Cargando…

Capsule Endoscopy in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators: (Re)evaluation of the Current State in Germany, Austria, and Switzerland 2010

Background and Aims. The study was a repeated evaluation of the experience of capsule endoscopy (CE) in patients with cardiac pacemaker or implantable cardioverter defibrillator (ICD). Patients and Methods. A standardized questionnaire was sent by the manufactors Given Imaging and Olympus to all cen...

Descripción completa

Detalles Bibliográficos
Autores principales: Bandorski, Dirk, Jakobs, Ralf, Brück, Martin, Hoeltgen, Reinhard, Wieczorek, Marcus, Keuchel, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3255108/
https://www.ncbi.nlm.nih.gov/pubmed/22253620
http://dx.doi.org/10.1155/2012/717408
_version_ 1782220962969681920
author Bandorski, Dirk
Jakobs, Ralf
Brück, Martin
Hoeltgen, Reinhard
Wieczorek, Marcus
Keuchel, Martin
author_facet Bandorski, Dirk
Jakobs, Ralf
Brück, Martin
Hoeltgen, Reinhard
Wieczorek, Marcus
Keuchel, Martin
author_sort Bandorski, Dirk
collection PubMed
description Background and Aims. The study was a repeated evaluation of the experience of capsule endoscopy (CE) in patients with cardiac pacemaker or implantable cardioverter defibrillator (ICD). Patients and Methods. A standardized questionnaire was sent by the manufactors Given Imaging and Olympus to all centers in Germany, Austria, and Switzerland providing capsule endoscopy service. The questionnaire covers the number of examined patients, monitoring during CE, check of the electric implants before and after CE, occurrence of arrhythmia, quality of CE video, complications, indication of CE, and type of institution. Results. Overall 580 questionnaires were sent to the users. 26/5% (Germany/Austria + Switzerland) of the questionnaires were sent back anonymously to the authors. 114 centers (82 hospitals, 11 surgeries, 21 without specification) replied. In 58 centers (51%), patients with cardiac pacemaker (n = 300) and ICDs (n = 80) underwent uneventful capsule endoscopy. The predominant indication (patients with CP 97%, patients with ICD 100%) was mid gastrointestinal bleeding. Conclusion. The results of our inquiry show that in spite of formal contraindication CE is increasingly applied in bleeding patients with cardiac pacemakers/ICDs and seems to be safe even in a large cohort.
format Online
Article
Text
id pubmed-3255108
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-32551082012-01-17 Capsule Endoscopy in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators: (Re)evaluation of the Current State in Germany, Austria, and Switzerland 2010 Bandorski, Dirk Jakobs, Ralf Brück, Martin Hoeltgen, Reinhard Wieczorek, Marcus Keuchel, Martin Gastroenterol Res Pract Clinical Study Background and Aims. The study was a repeated evaluation of the experience of capsule endoscopy (CE) in patients with cardiac pacemaker or implantable cardioverter defibrillator (ICD). Patients and Methods. A standardized questionnaire was sent by the manufactors Given Imaging and Olympus to all centers in Germany, Austria, and Switzerland providing capsule endoscopy service. The questionnaire covers the number of examined patients, monitoring during CE, check of the electric implants before and after CE, occurrence of arrhythmia, quality of CE video, complications, indication of CE, and type of institution. Results. Overall 580 questionnaires were sent to the users. 26/5% (Germany/Austria + Switzerland) of the questionnaires were sent back anonymously to the authors. 114 centers (82 hospitals, 11 surgeries, 21 without specification) replied. In 58 centers (51%), patients with cardiac pacemaker (n = 300) and ICDs (n = 80) underwent uneventful capsule endoscopy. The predominant indication (patients with CP 97%, patients with ICD 100%) was mid gastrointestinal bleeding. Conclusion. The results of our inquiry show that in spite of formal contraindication CE is increasingly applied in bleeding patients with cardiac pacemakers/ICDs and seems to be safe even in a large cohort. Hindawi Publishing Corporation 2012 2011-12-29 /pmc/articles/PMC3255108/ /pubmed/22253620 http://dx.doi.org/10.1155/2012/717408 Text en Copyright © 2012 Dirk Bandorski et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Bandorski, Dirk
Jakobs, Ralf
Brück, Martin
Hoeltgen, Reinhard
Wieczorek, Marcus
Keuchel, Martin
Capsule Endoscopy in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators: (Re)evaluation of the Current State in Germany, Austria, and Switzerland 2010
title Capsule Endoscopy in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators: (Re)evaluation of the Current State in Germany, Austria, and Switzerland 2010
title_full Capsule Endoscopy in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators: (Re)evaluation of the Current State in Germany, Austria, and Switzerland 2010
title_fullStr Capsule Endoscopy in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators: (Re)evaluation of the Current State in Germany, Austria, and Switzerland 2010
title_full_unstemmed Capsule Endoscopy in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators: (Re)evaluation of the Current State in Germany, Austria, and Switzerland 2010
title_short Capsule Endoscopy in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators: (Re)evaluation of the Current State in Germany, Austria, and Switzerland 2010
title_sort capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter defibrillators: (re)evaluation of the current state in germany, austria, and switzerland 2010
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3255108/
https://www.ncbi.nlm.nih.gov/pubmed/22253620
http://dx.doi.org/10.1155/2012/717408
work_keys_str_mv AT bandorskidirk capsuleendoscopyinpatientswithcardiacpacemakersandimplantablecardioverterdefibrillatorsreevaluationofthecurrentstateingermanyaustriaandswitzerland2010
AT jakobsralf capsuleendoscopyinpatientswithcardiacpacemakersandimplantablecardioverterdefibrillatorsreevaluationofthecurrentstateingermanyaustriaandswitzerland2010
AT bruckmartin capsuleendoscopyinpatientswithcardiacpacemakersandimplantablecardioverterdefibrillatorsreevaluationofthecurrentstateingermanyaustriaandswitzerland2010
AT hoeltgenreinhard capsuleendoscopyinpatientswithcardiacpacemakersandimplantablecardioverterdefibrillatorsreevaluationofthecurrentstateingermanyaustriaandswitzerland2010
AT wieczorekmarcus capsuleendoscopyinpatientswithcardiacpacemakersandimplantablecardioverterdefibrillatorsreevaluationofthecurrentstateingermanyaustriaandswitzerland2010
AT keuchelmartin capsuleendoscopyinpatientswithcardiacpacemakersandimplantablecardioverterdefibrillatorsreevaluationofthecurrentstateingermanyaustriaandswitzerland2010