi Soyman, Mubin Influence of a prophylaxis paste on surface roughness of different composites, porcelain, enamel and dentin surfaces |
title | Influence of a prophylaxis paste on surface roughness of different composites, porcelain, enamel and dentin surfaces |
title_full | Influence of a prophylaxis paste on surface roughness of different composites, porcelain, enamel and dentin surfaces |
title_fullStr | Influence of a prophylaxis paste on surface roughness of different composites, porcelain, enamel and dentin surfaces |
title_full_unstemmed | Influence of a prophylaxis paste on surface roughness of different composites, porcelain, enamel and dentin surfaces |
title_short | Influence of a prophylaxis paste on surface roughness of different composites, porcelain, enamel and dentin surfaces |
title_sort | influence of a prophylaxis paste on surface roughness of different composites, porcelain, enamel and dentin surfaces |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3252807/ https://www.ncbi.nlm.nih.gov/pubmed/22229001 |
work_keys_str_mv | AT yurdaguvenhaktan influenceofaprophylaxispasteonsurfaceroughnessofdifferentcompositesporcelainenamelanddentinsurfaces AT aykorarzu influenceofaprophylaxispasteonsurfaceroughnessofdifferentcompositesporcelainenamelanddentinsurfaces AT ozelemre influenceofaprophylaxispasteonsurfaceroughnessofdifferentcompositesporcelainenamelanddentinsurfaces AT sabuncuhilmi influenceofaprophylaxispasteonsurfaceroughnessofdifferentcompositesporcelainenamelanddentinsurfaces AT soymanmubin influenceofaprophylaxispasteonsurfaceroughnessofdifferentcompositesporcelainenamelanddentinsurfaces |