Cargando…

Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents

PURPOSE: To validate the Dinamap ProCare 200 blood pressure (BP) monitor against a mercury sphygmomanometer in children 7 to 18 years old in accordance with the 2010 International Protocol of European Society of Hypertension (ESH-IP2) and the British Hypertension Society (BHS) protocol. METHODS: For...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Chong Guk, Park, Hyang Mi, Shin, Hye Jung, Moon, Jin Soo, Hong, Yeong Mi, Kim, Nam Soo, Ha, Il Soo, Chang, Myeong Jin, Oh, Kyeong Won
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Pediatric Society 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3254892/
https://www.ncbi.nlm.nih.gov/pubmed/22253643
http://dx.doi.org/10.3345/kjp.2011.54.11.463
_version_ 1782220918899081216
author Lee, Chong Guk
Park, Hyang Mi
Shin, Hye Jung
Moon, Jin Soo
Hong, Yeong Mi
Kim, Nam Soo
Ha, Il Soo
Chang, Myeong Jin
Oh, Kyeong Won
author_facet Lee, Chong Guk
Park, Hyang Mi
Shin, Hye Jung
Moon, Jin Soo
Hong, Yeong Mi
Kim, Nam Soo
Ha, Il Soo
Chang, Myeong Jin
Oh, Kyeong Won
author_sort Lee, Chong Guk
collection PubMed
description PURPOSE: To validate the Dinamap ProCare 200 blood pressure (BP) monitor against a mercury sphygmomanometer in children 7 to 18 years old in accordance with the 2010 International Protocol of European Society of Hypertension (ESH-IP2) and the British Hypertension Society (BHS) protocol. METHODS: Forty-five children were recruited for the study. A validation procedure was performed following the protocol based on the ESH-IP2 and BHS protocols for children and adolescents. Each subject underwent 7 sequential BP measurements alternatively with a mercury sphygmomanometer and the test device by trained nurses. The results were analyzed according to the validation criteria of ESH-IP2. RESULTS: The mean (±SD) difference in the absolute BP values between test device and mercury sphygmomanometer readings was 1.85±1.65 mmHg for systolic BP (SBP) and 4.41±3.53 mmHg for diastolic BP (DBP). These results fulfilled the Association for the Advancement of Medical Instrumentation criterion of a mean±SD below 5±8 mmHg for both SBP and DBP. The percentages of test device-observer mercury sphygmomanometer BP differences within 5, 10, and 15 mmHg were 96%, 100%, and 100% for SBP, and 69%, 92%, and 100% for DBP, respectively, in the part 1 analysis; both SBP and DBP passed the part 1 criteria. In the part 2 analysis, SBP passed the criteria but DBP failed. CONCLUSION: Although the Dinamap ProCare 200 BP monitor failed an adapted ESH-IP2, SBP passed. When comparing BP readings measured by oscillometers and mercury sphygmomanometers, one has to consider the differences between them, particularly in DBP, because DBP can be underestimated.
format Online
Article
Text
id pubmed-3254892
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher The Korean Pediatric Society
record_format MEDLINE/PubMed
spelling pubmed-32548922012-01-17 Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents Lee, Chong Guk Park, Hyang Mi Shin, Hye Jung Moon, Jin Soo Hong, Yeong Mi Kim, Nam Soo Ha, Il Soo Chang, Myeong Jin Oh, Kyeong Won Korean J Pediatr Original Article PURPOSE: To validate the Dinamap ProCare 200 blood pressure (BP) monitor against a mercury sphygmomanometer in children 7 to 18 years old in accordance with the 2010 International Protocol of European Society of Hypertension (ESH-IP2) and the British Hypertension Society (BHS) protocol. METHODS: Forty-five children were recruited for the study. A validation procedure was performed following the protocol based on the ESH-IP2 and BHS protocols for children and adolescents. Each subject underwent 7 sequential BP measurements alternatively with a mercury sphygmomanometer and the test device by trained nurses. The results were analyzed according to the validation criteria of ESH-IP2. RESULTS: The mean (±SD) difference in the absolute BP values between test device and mercury sphygmomanometer readings was 1.85±1.65 mmHg for systolic BP (SBP) and 4.41±3.53 mmHg for diastolic BP (DBP). These results fulfilled the Association for the Advancement of Medical Instrumentation criterion of a mean±SD below 5±8 mmHg for both SBP and DBP. The percentages of test device-observer mercury sphygmomanometer BP differences within 5, 10, and 15 mmHg were 96%, 100%, and 100% for SBP, and 69%, 92%, and 100% for DBP, respectively, in the part 1 analysis; both SBP and DBP passed the part 1 criteria. In the part 2 analysis, SBP passed the criteria but DBP failed. CONCLUSION: Although the Dinamap ProCare 200 BP monitor failed an adapted ESH-IP2, SBP passed. When comparing BP readings measured by oscillometers and mercury sphygmomanometers, one has to consider the differences between them, particularly in DBP, because DBP can be underestimated. The Korean Pediatric Society 2011-11 2011-11-30 /pmc/articles/PMC3254892/ /pubmed/22253643 http://dx.doi.org/10.3345/kjp.2011.54.11.463 Text en Copyright © 2011 by The Korean Pediatric Society http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Chong Guk
Park, Hyang Mi
Shin, Hye Jung
Moon, Jin Soo
Hong, Yeong Mi
Kim, Nam Soo
Ha, Il Soo
Chang, Myeong Jin
Oh, Kyeong Won
Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
title Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
title_full Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
title_fullStr Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
title_full_unstemmed Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
title_short Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
title_sort validation study of the dinamap procare 200 upper arm blood pressure monitor in children and adolescents
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3254892/
https://www.ncbi.nlm.nih.gov/pubmed/22253643
http://dx.doi.org/10.3345/kjp.2011.54.11.463
work_keys_str_mv AT leechongguk validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT parkhyangmi validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT shinhyejung validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT moonjinsoo validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT hongyeongmi validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT kimnamsoo validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT hailsoo validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT changmyeongjin validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT ohkyeongwon validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents