Cargando…
Phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics
The cone photoreceptor’s outer segment (OS) experiences changes in optical path length, both in response to visible stimuli and as a matter of its daily course of renewal and shedding. These changes are of interest, to quantify function in healthy cells and assess dysfunction in diseased ones. While...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3255329/ https://www.ncbi.nlm.nih.gov/pubmed/22254172 http://dx.doi.org/10.1364/BOE.3.000104 |
_version_ | 1782220983033135104 |
---|---|
author | Jonnal, Ravi S. Kocaoglu, Omer P. Wang, Qiang Lee, Sangyeol Miller, Donald T. |
author_facet | Jonnal, Ravi S. Kocaoglu, Omer P. Wang, Qiang Lee, Sangyeol Miller, Donald T. |
author_sort | Jonnal, Ravi S. |
collection | PubMed |
description | The cone photoreceptor’s outer segment (OS) experiences changes in optical path length, both in response to visible stimuli and as a matter of its daily course of renewal and shedding. These changes are of interest, to quantify function in healthy cells and assess dysfunction in diseased ones. While optical coherence tomography (OCT), combined with adaptive optics (AO), has permitted unprecedented three-dimensional resolution in the living retina, it has not generally been able to measure these OS dynamics, whose scale is smaller than OCT’s axial resolution of a few microns. A possible solution is to take advantage of the phase information encoded in the OCT signal. Phase-sensitive implementations of spectral-domain optical coherence tomography (SD-OCT) have been demonstrated, capable of resolving sample axial displacements much smaller than the imaging wavelength, but these have been limited to ex vivo samples. In this paper we present a novel technique for retrieving phase information from OCT volumes of the outer retina. The key component of our technique is quantification of phase differences within the retina. We provide a quantitative analysis of such phase information and show that–when combined with appropriate methods for filtering and unwrapping–it can improve the sensitivity to OS length change by more than an order of magnitude, down to 45 nm, slightly thicker than a single OS disc. We further show that phase sensitivity drops off with retinal eccentricity, and that the best location for phase imaging is close to the fovea. We apply the technique to the measurement of sub-resolution changes in the OS over matters of hours. Using custom software for registration and tracking, these microscopic changes are monitored in hundreds of cones over time. In two subjects, the OS was found to have average elongation rates of 150 nm/hr, values which agree with our previous findings. |
format | Online Article Text |
id | pubmed-3255329 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-32553292012-01-17 Phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics Jonnal, Ravi S. Kocaoglu, Omer P. Wang, Qiang Lee, Sangyeol Miller, Donald T. Biomed Opt Express Optical Coherence Tomography The cone photoreceptor’s outer segment (OS) experiences changes in optical path length, both in response to visible stimuli and as a matter of its daily course of renewal and shedding. These changes are of interest, to quantify function in healthy cells and assess dysfunction in diseased ones. While optical coherence tomography (OCT), combined with adaptive optics (AO), has permitted unprecedented three-dimensional resolution in the living retina, it has not generally been able to measure these OS dynamics, whose scale is smaller than OCT’s axial resolution of a few microns. A possible solution is to take advantage of the phase information encoded in the OCT signal. Phase-sensitive implementations of spectral-domain optical coherence tomography (SD-OCT) have been demonstrated, capable of resolving sample axial displacements much smaller than the imaging wavelength, but these have been limited to ex vivo samples. In this paper we present a novel technique for retrieving phase information from OCT volumes of the outer retina. The key component of our technique is quantification of phase differences within the retina. We provide a quantitative analysis of such phase information and show that–when combined with appropriate methods for filtering and unwrapping–it can improve the sensitivity to OS length change by more than an order of magnitude, down to 45 nm, slightly thicker than a single OS disc. We further show that phase sensitivity drops off with retinal eccentricity, and that the best location for phase imaging is close to the fovea. We apply the technique to the measurement of sub-resolution changes in the OS over matters of hours. Using custom software for registration and tracking, these microscopic changes are monitored in hundreds of cones over time. In two subjects, the OS was found to have average elongation rates of 150 nm/hr, values which agree with our previous findings. Optical Society of America 2011-12-13 /pmc/articles/PMC3255329/ /pubmed/22254172 http://dx.doi.org/10.1364/BOE.3.000104 Text en © 2011 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
spellingShingle | Optical Coherence Tomography Jonnal, Ravi S. Kocaoglu, Omer P. Wang, Qiang Lee, Sangyeol Miller, Donald T. Phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics |
title | Phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics |
title_full | Phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics |
title_fullStr | Phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics |
title_full_unstemmed | Phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics |
title_short | Phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics |
title_sort | phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics |
topic | Optical Coherence Tomography |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3255329/ https://www.ncbi.nlm.nih.gov/pubmed/22254172 http://dx.doi.org/10.1364/BOE.3.000104 |
work_keys_str_mv | AT jonnalravis phasesensitiveimagingoftheouterretinausingopticalcoherencetomographyandadaptiveoptics AT kocaogluomerp phasesensitiveimagingoftheouterretinausingopticalcoherencetomographyandadaptiveoptics AT wangqiang phasesensitiveimagingoftheouterretinausingopticalcoherencetomographyandadaptiveoptics AT leesangyeol phasesensitiveimagingoftheouterretinausingopticalcoherencetomographyandadaptiveoptics AT millerdonaldt phasesensitiveimagingoftheouterretinausingopticalcoherencetomographyandadaptiveoptics |