Visual performance of the Tecnis one-piece lens ZCB00

SYNOPSIS: The aspheric, one-piece design of the Tecnis(®) ZCB00 intraocular lens provided higher mesopic contrast sensitivity and relatively constant refraction at different pupil sizes compared to the Sensar(®) AR40e. PURPOSE: Comparing the impact on functional vision of the aspheric Tecnis(®) ZCB0...

Descripción completa

Detalles Bibliográficos
Autores principales: Wahba, Sherein S, Riad, Riad F, Morkos, Fathy F, Hassouna, Abdallah K, Roshdy, Maged M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3258090/
https://www.ncbi.nlm.nih.gov/pubmed/22267915
http://dx.doi.org/10.2147/OPTH.S27324
_version_ 1782221227567349760
author Wahba, Sherein S
Riad, Riad F
Morkos, Fathy F
Hassouna, Abdallah K
Roshdy, Maged M
author_facet Wahba, Sherein S
Riad, Riad F
Morkos, Fathy F
Hassouna, Abdallah K
Roshdy, Maged M
author_sort Wahba, Sherein S
collection PubMed
description SYNOPSIS: The aspheric, one-piece design of the Tecnis(®) ZCB00 intraocular lens provided higher mesopic contrast sensitivity and relatively constant refraction at different pupil sizes compared to the Sensar(®) AR40e. PURPOSE: Comparing the impact on functional vision of the aspheric Tecnis(®) ZCB00 one-piece lens compared to the spherical Sensar(®) AR40e three-piece lens. SETTING: National Eye Hospital, Cairo, Egypt. METHODS: In this prospective study, we implanted 32 Tecnis ZCB00 (Abbott Medical Optics, Santa Ana, CA) and 30 Sensar AR40e (Pharamacia and Upjohn LLC, North Peapack, NJ) lenses. Twenty-three patients in the ZCB00 group and 13 patients in the AR40e group provided reliable, reproducible data, and were therefore included in the statistical analysis. After 8 weeks, we measured photopic contrast sensitivity (PCS) at 85 cd/m(2) and mesopic contrast sensitivity (MCS) at 5 cd/m(2). Uncorrected and best-corrected visual acuity were measured. Myopic shift was analyzed by comparing the manifest refraction spherical equivalent at 3 days and 8 weeks after surgery in the normal and dilated pupil. RESULTS: The Tecnis ZCB00 group showed significantly better MCS than the Sensar AR40e group at a spatial frequency of six cycles per degree (cpd) (P = 0.037), but not at 3, 12, or 18 cpd (P = 0.299, P = 0.226, and P = 0.396, respectively). There were no significant differences between groups in corrected distance visual acuity (P = 0.175) or PCS at 3, 6, 12, or 18 cpd spatial frequencies (P = 0.440, P = 0.176, P = 0.365, and P = 0.251, respectively). The ZCB00 group showed less myopic shift in normal and dilated pupils between 3 days and 8 weeks after surgery compared to the AR40e group, but this difference was not significant. CONCLUSION: The Tecnis one-piece ZCB00 provided higher MCS at moderate spatial frequency than the three-piece Sensar AR40e, and was associated with relatively constant refraction at different pupil sizes.
format Online
Article
Text
id pubmed-3258090
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-32580902012-01-20 Visual performance of the Tecnis one-piece lens ZCB00 Wahba, Sherein S Riad, Riad F Morkos, Fathy F Hassouna, Abdallah K Roshdy, Maged M Clin Ophthalmol Original Research SYNOPSIS: The aspheric, one-piece design of the Tecnis(®) ZCB00 intraocular lens provided higher mesopic contrast sensitivity and relatively constant refraction at different pupil sizes compared to the Sensar(®) AR40e. PURPOSE: Comparing the impact on functional vision of the aspheric Tecnis(®) ZCB00 one-piece lens compared to the spherical Sensar(®) AR40e three-piece lens. SETTING: National Eye Hospital, Cairo, Egypt. METHODS: In this prospective study, we implanted 32 Tecnis ZCB00 (Abbott Medical Optics, Santa Ana, CA) and 30 Sensar AR40e (Pharamacia and Upjohn LLC, North Peapack, NJ) lenses. Twenty-three patients in the ZCB00 group and 13 patients in the AR40e group provided reliable, reproducible data, and were therefore included in the statistical analysis. After 8 weeks, we measured photopic contrast sensitivity (PCS) at 85 cd/m(2) and mesopic contrast sensitivity (MCS) at 5 cd/m(2). Uncorrected and best-corrected visual acuity were measured. Myopic shift was analyzed by comparing the manifest refraction spherical equivalent at 3 days and 8 weeks after surgery in the normal and dilated pupil. RESULTS: The Tecnis ZCB00 group showed significantly better MCS than the Sensar AR40e group at a spatial frequency of six cycles per degree (cpd) (P = 0.037), but not at 3, 12, or 18 cpd (P = 0.299, P = 0.226, and P = 0.396, respectively). There were no significant differences between groups in corrected distance visual acuity (P = 0.175) or PCS at 3, 6, 12, or 18 cpd spatial frequencies (P = 0.440, P = 0.176, P = 0.365, and P = 0.251, respectively). The ZCB00 group showed less myopic shift in normal and dilated pupils between 3 days and 8 weeks after surgery compared to the AR40e group, but this difference was not significant. CONCLUSION: The Tecnis one-piece ZCB00 provided higher MCS at moderate spatial frequency than the three-piece Sensar AR40e, and was associated with relatively constant refraction at different pupil sizes. Dove Medical Press 2011 2011-12-23 /pmc/articles/PMC3258090/ /pubmed/22267915 http://dx.doi.org/10.2147/OPTH.S27324 Text en © 2011 Wahba et al, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Wahba, Sherein S
Riad, Riad F
Morkos, Fathy F
Hassouna, Abdallah K
Roshdy, Maged M
Visual performance of the Tecnis one-piece lens ZCB00
title Visual performance of the Tecnis one-piece lens ZCB00
title_full Visual performance of the Tecnis one-piece lens ZCB00
title_fullStr Visual performance of the Tecnis one-piece lens ZCB00
title_full_unstemmed Visual performance of the Tecnis one-piece lens ZCB00
title_short Visual performance of the Tecnis one-piece lens ZCB00
title_sort visual performance of the tecnis one-piece lens zcb00
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3258090/
https://www.ncbi.nlm.nih.gov/pubmed/22267915
http://dx.doi.org/10.2147/OPTH.S27324
work_keys_str_mv AT wahbashereins visualperformanceofthetecnisonepiecelenszcb00
AT riadriadf visualperformanceofthetecnisonepiecelenszcb00
AT morkosfathyf visualperformanceofthetecnisonepiecelenszcb00
AT hassounaabdallahk visualperformanceofthetecnisonepiecelenszcb00
AT roshdymagedm visualperformanceofthetecnisonepiecelenszcb00